Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Use of 3D/4D Ultrasound in the Evaluation of Fetal Anomalies

31 de mayo de 2015 actualizado por: The University of Hong Kong

Use of 3D/4D Ultrasound in the Evaluation of Fetal Anomalies - The Use of Volumetry by Three Dimensional Ultrasound in the First Trimester

Volumetry measurements can be a potential clinical use as non-invasive tools in prenatal diagnosis and screening and helps to reduce the risk and complications of invasive procedures. 3DUS volumetry gives more precise results than 2DUS volumetry measurements, particularly, of irregularly shaped objects.

Descripción general del estudio

Estado

Terminado

Descripción detallada

Conventionally volume measurements can be made by using multiplanar or VOCALTM (Virtual Organ Computer-aided AnaLysis). Recently, a new technique, XI VOCALTM (eXtended Imaging VOCAL) has been described. Combined with the inversion mode, measurements for the liquid-filled structures can also be made. The potential use in clinical diagnosis and prediction of pathologies of volume measurements particularly in the first trimester are yet to be investigated.

3D ultrasound is found to be superior to 2D parameter in volumetry measurement. However, currently, there are still very few studies done to evaluate the potential use of volumetry measurement in clinical practice, especially of the validity and reproducibility of XI VOCALTM; and the variation of results obtained within different ultrasound machines. Due to the potential use of volumetry measurements in clinical practice, the accuracy in volumetry measurement is very important and the development of new technique need to be fully explored so that its benefits can be fully used for the contribution of clinical practice.

So far no research has been done to evaluate the difference in the results obtained between different ultrasound machines, in particularly for volumetry measurements. This is important because if there is no significant difference in results between difference machines, we can accumulate the results from these machines for a study, which can include a more variety of samples. Furthermore, it will be much easier to compare results of one machine with another for similar studies.

Both Voluson 730 and Accuvix have been used widely in research studies on 3D volumetry but comparison of the results obtained from these two machines have not been done. We do not know whether the results generated from one machine can be extrapolated to the other machine for clinical or research purpose. Thus more research needs to be done in this area.

Thus, this study is carried out to evaluate the potential use of the new modality of XI VOCALTM in the volumetry measurement of regular and irregular shaped objects, comparison of results obtained between different widely used machines, and the potential used of volumetry measurements in the prediction of common and important clinical pathologies such as αº-thalassemia.

Tipo de estudio

De observación

Inscripción (Actual)

195

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Hong Kong
      • Hong Kong, Hong Kong, Porcelana
        • Tsan Yuk Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 45 años (Adulto)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Femenino

Método de muestreo

Muestra de probabilidad

Población de estudio

  1. Use of XI VOCALTM in 3D fetal volumetry measurements,comparison with multiplanar and VOCALTM

    -restropective(2005-2007),30 singleton pregnancies,11-14 weeks' gestation, at risk of homozygous αº-thalassaemia.

  2. Use of XI VOCALTM in 3D placental volumetry measurements,comparison with multiplanar and VOCALTM

    -retrospective(2005-2007), 32 singleton pregnancies,11-14 weeks' gestation at risk of homologous alphaº thalassaemia.

  3. Comparison of 3DUS volumetry measurement between two models of ultrasound machine -prospective(December 2007-June 2008),30 singleton normal pregnancies,11-14 weeks' gestation.
  4. Use of 3DUS in fetal, gestational sac and placenta quotient measurement, fetuses at risk of homozygous αº-thalassemia(Hb Bart's disease) -retrospective(datasets July 2007-Dec 2008),singleton pregnancies,11-14 weeks' gestation,26 affected cases,34 unaffected cases,43 normal control.

Descripción

Inclusion Criteria:

For objective 1 and 2 - Samples are recruited from our prenatal diagnostic clinic at Ysan Yuk Hospital between 11-14 weeks' gestation. They are those who come for routine scan and those who are referred from the general antenatal clinics of the same hospital which pregnancies are at risk of homologous alphaº thalassaemia.

For objective 3 - Recruitment are the same as above except samples are obtained from normal pregnancy.

For objective 4 - Recruitment are the same as above. However, study is divided into intervention group and control group. For the intervention group, data is collected from pregnancies at risk of of homozygous αº-thalassemia while for the control group, data is collected from normal pregnancies.

Exclusion Criteria:

  • If women refuse to participate in the study
  • Patients with other co-existing illnesses

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: Control de caso

Cohortes e Intervenciones

Grupo / Cohorte
Objective 1: XI VOCALTM in 3D fetal volumetry measurement
group 1: multiplanar; group 2: VOCALTM; group 3: XI VOCALTM
Objective 2: XI VOCALTM in 3D placental volumetry measurement
group 1: multiplanar; group 2: VOCALTM; group 3: XI VOCALTM
Objective 3: Comparison between 2 ultrasound machine
  1. intramachine reliability for (i)fetal, (ii)gestational sac and (iii)placenta volumetry measurement for (a)multiplanar and (b)VOCALTM:- group 1:Accuvix; group 2:Voluson 730
  2. intermachine reliability for fetal, gestational sac and placenta volumetry measurement for (a)multiplanar and (b)VOCALTM for Accuvix and Voluson 730
Objective 4:3D volumetry in fetuses at risk of Hb Bart's
Measurement of fetal, gestational sac and placenta volume per CRL quotient using multiplanar technique:- group 1: affected; group 2: unaffected

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Objective 1:The use of XI VOCALTM in 3D volumetry measurements of fetal head and trunk of fetuses from 11 to 14 weeks gestation and known volume phantoms and its comparison with the conventional multiplanar and VOCALTM technique
Periodo de tiempo: 18 months

The objectives of this study are to compare (1) the reproducibility of multiplanar and the VOCALTM technique for 3DUS measurement of fetal volume with the new modality XI VOCALTM, and (2) validity of these three techniques using an in-vitro setting.

The hypothesis of the study are (1) the results obtained from the new modality of XI VOCALTM is interchangeable with multiplanar and VOCALTM with similar number of steps used and (2) validity between XI VOCALTM is comparable to multiplanar and VOCALTM with similar number of steps used.

We hypothesized XI VOCALTM can be used interchangeably with multiplanar and VOCALTM technique if similar number of steps are used in the measurement of regular objects such as fetal head and trunk.

18 months
Objective 2:The use of new modality of XI VOCALTM in 3D volumetry measurements of placenta from 11 to 14 weeks gestation and known volume phantoms and its comparison with the conventional multiplanar and VOCALTM technique
Periodo de tiempo: 18 months

The objectives of this study are to compare (1) the reproducibility of multiplanar and the VOCALTM technique for 3DUS measurement of placenta volume with the new modality XI VOCALTM, and (2) validity of these three techniques using an in-vitro setting.

The hypothesis of the study are (1) the results obtained from the new modality of XI VOCALTM is interchangeable with multiplanar and VOCALTM with similar number of steps used and (2) validity between XI VOCALTM is comparable to multiplanar and VOCALTM with similar number of steps used.

We hypothesized that XI VOCALTM can be used interchangeably with the other two techniques for the volumetry measurement of irregular objects such as placenta if similar number of steps is used.

18 months
Objective 3:The use of 3DUS in the volumetry of first trimester pregnancy and in vitro study: comparison between two models of ultrasound machine
Periodo de tiempo: 18 months

The objective of the present study are to compare (1) the reproducibility of these two machines for fetal, gestational sac and placenta 3D volumetry using multiplanar (1-mm interval) and Virtual Organ Computer-Aided Analysis (VOCAL)TM (30º) technique and (2) validity of these two machines using an in-vitro setting.

Hypothesis of the study: 3D volumetry measurement of fetal, gestational sac and placenta volume of fetuses at 11 to 14 weeks' gestation with Voluson 730 is interchangeable with the measurement using Accuvix ultrasound machine.

We hypothesized that the Accuvix machine could be used interchangeably with Voluson 730 for both multiplanar and VOCALTM for fetal, gestational sac and placenta volumetry measurement.

18 months
Objective 4:The use of 3DUS in the measurement of fetal, gestational sac and placenta quotient of fetuses at risk of homozygous αº-thalassemia (Hb Bart's disease) at 11 to 14 weeks' gestation
Periodo de tiempo: 18 months

This study was carried out to evaluate the use of fetal, gestational sac and placenta volume measured by three-dimensional (3D) ultrasound in predicting fetal homozygous αº-thalassemia (Hb-Bart's disease).

Hypothesis of the study: Measurement of 3D volume of the fetal, gestational sac and placenta quotient can be used as a useful tool as 2D parameter for the prediction of fetuses of homozygous alpha0-thalassaemia (Hb Bart's disease) at 11 to 14 weeks' gestation.

We hypothesized that 3D volumetry measurement of the fetal, gestational sac and placenta quotient can serve as a useful tool as 2D parameter for the prediction of homozygous alpha0-thalassaemia (Hb Bart's disease) fetuses at 11 to 14 weeks' gestation.

18 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Kah Bik Cheong, BSc(Hons), MMedSc, MBBS, The University of Hong Kong
  • Director de estudio: Kwok Yin Leung, MBBS, FHKAM, The University of Hong Kong

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Enlaces Útiles

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de marzo de 2008

Finalización primaria (Actual)

1 de junio de 2009

Finalización del estudio (Actual)

1 de agosto de 2009

Fechas de registro del estudio

Enviado por primera vez

21 de enero de 2009

Primero enviado que cumplió con los criterios de control de calidad

21 de enero de 2009

Publicado por primera vez (Estimar)

22 de enero de 2009

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

2 de junio de 2015

Última actualización enviada que cumplió con los criterios de control de calidad

31 de mayo de 2015

Última verificación

1 de mayo de 2015

Más información

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir