- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07689279
Selection of Transcatheter Heart vaLve With Intermediate Sizing in Patients With Severe Aortic Stenosis Treated With Transcatheter Aortic Valve Replacement (SELECT TAVR)
Selection of transcathEter Heart vaLve With intermEdiate Sizing in Patients With Severe aortiC Stenosis Treated With Transcatheter Aortic Valve Replacement
Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.
The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.
Objectives:
The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.
Study design:
The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.
Study population:
The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges
Przegląd badań
Status
Interwencja / Leczenie
Typ studiów
Zapisy (Szacowany)
Faza
- Faza 4
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Elsbeth C. Noppers, MD
- Numer telefonu: +31 (0) 20 566 2893
- E-mail: e.c.noppers@amsterdamumc.nl
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
A potential participant is deemed eligible for trial participation if the following criteria are met:
- TAVI as decided by local multidisciplinary heart team
CT-derived annular perimeters fall within the following ranges:
- 55.5 - 57.5 mm
- 61.0 - 64.5 mm
- 70.5 - 74.0 mm
- 79.5 - 84.0 mm
- 92.0 - 96.0 mm
- Written informed consent
Exclusion Criteria:
A potential participant will be excluded from trial participation in case of inability to provide informed consent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Self-expanding Evolut transcatheter heart valve series
|
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis.
This is a routine medical procedure, not a study intervention.
Inne nazwy:
|
|
Eksperymentalny: Balloon-expandable Myval transcatheter heart valve series
|
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis.
This is a routine medical procedure, not a study intervention.
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
A composite safety end point as per VARC-3 guidelines
Ramy czasowe: 30 days
|
A composite safety end point as per VARC-3 guidelines that consists of all-cause mortality, all stroke, type 2 to 4 bleeding, major vascular access-related or cardiac structural complications, acute kidney injury stage 3 to 4, moderate or severe aortic regurgitation, new permanent pacemaker implantation due to conduction abnormalities, surgery or intervention related to the device at 30 days after TAVI as defined in accordance with criteria stated by the third Valve Academic Research Consortium (VARC-3).
|
30 days
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
A composite safety endpoint as per VARC-3 guidelines
Ramy czasowe: Annually, up to 5 years
|
All clinical end points will be assessed after TAVI
|
Annually, up to 5 years
|
|
Hemodynamic performance
Ramy czasowe: At 30 days (+2 months) and at 1, 3 and 5 years
|
Hemodynamic performance will be assessed by transthoracic echocardiography
|
At 30 days (+2 months) and at 1, 3 and 5 years
|
|
Patient-reported outcomes, using the Kansas City Cardiomyopathy Questionnaire (KCCQ)-12
Ramy czasowe: Yearly, up to 5 years
|
Yearly, up to 5 years
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Ronak Delewi, Prof. Dr., Amsterdam University Medical Center
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
- Choroba zastawki aortalnej
- Choroby układu krążenia
- Choroby serca
- Choroby zastawek serca
- Niedrożność odpływu komorowego
- Zwężenie zastawki aortalnej
- Procedury chirurgiczne, operacyjny
- Procedury chirurgiczne sercowo -naczyniowe
- Procedury chirurgiczne serca
- Procedury chirurgiczne klatki piersiowej
- Implantacja protezy
- Implantacja proteza zastawki serca
- Przezcatecznik Wymiana zastawki aortalnej
Inne numery identyfikacyjne badania
- NL-011489
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .