Echogenic Versus Stimulating Needle and Catheter for Sciatic Blocks (Echostim1)

19 de abril de 2013 actualizado por: Sugantha Ganapathy, Lawson Health Research Institute

Comparison of Visibility of Echogenic and Standard Non-echogenic Block Needles During Ultrasound Guided Sciatic Blocks. A Randomized Prospective Study

Patients scheduled for total knee replacements and suitable for sciatic nerve block will be randomized to one of 2 groups.

Group 1 will have the nerve block performed using a standard Pajunk block needle under ultrasound guidance and with electrical nerve stimulation (ENS), and have catheter placement also guided by electrical nerve stimulation. Group 2 will have the block performed using a Sonoplex echogenic block needle and have an echogenic catheter sited, all under ultrasound (US) guidance. Group 2 will have needle location aided by ENS, but ENS will not be used for catheter location.

An observer blinded to the needle type will assess the quality of needle visualisation on a recording of the US image taken during the procedure, along with adequacy of spread of local anesthetic. The primary outcome will be needle visibility, and secondary outcomes will be block success rate, block performance time, complication rate, number of needle passes per block, and adequacy of spread of local anesthetic.

Descripción general del estudio

Descripción detallada

A total of 70 patients with ASA physical status 1 to 4, scheduled for elective total knee arthroplasty and deemed suitable to receive a sciatic nerve block will be included in the study. They will be randomised to one of two groups prior to the block procedure using a closed envelope system.

Recruitment will take place in the preoperative clinic. All blocks will be performed in the block room using standard monitoring, sterile precautions and titrated intravenous sedation.

Prior to the sciatic nerve block a continuous femoral nerve block will be performed according to standard procedure. Once this is complete the patient will be positioned for the sciatic nerve block.

A preprocedural scan will be done as per standard practice and skin will be infiltrated with 1% lidocaine.

The anaesthetist performing the block will be aware of the study group allocation due to the requirement for physically handling the block needles, and will proceed to position the needle into the required location site to facilitate catheter insertion, with the aid of electrical nerve stimulation via the needle. This will be recorded using the ultrasound machines cineloop facility.

If after 6 passes the operator is unable either to contact the nerve according to the ultrasound image or elicit a twitch response, the procedure will be abandoned and this will be considered a failed block. In this case analgesia will be covered with periarticular infiltration and opioids.

During needle positioning, the observer will record the number of needle redirections required to optimally locate the needle, each redirection being defined as every movement which follows a withdrawal of more than 2cm. The observer will also record the number of skin punctures required and any arterial or venous punctures.

Group E will have the block performed using the echogenic needle, and the echogenic catheter will be placed using ultrasound guidance.

The catheter will be inserted through the needle by a second anesthetist. This process will be continuously recording using the cineloop feature of the ultrasound machine. Once the catheter is deemed to be in an appropriate position, local anaesthetic will be injected by the second anaesthetist while observing the disposition of the local anaesthetic perineurally in short axis. This will be confirmed with a long axis view of the nerve (also recorded).

Group S will have the block performed with a standard needle and catheter, guided by electrical nerve stimulation.

Acceptable muscle twitch response will be plantar- or dorsiflexion, inversion or eversion with an initial nerve current strength of 0.5mA at a frequency of 2Hz. If a satisfactory motor response cannot be elicited, current will be increased in stages to 1.5mA. If a response still cannot be elicited this will be recorded but the catheter will still be used if its position is deemed satisfactory using colour Doppler - a medley of colour adjacent to the nerve with the injection of agitated dextrose 5%. Once the catheter is deemed to be in an appropriate position, local anaesthetic will be injected by the second anaesthetist while observing the disposition of the local anaesthetic perineurally in short axis. This will be confirmed with a long axis view of the nerve (also recorded).

Once the catheter has been sited using the above techniques, a bolus of agitated 5% dextrose will be injected through the catheter and Doppler ultrasound will be used to locate where in the tissues the injected fluid is being deposited. This will also be recorded and subsequently assessed.

An assistant present during the block will time two aspects of the procedure:

  1. Time from first skin contact with needle to first muscle response to nerve stimulation. This will be done only on the day of surgery during the block procedure until the desired muscle twitch is elicited.
  2. Time from first skin contact to completion of catheter insertion (Block time).This is done during the block procedure only on the day of surgery as noted above

Once catheter position has been assessed a total of 20 millilitres of 2% mepivacaine will be injected via the catheter in both groups. Over the subsequent 30 minutes a second blinded observer will take observations every 5 minutes to assess the degree of motor and sensory block.

The video recording of the block procedure will be sent along with the data collection form to two of the co-investigators, who will independently assess the following:

  1. At the time of nerve contact by the needle, assign a rating for visibility of the needle shaft and tip according to the following scale:

    1. not visualised or poorly visualised - needle tip/shaft being isoechoic or only slightly more echogenic than background parenchyma.
    2. tip or shaft visualised with some difficulty - tip/shaft readily identified as being more echogenic than the background parenchyma but not seen in their entirety
    3. excellent visibility shaft and tip strongly echogenic relative to tissue and visualised in their entirety.
  2. Assign the same rating after completion of injection
  3. Judge whether circumferential and longitudinal spread of local anaesthetic is either adequate or inadequate.

Following the operation a standard infusion of 0.1% ropivacaine at 4cc/hr will be commenced via the sciatic catheter. Post operative care will be as per the standard practice at this institution.

One week post operatively the patient will be telephoned at home to check for persisting neurological symptoms.

Tipo de estudio

Intervencionista

Inscripción (Actual)

70

Fase

  • Fase 3

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Ontario
      • London, Ontario, Canadá, N6A 5A5
        • London Health Sciences Centre University Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 80 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Patients age 18-80 years listed for total knee arthroplasty.
  • ASA I-IV.
  • Able to give informed consent
  • Able to cooperate with study protocol.

Exclusion Criteria:

  • Standard contraindication to regional anaesthesia/analgesia: local infection, coagulopathy, local anaesthetic allergy, patient refusal, diabetes mellitus, peripheral neuropathy, pre-existing nerve injury)
  • Inability to consent
  • Patient refusal
  • Pregnant patients

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Echogenic needle and catheter
The echogenic needle will be positioned using ultrasonography and neurostimulation with an end point of plantar or dorsiflexion with 0.6mA of current strength. The catheter will be inserted using ultrasonography alone. 20 Ml of 2% mepivacaine will be inserted using the catheter. The distribution of drug will be evaluated using short axis and long axis views. Sensory motor block evaluation every 5 minutes for 30 minutes. Duration of block procedure, number of passes and success will be evaluated
Visibility of needle shaft and tip with engraved markers. Ultrasonographic Visibility of catheter tip
Otros nombres:
  • Pajunk Stimulong plexus catheter set
  • Pajunk sonolong sonoset
Comparador activo: Neurostimulation
The non echogenic needle will be positioned using ultrasonography and neurostimulation with plantar or dorsiflexion as the end point with 0.6mA current.The catheter will be positioned using neurostimulation with plantar or dorsiflexion with 0.6-1.5mA current.
The non echogenic needle will be positioned using ultrasonography and neurostimulation and the catheter will be positioned using neurostimulation with plantar or dorsiflexion with 0.6-1.5mA current. 20mL of 2% mepivacaine will be injected via the catheter. Sensory motor block will be evaluated every 5 minutes for 30 mins
Otros nombres:
  • Pajunk Stimulaong Plexus catheter set

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Visibility of needle tip and catheter tip
Periodo de tiempo: Day 1
Needle tip visibility graded by blinded observers Catheter tip visibility graded by blinded observers
Day 1

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
number of needle passes
Periodo de tiempo: Day 1
The number of times the needle is withdrawn more than 2 cm and resited
Day 1
success rate of block
Periodo de tiempo: Day 1
Motor and sensory block will be evaluated on standard grading system every 5 minutes for 30 minutes post injection
Day 1
Block procedure time
Periodo de tiempo: Day 1
Time from needle insertion to the end of catheter insertion
Day 1
Immediate complications
Periodo de tiempo: Day 1
Vascular punctures, venous or arterial
Day 1
delayed complications
Periodo de tiempo: One week after surgery/block
telephone interview to elicit delayed neurologic symptoms
One week after surgery/block

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Sugantha Ganapathy, Professor, Director, regional and Pain reseaerch

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de enero de 2012

Finalización primaria (Actual)

1 de enero de 2013

Finalización del estudio (Actual)

1 de enero de 2013

Fechas de registro del estudio

Enviado por primera vez

11 de octubre de 2011

Primero enviado que cumplió con los criterios de control de calidad

13 de diciembre de 2011

Publicado por primera vez (Estimar)

15 de diciembre de 2011

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

23 de abril de 2013

Última actualización enviada que cumplió con los criterios de control de calidad

19 de abril de 2013

Última verificación

1 de enero de 2012

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • R-11-495
  • 17757 (REB)

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .