Selection of Transcatheter Heart vaLve With Intermediate Sizing in Patients With Severe Aortic Stenosis Treated With Transcatheter Aortic Valve Replacement (SELECT TAVR)
Selection of transcathEter Heart vaLve With intermEdiate Sizing in Patients With Severe aortiC Stenosis Treated With Transcatheter Aortic Valve Replacement
Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.
The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.
Objectives:
The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.
Study design:
The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.
Study population:
The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Tipo de estudo
Inscrição (Estimado)
Estágio
- Fase 4
Contactos e Locais
Contato de estudo
- Nome: Elsbeth C. Noppers, MD
- Número de telefone: +31 (0) 20 566 2893
- E-mail: e.c.noppers@amsterdamumc.nl
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
A potential participant is deemed eligible for trial participation if the following criteria are met:
- TAVI as decided by local multidisciplinary heart team
CT-derived annular perimeters fall within the following ranges:
- 55.5 - 57.5 mm
- 61.0 - 64.5 mm
- 70.5 - 74.0 mm
- 79.5 - 84.0 mm
- 92.0 - 96.0 mm
- Written informed consent
Exclusion Criteria:
A potential participant will be excluded from trial participation in case of inability to provide informed consent.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Self-expanding Evolut transcatheter heart valve series
|
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis.
This is a routine medical procedure, not a study intervention.
Outros nomes:
|
|
Experimental: Balloon-expandable Myval transcatheter heart valve series
|
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis.
This is a routine medical procedure, not a study intervention.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
A composite safety end point as per VARC-3 guidelines
Prazo: 30 days
|
A composite safety end point as per VARC-3 guidelines that consists of all-cause mortality, all stroke, type 2 to 4 bleeding, major vascular access-related or cardiac structural complications, acute kidney injury stage 3 to 4, moderate or severe aortic regurgitation, new permanent pacemaker implantation due to conduction abnormalities, surgery or intervention related to the device at 30 days after TAVI as defined in accordance with criteria stated by the third Valve Academic Research Consortium (VARC-3).
|
30 days
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
A composite safety endpoint as per VARC-3 guidelines
Prazo: Annually, up to 5 years
|
All clinical end points will be assessed after TAVI
|
Annually, up to 5 years
|
|
Hemodynamic performance
Prazo: At 30 days (+2 months) and at 1, 3 and 5 years
|
Hemodynamic performance will be assessed by transthoracic echocardiography
|
At 30 days (+2 months) and at 1, 3 and 5 years
|
|
Patient-reported outcomes, using the Kansas City Cardiomyopathy Questionnaire (KCCQ)-12
Prazo: Yearly, up to 5 years
|
Yearly, up to 5 years
|
Colaboradores e Investigadores
Investigadores
- Investigador principal: Ronak Delewi, Prof. Dr., Amsterdam University Medical Center
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
- Doença da Valva Aórtica
- Doenças cardiovasculares
- Doenças cardíacas
- Doenças das válvulas cardíacas
- Obstrução do Fluxo Ventricular
- Estenose da Válvula Aórtica
- Procedimentos cirúrgicos, operatórios
- Procedimentos cirúrgicos cardiovasculares
- Procedimentos cirúrgicos cardíacos
- Procedimentos cirúrgicos torácicos
- Implante de prótese
- Implante de prótese da válvula cardíaca
- Substituição da válvula aórtica transcateter
Outros números de identificação do estudo
- NL-011489
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .