Study on the Treatment of Dental Implants Using the AmbiJet System for Peri-implantitis and Peri-implant Mucositis (AmbiJet-FIH)

23 de julio de 2026 actualizado por: Freiburger Medizintechnik GmbH

Randomized, Controlled, Exploratory Study on the Treatment of Dental Implants Using the AmbiJet System for Peri-implantitis and Peri-implant Mucositis (AmbiJet-FIH)

Inflammation of the tissue surrounding a dental implant (peri-implantitis or peri-implant mucositis) can lead to implant loss in advanced stages. The AmbiJet system utilizes cold atmospheric plasma (CAP), a physical procedure with a strong antibacterial effect. This clinical trial investigates whether the additional application of cold plasma directly on the patient following conventional mechanical cleaning of the implants is safe, well-tolerated, and resolves inflammation more quickly compared to standard treatment.

Descripción general del estudio

Descripción detallada

Background:

Developments in materials, improvements in techniques, and knowledge of the influence of patient characteristics have led to the increasing use of endosseous dental implants. Initially, a bony connection to the implant surface is established, but biofilm deposits on the implant and associated inflammatory reactions of varying severity can develop, namely peri-implant mucositis and peri-implantitis.

Peri-implant mucositis is the early stage of the disease: a reaction of the soft tissue (gums) around the implant. Peri-implantitis is the advanced stage of the disease and refers to inflammation that has a negative effect on integration into the bone.

Studies from university and private clinics with at least 100 implants reported between 2005 and 2014 showed prevalence data of 43% - 46.83% for peri-implant mucositis and 19.83% - 22% for peri-implantitis. Peri-implant mucositis and periimplantitis have bacterial pathogenesis, although the spectrum of microorganisms varies. Peri-implantitis is more serious because it attacks the bony implant support apparatus and can lead to implant loss in half of all cases. Treatment of peri-implant mucositis counteracts the development of peri-implantitis.

Therefore, according to the S3 guideline, three months of follow-up care is indicated.

The cause of inflammatory peri-implant inflammation is the development of a biofilm, which may be mineralized or non-mineralized. Biofilm is the three-dimensional organization of extracellular matrix and microorganisms that make up dental plaque or plaque in the periodontal pocket. Mineralized and non-mineralized biofilm is removed with a curette using non-surgical, mechanical debridement.

However, a recent survey of professionals shows that debridement may be less successful than assumed.

The S3 guideline acknowledges that peri-implant mucositis may not necessarily heal using conventional methods and that peri-implantitis should be treated using alternative methods such as monotherapy with Er:YAG laser or glycine-based air polishing. Adjuvant antimicrobial photodynamic therapy can be used in the non-surgical treatment of peri-implantitis (S3 guideline, AWMF registration number: 083-023). There is a lack of evidence for a protocol that could counteract the development of secondary peri-implantitis. The AmbiJet treatment principle is based on the local application of cold atmospheric pressure plasma, which generates electrical pulses and reactive oxygen species with antibacterial effects locally and has a positive effect on implant-integrative cell processes. In this RCT, this innovative dental medical device will be used in the treatment of peri-implant mucositis and peri-implantitis to determine the success and safety of its use. The study pursues the hypothesis that the use of plasma will lead to a greater proportion of regression of peri-implant mucositis and periimplantitis after six months.

Short description of the investigational device and its intended use:

The device is the AmbiJet system, which consists of a base unit with an inserted gas cartridge and two interchangeable applicators that are used to apply the electrically conductive plasma converted from the gas in a targeted manner for the appropriate indication in connection with dental implants.

The "periSlide" applicator has been developed for the treatment of peri-implant mucositis where access via the periodontal pocket is possible; the "inDrive" applicator is suitable for the treatment of peri-implantitis with direct access to the implant surface (possibly with the superstructure removed and/or surgical open-flap intervention). The applicators are sterile, single-use items that are attached to the handpiece of the base station.

Design of the clinical Trial:

One qualifying dental implant per patient is randomized; if additional dental implants or adjacent teeth are affected, these are also documented. Randomization is performed separately for the individual diagnoses (parallel groups) per patient:

Dental implants with a diagnosis of peri-implantitis/ peri-implant mucositis. Blinding is not possible because the intervention can only be performed using a separate medical device. Each dental implant receives a treatment indicated in accordance with the guideline for periimplantitis, given the diagnosis and inclusion in the study. In addition, the dental implants randomized to the intervention group receive the study treatment with the AmbiJet system.

The study is designed as a pivotal, hypothesis-driven clinical trial. One dental implant per patient is evaluated for local inflammatory changes.

Preliminary data on this project are included in the manufacturer's evaluation documents and demonstrate an effective and safe medical device.

According to the S3 guideline, the diagnosis of peri-implant mucositis includes clinical signs of inflammation, bleeding on probing, and possibly an increase in probing depths relative to the initial findings, and results in an indication for treatment per diagnosed site on the implant.

According to the S3 guideline, the diagnosis of peri-implantitis includes: clinical signs of inflammation, bleeding on probing, possible suppuration, increase in probing depths relative to the initial findings or, if initial findings are not available, > 6 mm, radiological evidence of bone loss relative to the initial findings or, if initial findings are not available, > 3 mm apical to the imaginary rough-smooth border, and provides the indication for treatment per diagnosed site on the implant.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

26

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Loic Ledernez, Phd
  • Número de teléfono: +49 176 96127565
  • Correo electrónico: ledernez@frmed.de

Ubicaciones de estudio

      • Romny, Ucrania, 42001
        • Reclutamiento
        • LLC "Institute of Implantological Research
        • Contacto:
          • Dmytro Kaplun, Phd
          • Número de teléfono: +38(066) 700-59-25
          • Correo electrónico: da8in4eg@gmail.com
        • Investigador principal:
          • Kaplun Kaplun, Phd

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

General criteria:

  • Men or women aged >= 18 and <= 65 years.
  • For women of childbearing age: a form of contraception recognized by conventional medicine during the study.
  • Written consent has been obtained from each patient for the study.

Dental criteria:

  • Current X-ray of the implant region available (<= 6 months prior to first treatment).
  • One to five implants with bone loss from the start of the part of the implant intended for osseointegration (X-ray findings).
  • Bleeding and/or suppuration after or without probing at the implant in question (peri-implant mucositis/peri-implantitis).
  • Clinical signs of inflammation (swelling, redness, soft tissue) on the implant in question (peri-implant mucositis/peri-implantitis).
  • Average oral hygiene (i.e., brushing teeth at least twice a day).

Exclusion Criteria:

General criteria:

  • Known allergies to materials used in the study (gold, copper, polyimide).
  • Diabetes (type I or type II), vasculitis, osteoporosis, osteomalacia.
  • Smokers (>1 cigarette/week).
  • Use of medications to modulate bone metabolism (e.g., bisphosphonates).
  • Eating disorders such as bulimia or anorexia nervosa.
  • Use of antibiotics within the last 2 months prior to the start of the study.
  • Application of local antibiotics in the oral cavity within the last 2 months prior to the start of the study.
  • Use of antimicrobial mouthwashes within the last month before the start of the study.
  • Anti-inflammatory medication within the last month before the start of the study.
  • Pregnancy or breastfeeding.
  • Alcoholism or drug abuse.
  • Wound healing disorders.
  • Immunosuppression.
  • Condition following insertion of an electrical, electrically active, or electronic implant.

Dental criteria:

  • An implant with bone loss >6 mm from the start of the part of the implant intended for osseointegration (X-ray findings) (peri-implantitis).
  • Pathological changes in the oral mucosa or gingiva, such as oral lichen planus, chronic recurrent aphthae, melanotic macula, precancerous lesions (e.g., leukoplakia), melanomas.
  • Use of medically unacceptable types of treatment, therapies, or substances (off-label use of treatments for peri-implant mucositis or peri-implantitis).

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Standard Mechanical Debridement (S3)
Guideline-compliant standard therapy only, consisting of mechanical, non-surgical debridement of mineralized and non-mineralized biofilm, including rinsing with saline solution and powder jet treatment.
Mechanical, non-surgical debridement of mineralized and non-mineralized biofilm, including rinsing with saline solution and powder jet treatment.
Experimental: AmbiJet Cold Plasma + Standard Debridement
Adjuvant application of cold atmospheric pressure plasma using the AmbiJet system directly onto the affected implant surfaces, performed immediately following standard mechanical debridement according to the S3 guideline.
Mechanical, non-surgical debridement of mineralized and non-mineralized biofilm, including rinsing with saline solution and powder jet treatment.
Adjuvant application of cold atmospheric pressure plasma using the AmbiJet system directly onto the affected implant surfaces, performed immediately following standard mechanical debridement according to the S3 guideline.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Macroscopic tissue reaction measured via Implant Mucosal Index
Periodo de tiempo: Baseline, 1 week, and 4 weeks after initial treatment
Evaluation of local acute tissue reactions and toxicity in the peri-implant mucosa using the Implant Mucosal Index (IMI). The IMI scale ranges from a minimum score of 0 (healthy tissue, no signs of inflammation) to a maximum score of 3 (severe inflammation, pronounced swelling, spontaneous bleeding, or pus discharge). Higher scores indicate a worse outcome (more severe tissue inflammation).
Baseline, 1 week, and 4 weeks after initial treatment
Acute pain and post-interventional morbidity measured via Visual Analog Scale
Periodo de tiempo: Immediately after treatment, 1 week, and 4 weeks after initial treatment
Measurement of the intensity of the patient's pain response during and after treatment using a Visual Analog Scale (VAS). The VAS scale ranges from a minimum score of 0 (no pain) to a maximum score of 10 (worst imaginable pain). Higher scores indicate a worse outcome (greater pain intensity).
Immediately after treatment, 1 week, and 4 weeks after initial treatment

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

14 de febrero de 2026

Finalización primaria (Estimado)

1 de noviembre de 2026

Finalización del estudio (Estimado)

20 de noviembre de 2026

Fechas de registro del estudio

Enviado por primera vez

20 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

20 de julio de 2026

Publicado por primera vez (Actual)

23 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

24 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

23 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 214-54-26

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir