Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Clinical Validation of SMD-AFECG for Predicting New-Onset Atrial Fibrillation Within 2 Hours Using Single-Lead ECG Data

20. Juli 2026 aktualisiert von: HUINNO Co., Ltd

A Retrospective, Single-Center, Single-Arm, Superiority Confirmatory Study to Evaluate the Clinical Validity of SMD-AFECG, Artificial Intelligence Software to Predict the Risk of Atrial Fibrillation, Including First Episode Within 2 Hours, Using Single-Lead-Based Electrocardiogram Analysis

The purpose of this retrospective study is to evaluate the clinical performance of SMD-AFECG, an artificial intelligence-based medical device software that predicts the risk of atrial fibrillation occurring within 2 hours using single-lead electrocardiogram data. A total of 797 eligible electrocardiogram datasets collected through VitalDB at Seoul National University Hospital will be included. The performance of SMD-AFECG will be evaluated separately for new-onset atrial fibrillation in patients without a previous history of atrial fibrillation (NOAF) and atrial fibrillation episodes in patients with a previous history of atrial fibrillation (RAF). Two physicians blinded to the software results will review the electrocardiogram data and relevant medical records to establish the reference-standard classification. The blinded electrocardiogram datasets will then be analyzed using SMD-AFECG, and the software-generated predictions will be compared with the reference standard to evaluate the area under the receiver operating characteristic curve for NOAF and RAF.

Studienübersicht

Status

Noch keine Rekrutierung

Detaillierte Beschreibung

This clinical study is designed as a retrospective, single-center, single-arm, superiority confirmatory clinical performance study.

Pre-screening Electronic medical records and the VitalDB database at Seoul National University Hospital will be reviewed to identify potentially eligible data. The study will use continuous single-lead electrocardiogram data collected through VitalDB between September 1, 2022, and before September 30, 2025, from patients who were 19 years of age or older at the time of data collection.

Screening and Data Collection A screening number will be assigned sequentially to each potentially eligible case. Eligibility will be determined by reviewing the predefined inclusion and exclusion criteria. For eligible cases, continuous single-lead electrocardiogram data, signal loss, heart rate, the occurrence and timing of atrial fibrillation episodes, the electrocardiogram collection period, demographic information, previous history of atrial fibrillation, and pregnancy status will be collected. Directly identifying personal information will not be collected.

Test Dataset Creation Eligible data will be classified according to the presence or absence of a previous history of atrial fibrillation and the occurrence of an atrial fibrillation episode. The datasets will be categorized as new-onset atrial fibrillation positive or negative and repeated atrial fibrillation positive or negative. A subject number will then be assigned to each eligible dataset.

The planned sample size is 797 cases, including 462 cases for the evaluation of new-onset atrial fibrillation and 335 cases for the evaluation of repeated atrial fibrillation.

Reference Standard Establishment Two physicians with at least 5 years of relevant clinical experience will independently review the electrocardiogram data and relevant medical records. They will assess the suitability of the electrocardiogram data, confirm the presence or absence and timing of atrial fibrillation episodes, and verify the previous history of atrial fibrillation. Any disagreement between the physicians will be resolved according to the procedures specified in the study protocol. The final agreed classification will be used as the reference standard.

Application of the Investigational Device The medical device operator will receive the test electrocardiogram datasets labeled only with screening numbers and will not be provided with the reference-standard results or positive or negative group classifications. The blinded datasets will be analyzed using SMD-AFECG to generate the predicted risk of atrial fibrillation occurring within 2 hours. The software-generated results will be recorded in the electronic data capture system.

Statistical Analysis The software-generated predictions will be compared with the reference-standard classifications. The primary performance measures are the areas under the receiver operating characteristic curves for the prediction of new-onset atrial fibrillation and repeated atrial fibrillation. Two-sided 95% confidence intervals will be calculated using DeLong's method with a Wald-type confidence interval.

The performance criterion for new-onset atrial fibrillation will be met if the lower bound of the 95% confidence interval for the area under the curve is greater than 0.7753. The performance criterion for repeated atrial fibrillation will be met if the corresponding lower bound is greater than 0.8299. The study will be considered successful only if both primary performance criteria are met.

Secondary performance measures include the area under the precision-recall curve, precision, recall, F1 score, sensitivity, specificity, positive predictive value, negative predictive value, confusion-matrix results at different thresholds, and prediction time horizon.

Because this is a retrospective study using previously collected data, there will be no direct participant contact, additional examination, treatment, or change in clinical care.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

797

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

Patients aged 19 years or older whose continuous single-lead electrocardiogram data were collected through VitalDB at Seoul National University Hospital from September 1, 2022, to before September 30, 2025. Eligible datasets will be identified retrospectively from the VitalDB registry and corresponding clinical records. The study population includes patients with and without a previous history of atrial fibrillation and with or without an atrial fibrillation episode during the predefined assessment window. Eligible datasets will be classified into the NOAF-positive, NOAF-negative, RAF-positive, and RAF-negative groups.

Beschreibung

Inclusion Criteria:

  • Existing continuous single-lead electrocardiogram data collected through VitalDB at Seoul National University Hospital from September 1, 2022, to before September 30, 2025
  • Participant aged 19 years or older at the time of electrocardiogram data collection
  • Availability of an electrocardiogram dataset meeting one of the following criteria:

    • No previous history of atrial fibrillation and a first atrial fibrillation episode, with continuous atrial fibrillation-free electrocardiogram data for the 2 hours before onset and electrocardiogram data for 1 hour after onset (NOAF-positive group)
    • No previous history of atrial fibrillation and no atrial fibrillation episode, with continuous atrial fibrillation-free electrocardiogram data for the 2 hours before a selected index time and electrocardiogram data for 1 hour after the index time (NOAF-negative group)
    • Previous history of atrial fibrillation and an atrial fibrillation episode, with continuous atrial fibrillation-free electrocardiogram data for the 2 hours before onset and electrocardiogram data for 1 hour after onset (RAF-positive group)
    • Previous history of atrial fibrillation and no atrial fibrillation episode, with continuous atrial fibrillation-free electrocardiogram data for the 2 hours before a selected index time and electrocardiogram data for 1 hour after the index time (RAF-negative group)
  • If atrial fibrillation occurred within 2 hours after the start of electrocardiogram recording, availability of electrocardiogram data from the start of recording through up to 1 hour after atrial fibrillation onset, with a minimum recorded electrocardiogram duration of 10 minutes

Exclusion Criteria:

  • Electrocardiogram data considered to be of inadequate quality because of noise, poor equipment handling, unclear signals, artifacts, or similar problems
  • Electrocardiogram data with signal loss of 5 percent or greater
  • Electrocardiogram data with a heart rate below 30 beats per minute or above 300 beats per minute
  • Data collected from a participant who was pregnant or breastfeeding at the time of data collection
  • Data previously used for training or validation of the artificial intelligence model
  • Data considered unsuitable for this clinical study by the principal investigator

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
NOAF Positive Group
Single-lead electrocardiogram datasets from patients without a previous history of atrial fibrillation that include the first atrial fibrillation episode. The datasets include an atrial fibrillation-free electrocardiogram period before the onset of atrial fibrillation and electrocardiogram data following its onset. SMD-AFECG will be retrospectively applied to estimate the risk of atrial fibrillation occurring within 2 hours.
NOAF Negative Group
Single-lead electrocardiogram datasets from patients without a previous history of atrial fibrillation and without an atrial fibrillation episode during the predefined assessment period. The datasets include a continuous atrial fibrillation-free electrocardiogram period before a selected index time and electrocardiogram data following the index time. SMD-AFECG will be retrospectively applied to estimate the risk of atrial fibrillation occurring within 2 hours.
RAF Positive Group
Single-lead electrocardiogram datasets from patients with a previous history of atrial fibrillation that include an atrial fibrillation episode. The datasets include an atrial fibrillation-free electrocardiogram period before the onset of atrial fibrillation and electrocardiogram data following its onset. SMD-AFECG will be retrospectively applied to estimate the risk of atrial fibrillation occurring within 2 hours.
RAF Negative Group
Single-lead electrocardiogram datasets from patients with a previous history of atrial fibrillation and without an atrial fibrillation episode during the predefined assessment period. The datasets include a continuous atrial fibrillation-free electrocardiogram period before a selected index time and electrocardiogram data following the index time. SMD-AFECG will be retrospectively applied to estimate the risk of atrial fibrillation occurring within 2 hours.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
AUROC of SMD-AFECG for Predicting New-Onset Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases (up to 2 hours)
The area under the receiver operating characteristic curve (AUROC) will be calculated by comparing the maximum risk score generated by SMD-AFECG with the reference-standard classification of the NOAF-positive and NOAF-negative ECG datasets. A two-sided 95% confidence interval will be estimated using DeLong's method with a Wald-type confidence interval. The performance criterion will be met if the lower bound of the 95% confidence interval is greater than 0.7753.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases (up to 2 hours)
AUROC of SMD-AFECG for Predicting Repeated Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases (up to 2 hours)
The area under the receiver operating characteristic curve (AUROC) will be calculated by comparing the maximum risk score generated by SMD-AFECG with the reference-standard classification of the RAF-positive and RAF-negative ECG datasets. A two-sided 95% confidence interval will be estimated using DeLong's method with a Wald-type confidence interval. The performance criterion will be met if the lower bound of the 95% confidence interval is greater than 0.8299.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases (up to 2 hours)

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
AUPRC of SMD-AFECG for Predicting New-Onset Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
The area under the precision-recall curve (AUPRC) will be calculated from the relationship between precision and recall using the reference-standard NOAF-positive and NOAF-negative ECG datasets. AUPRC ranges from 0 to 1, with higher values indicating better identification of positive cases.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
AUPRC of SMD-AFECG for Predicting Repeated Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
The area under the precision-recall curve (AUPRC) will be calculated from the relationship between precision and recall using the reference-standard RAF-positive and RAF-negative ECG datasets. AUPRC ranges from 0 to 1, with higher values indicating better identification of positive cases.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Sensitivity of SMD-AFECG for Predicting New-Onset Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, sensitivity, also referred to as recall, will be calculated as the proportion of reference-standard NOAF-positive ECG datasets classified as positive by SMD-AFECG.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Sensitivity of SMD-AFECG for Predicting Repeated Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, sensitivity, also referred to as recall, will be calculated as the proportion of reference-standard RAF-positive ECG datasets classified as positive by SMD-AFECG.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Specificity of SMD-AFECG for Predicting New-Onset Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, specificity will be calculated as the proportion of reference-standard NOAF-negative ECG datasets classified as negative by SMD-AFECG.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Specificity of SMD-AFECG for Predicting Repeated Atrial Fibrillation Within 2 Hours
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, specificity will be calculated as the proportion of reference-standard RAF-negative ECG datasets classified as negative by SMD-AFECG.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Positive Predictive Value of SMD-AFECG for New-Onset Atrial Fibrillation
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, positive predictive value, also referred to as precision, will be calculated as the proportion of ECG datasets classified as positive by SMD-AFECG that are NOAF-positive according to the reference standard.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Positive Predictive Value of SMD-AFECG for Repeated Atrial Fibrillation
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, positive predictive value, also referred to as precision, will be calculated as the proportion of ECG datasets classified as positive by SMD-AFECG that are RAF-positive according to the reference standard.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Negative Predictive Value of SMD-AFECG for New-Onset Atrial Fibrillation
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, negative predictive value will be calculated as the proportion of ECG datasets classified as negative by SMD-AFECG that are NOAF-negative according to the reference standard.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific Negative Predictive Value of SMD-AFECG for Repeated Atrial Fibrillation
Zeitfenster: At each evaluated threshold, negative predictive value will be calculated as the proportion of ECG datasets classified as negative by SMD-AFECG that are RAF-negative according to the reference standard.
At each evaluated threshold, negative predictive value will be calculated as the proportion of ECG datasets classified as negative by SMD-AFECG that are RAF-negative according to the reference standard.
At each evaluated threshold, negative predictive value will be calculated as the proportion of ECG datasets classified as negative by SMD-AFECG that are RAF-negative according to the reference standard.
Threshold-Specific F1 Score of SMD-AFECG for Predicting New-Onset Atrial Fibrillation
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, the F1 score will be calculated as the harmonic mean of precision and recall for the classification of NOAF-positive and NOAF-negative ECG datasets. Values range from 0 to 1, with higher values indicating better performance.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Threshold-Specific F1 Score of SMD-AFECG for Predicting Repeated Atrial Fibrillation
Zeitfenster: During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
At each evaluated threshold, the F1 score will be calculated as the harmonic mean of precision and recall for the classification of RAF-positive and RAF-negative ECG datasets. Values range from 0 to 1, with higher values indicating better performance.
During the AF-free ECG window immediately preceding AF onset for positive cases or the selected index time for negative cases, up to 2 hours
Prediction Time Horizon of SMD-AFECG for New-Onset Atrial Fibrillation
Zeitfenster: Within the 2-hour period before the onset of the first atrial fibrillation episode
The prediction time horizon will be calculated as the time interval, in minutes, between the SMD-AFECG prediction or alarm and the onset of the reference-standard first atrial fibrillation episode among NOAF-positive ECG datasets.
Within the 2-hour period before the onset of the first atrial fibrillation episode
Prediction Time Horizon of SMD-AFECG for Repeated Atrial Fibrillation
Zeitfenster: Within the 2-hour period before the onset of the atrial fibrillation episode
The prediction time horizon will be calculated as the time interval, in minutes, between the SMD-AFECG prediction or alarm and the onset of the reference-standard atrial fibrillation episode among RAF-positive ECG datasets.
Within the 2-hour period before the onset of the atrial fibrillation episode

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Oktober 2026

Primärer Abschluss (Geschätzt)

30. November 2026

Studienabschluss (Geschätzt)

31. Dezember 2026

Studienanmeldedaten

Zuerst eingereicht

20. Juli 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

20. Juli 2026

Zuerst gepostet (Tatsächlich)

23. Juli 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

23. Juli 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

20. Juli 2026

Zuletzt verifiziert

1. Juli 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Beschreibung des IPD-Plans

Individual participant data collected in this study are not planned to be shared with external researchers. Any future sharing would require separate sponsor approval and compliance with applicable privacy, ethical, and institutional requirements.

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren