Selection of Transcatheter Heart vaLve With Intermediate Sizing in Patients With Severe Aortic Stenosis Treated With Transcatheter Aortic Valve Replacement (SELECT TAVR)

Selection of transcathEter Heart vaLve With intermEdiate Sizing in Patients With Severe aortiC Stenosis Treated With Transcatheter Aortic Valve Replacement

Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.

The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.

Objectives:

The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.

Study design:

The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.

Study population:

The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges

Studieoversigt

Status

Ikke rekrutterer endnu

Intervention / Behandling

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

604

Fase

  • Fase 4

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

Ingen

Beskrivelse

A potential participant is deemed eligible for trial participation if the following criteria are met:

  1. TAVI as decided by local multidisciplinary heart team
  2. CT-derived annular perimeters fall within the following ranges:

    • 55.5 - 57.5 mm
    • 61.0 - 64.5 mm
    • 70.5 - 74.0 mm
    • 79.5 - 84.0 mm
    • 92.0 - 96.0 mm
  3. Written informed consent

Exclusion Criteria:

A potential participant will be excluded from trial participation in case of inability to provide informed consent.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Self-expanding Evolut transcatheter heart valve series
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis. This is a routine medical procedure, not a study intervention.
Andre navne:
  • TAVI
  • TAVR
  • Transkateter aortaklapimplantation
  • Transkateter aortaklap udskiftning
Eksperimentel: Balloon-expandable Myval transcatheter heart valve series
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis. This is a routine medical procedure, not a study intervention.
Andre navne:
  • TAVI
  • TAVR
  • Transkateter aortaklapimplantation
  • Transkateter aortaklap udskiftning

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
A composite safety end point as per VARC-3 guidelines
Tidsramme: 30 days
A composite safety end point as per VARC-3 guidelines that consists of all-cause mortality, all stroke, type 2 to 4 bleeding, major vascular access-related or cardiac structural complications, acute kidney injury stage 3 to 4, moderate or severe aortic regurgitation, new permanent pacemaker implantation due to conduction abnormalities, surgery or intervention related to the device at 30 days after TAVI as defined in accordance with criteria stated by the third Valve Academic Research Consortium (VARC-3).
30 days

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
A composite safety endpoint as per VARC-3 guidelines
Tidsramme: Annually, up to 5 years
All clinical end points will be assessed after TAVI
Annually, up to 5 years
Hemodynamic performance
Tidsramme: At 30 days (+2 months) and at 1, 3 and 5 years
Hemodynamic performance will be assessed by transthoracic echocardiography
At 30 days (+2 months) and at 1, 3 and 5 years
Patient-reported outcomes, using the Kansas City Cardiomyopathy Questionnaire (KCCQ)-12
Tidsramme: Yearly, up to 5 years
Yearly, up to 5 years

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Ronak Delewi, Prof. Dr., Amsterdam University Medical Center

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. august 2026

Primær færdiggørelse (Anslået)

1. august 2033

Studieafslutning (Anslået)

1. august 2033

Datoer for studieregistrering

Først indsendt

1. juli 2026

Først indsendt, der opfyldte QC-kriterier

1. juli 2026

Først opslået (Faktiske)

8. juli 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

8. juli 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

1. juli 2026

Sidst verificeret

1. juli 2026

Mere information

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .