Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Real-World Validation of A Minimally Disruptive Ambulatory Blood Pressure Monitoring (ABPM) Huawei Smartwatch in Malaysia (Huawei-SunU02)

28. Oktober 2026 aktualisiert von: YookChin Chia, Sunway University

Background:

Ambulatory Blood Pressure Monitoring (ABPM) is the gold standard for diagnosing high blood pressure (hypertension) because it tracks blood pressure continuously across day and night. However, standard ABPM requires a cuff that inflates every 15 to 30 minutes during the day and every 30 to 60 minutes at night. These frequent inflations often cause discomfort, interrupt sleep, and cause patients to abandon testing.

Purpose:

This study aims to evaluate whether a new cuff-based Huawei smartwatch can provide a less-disturbing ABPM experience. Researchers will test whether a reduced-frequency measurement schedule (e.g., 7 readings: 4 awake, 3 asleep) can provide the same diagnostic accuracy as a conventional, full 24-hour ABPM protocol (typically 48 readings) while improving patient comfort.

Study Design & Procedures:

Study Population:

Approximately 500 adult participants will be recruited over a 24-month study period, with a targeted subgroup of 50 participants selected for clinical validation. The subgroup will represent normotensive, pre-hypertensive, and hypertensive individuals across diverse age groups and ethnicities.

Monitoring & Comparison: Participants in the validation group will undergo standard 24-hour ABPM at an accredited clinical facility alongside monitoring with the Huawei smartwatch. Data from the smartwatch will be used to compare a reduced-frequency reading schedule against full 24-hour ABPM recordings.

User Feedback: Participants will complete questionnaires assessing comfort, sleep quality, ease of use, and overall preference between the smartwatch and standard ABPM cuffs.

Goal:

The main goal is to determine if a reduced-frequency wearable monitoring protocol can maintain clinical diagnostic accuracy for blood pressure and sleep-dipping patterns while significantly reducing patient burden and sleep disruption.

Studienübersicht

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

500

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Selangor
      • Subang Jaya, Selangor, Malaysia, 47500
        • Faculty of Medical and Life Sciences, Sunway University

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

The study population comprises adult community-dwelling individuals residing in Malaysia recruited via the Huawei Research Platform. From this general screening pool (target N = 500), a targeted clinical validation subgroup (n = 50) will be prospectively selected to undergo dual ABPM and smartwatch evaluation.

To ensure clinical applicability and statistical validity in alignment with ISO 81060-2 and AAMI validation standards, the validation subgroup will be stratified into three distinct cohorts:

  • Normotensive Cohort (n = 10): Participants with blood pressure < 135/85 mmHg.
  • Undiagnosed Elevated Blood Pressure Cohort (n = 20): Participants with untreated blood pressure > 135/85 mmHg.
  • Documented Hypertensive Cohort (n = 20): Participants with documented or self-reported history of history of hypertension.

Selection across all cohorts will maintain balanced demographic representation across age groups, biological sex, and major Malaysian ethnic populations (Malay, Chinese, Indian)

Beschreibung

Inclusion Criteria:

  • Possesses the specific Huawei wearable required for the study
  • Aged ≥18 years
  • Malaysian citizen/permanent resident
  • Understands English, Malay, or Chinese
  • Able to download the required application on a compatible smartphone
  • Willing to wear devices continuously
  • Able to provide informed consent

Exclusion Criteria:

  • Current pregnancy
  • Presence of implantable cardiac devices (e.g., permanent pacemakers, •implantable cardioverter-defibrillators [ICDs])
  • Uncontrolled cardiac arrhythmias (e.g., active atrial fibrillation, frequent premature ventricular contractions [PVCs])
  • Movement disorders or active tremors that interfere with blood pressure measurement or signal acquisition (e.g., severe Parkinson's disease, essential tremor)
  • Acute medical conditions (e.g., acute coronary syndromes, stroke/TIA within 3 months, acute decompensated heart failure, severe active infections, or hypertensive emergencies)
  • Resting blood pressure >=180/110 mmHg

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Beobachtungsmodelle: ECOLOGIC_OR_COMMUNITY
  • Zeitperspektiven: CROSS_SECTIONAL

Kohorten und Interventionen

Gruppe / Kohorte
Normotensive Cohort

Adult participants with normal blood pressure (defined as blood pressure < 135/85 mmHg; n = 10) who undergo simultaneous standard 24-hour ABPM and Huawei smartwatch monitoring.

Undiagnosed Elevated Blood Pressure Cohort

Adult participants with undiagnosed elevated blood pressure (defined as blood pressure > 135/85 mmHg; n = 20) who undergo simultaneous standard 24-hour ABPM and Huawei smartwatch monitoring.

Documented Hypertensive Cohort

Adult participants with documented or self-reported hypertension (n = 20) who undergo simultaneous standard 24-hour ABPM and Huawei smartwatch monitoring.

Screening Population

General adult participants recruited across Malaysia who enroll via the Huawei Research Platform app to provide continuous wearable ambulatory blood pressure and physiological data and complete baseline health assessments over the study period.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Mean Difference in Blood Pressure Measured by Reduced-Frequency Smartwatch Schedule Versus Standard 24-Hour Ambulatory Blood Pressure Monitor (ABPM)
Zeitfenster: Month 13 through Month 18 (during clinical ABPM validation testing).

Measure Description: Mean blood pressure difference (bias) for 24-hour, daytime, and night-time periods calculated by subtracting reference 24-hour ABPM values (SpaceLabs/Mobil-O-Graph cuff monitor) from reduced-frequency Huawei smartwatch ABPM values (7-measurement schedule).

Unit of Measure: mmHg

Month 13 through Month 18 (during clinical ABPM validation testing).
Mean Absolute Error (MAE) of Blood Pressure Readings Between Reduced-Frequency Smartwatch Schedule and Standard 24-Hour ABPM
Zeitfenster: Month 13 through Month 18.

Measure Description: The average absolute difference between blood pressure readings obtained from the reduced-frequency Huawei smartwatch schedule and the standard 24-hour cuff-based ABPM monitor.

Unit of Measure: mmHg

Month 13 through Month 18.
Root Mean Square Error (RMSE) of Blood Pressure Readings Between Reduced-Frequency Smartwatch Schedule and Standard 24-Hour ABPM
Zeitfenster: Month 13 through Month 18

Measure Description: The root mean square error evaluating agreement between blood pressure values recorded by the reduced-frequency Huawei smartwatch schedule and the standard 24-hour cuff-based ABPM monitor.

Unit of Measure: mmHg

Month 13 through Month 18
Intraclass Correlation Coefficient (ICC) of Blood Pressure Measurements Between Reduced-Frequency Smartwatch Schedule and Standard 24-Hour ABPM
Zeitfenster: Month 13 through Month 18

Measure Description: Agreement reliability calculated using absolute-agreement two-way random-effects ICC comparing reduced-frequency Huawei smartwatch blood pressure estimates against full 24-hour ABPM readings.

Unit of Measure: Intraclass Correlation Coefficient (score ranging from -1.0 to +1.0)

Month 13 through Month 18

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Limits of Agreement (Bland-Altman) for Blood Pressure Readings Between Huawei Smartwatch and Conventional Cuff ABPM
Zeitfenster: Month 13 through Month 18

Measure Description: Upper and lower 95% limits of agreement (mean difference +/- 1.96 x standard deviation) calculated via Bland-Altman analysis comparing simultaneous Huawei smartwatch and conventional cuff-based ABPM measurements.

Unit of Measure: mmHg

Month 13 through Month 18
Participant Comfort Score Evaluated via Post-Monitoring User Experience Survey
Zeitfenster: Immediately following completion of 24-hour monitoring (Month 13 through Month 18)

Measure Description: Mean total score for participant-reported physical comfort derived from a standardized 5-point Likert scale questionnaire administered immediately after 24-hour monitoring.

Unit of Measure: Score on a scale of 1 to 5 (where 1 = Extreme Discomfort and 5 = Complete Comfort)

Immediately following completion of 24-hour monitoring (Month 13 through Month 18)
Number of Participants Indicating Preference for Smartwatch Monitoring Over Conventional Cuff ABPM
Zeitfenster: Immediately following completion of 24-hour monitoring (Month 13 through Month 18)

Measure Description: Count of participants who express a preference for smartwatch-based monitoring over traditional arm-cuff ABPM on the post-monitoring user experience survey.

Unit of Measure: Participant count

Immediately following completion of 24-hour monitoring (Month 13 through Month 18)

Andere Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Cohen's Kappa Coefficient for Nocturnal Dipping Pattern Classification Concordance
Zeitfenster: Month 16 through Month 20.

Measure Description: Inter-rater agreement (Cohen's Kappa) for categorizing participants into nocturnal dipping status categories (dipper vs. non-dipper) comparing reduced-frequency smartwatch schedules against standard full-day ABPM.

Unit of Measure: Kappa Statistic (score ranging from -1.0 to +1.0)

Month 16 through Month 20.
Minimum Number of Measurements Required to Maintain Diagnostic Accurac
Zeitfenster: Month 16 through Month 20.

Measure Description: The minimum threshold count of active blood pressure inflations required per 24-hour period to maintain an ICC >= 0.80 relative to standard 24-hour ABPM.

Unit of Measure: Number of blood pressure inflations

Month 16 through Month 20.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Yook Chin Chia, Sunway University
  • Hauptermittler: Yee How Say, BSc PhD, Sunway University

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Allgemeine Veröffentlichungen

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

15. Dezember 2026

Primärer Abschluss (Geschätzt)

30. November 2028

Studienabschluss (Geschätzt)

31. Dezember 2028

Studienanmeldedaten

Zuerst eingereicht

28. Oktober 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

28. Oktober 2026

Zuerst gepostet (Tatsächlich)

3. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

3. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

28. Oktober 2026

Zuletzt verifiziert

1. Oktober 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

JA

Beschreibung des IPD-Plans

De-identified individual participant data (IPD) collected during this study will be shared with qualified external researchers. Specific shared data elements include:

  • Demographics & Baseline Characteristics: De-identified participant age, sex, body mass index, and baseline clinical blood pressure measurements.
  • Wearable Sensor Data: Continuous physiological streams captured via the Huawei Research Platform, including raw photoplethysmography (PPG) signals, heart rate, heart rate variability, physical activity metrics, and sleep tracking parameters.
  • Reference ABPM Data: Matched 24-hour, daytime, and night-time blood pressure and heart rate values, along with derived nocturnal dipping indices, obtained from clinical cuff-based ABPM and reduced-frequency Huawei smartwatch schedules.
  • User Experience Data: De-identified survey scores on device comfort, ease of use, sleep disturbance, and monitoring preference.

IPD-Sharing-Zeitrahmen

Access Start Date: 6 months after the publication of the primary study results in a peer-reviewed journal.

Access End Date: 5 years after initial publication.

IPD-Sharing-Zugriffskriterien

Method of Access: Data will be made available via a secure, managed data repository (or directly from the Principal Investigator upon formal request).

Qualified Requesters: Scientific researchers affiliated with recognized academic, clinical, or research institutions.

Request Requirements: Requesters must submit a methodologically sound research proposal and a clear scientific rationale for secondary analysis.

Data Use Agreement (DUA): Execution of a formal Data Use Agreement (DUA) is required to ensure data protection, mandate non-re-identification, and enforce secure handling.

Compliance: All shared files will be fully de-identified in compliance with the Personal Data Protection Act (PDPA) Malaysia and institutional Ethics Committee guidelines.

Art der unterstützenden IPD-Freigabeinformationen

  • STUDIENPROTOKOLL
  • SAFT
  • ICF

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren