Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Development of a Clinical Decision Support System for Cataract Surgery Planning Using Swept Source Optical Biometry (CAT-OCT)

9 de noviembre de 2026 actualizado por: Clínica de Oftalmología de Cali S.A

This single-center, observational, analytical, ambispective study aims to develop and internally validate a clinical decision support system for cataract surgery planning using swept-source optical coherence tomography (SS-OCT) integrated into the ARGOS optical biometer.

The study will evaluate the ability of preoperative crystalline lens tomographic patterns (Types I-III) to predict surgical complexity and the surgical approach required during cataract extraction. Additionally, it will assess whether SS-OCT-derived information provides incremental predictive value beyond conventional clinical assessment using the Lens Opacities Classification System III (LOCS III).

Clinical, biometric, and surgical data will be analyzed to determine the predictive performance, reproducibility, and technical feasibility of the proposed classification system. The ultimate goal is to establish an objective, noninvasive, and reproducible tool to support personalized surgical planning and preoperative risk stratification in cataract surgery.

Descripción general del estudio

Descripción detallada

Background and Rationale

Cataract remains a leading cause of visual impairment and preventable blindness worldwide. Although advances in surgical techniques and technology have improved cataract surgery outcomes, predicting surgical complexity and selecting the most appropriate surgical approach remain important clinical challenges. Currently, preoperative assessment relies primarily on clinical examination and subjective grading systems, such as the Lens Opacities Classification System III (LOCS III), which may exhibit interobserver variability.

Swept-source optical coherence tomography (SS-OCT), integrated into optical biometers such as ARGOS (Alcon Laboratories, Inc.), provides noninvasive, high-resolution images of the crystalline lens and biometric measurements. These images may reveal morphological characteristics associated with lens opacity, nuclear density, and surgical complexity.

This study proposes the development and internal validation of a clinical decision support system based on the identification of specific crystalline lens tomographic patterns to improve preoperative risk stratification and support cataract surgery planning.

Study Design and Population

This is a single-center, observational, analytical, ambispective study conducted at Clínica de Oftalmología de Cali, Colombia. The study will include patients older than 40 years undergoing crystalline lens extraction who have undergone preoperative optical biometry using the ARGOS device, including SS-OCT imaging of the crystalline lens.

The ambispective design will incorporate retrospectively identified surgical cases and prospectively included patients. Surgical management will follow routine clinical practice, without experimental treatment assignment or modification of the surgical technique by the investigators.

Patients undergoing combined cataract surgery with glaucoma, corneal, or retinal procedures, those with a history of significant ocular trauma affecting anterior segment anatomy, and patients with ocular conditions preventing reliable tomographic image acquisition will be excluded.

A reference group of patients with clear crystalline lenses who underwent ARGOS biometry for indications other than cataract will be used exclusively to characterize the Type I tomographic pattern. These individuals will not be included in the statistical analysis.

Preoperative Assessment and Tomographic Classification

Preoperative evaluation will include demographic characteristics, visual acuity, LOCS III cataract grading, relevant ocular comorbidities, and biometric parameters obtained using ARGOS.

Crystalline lens SS-OCT images will be classified according to three predefined tomographic patterns (Types I, II, and III), based on lens reflectivity, intralenticular signal distribution, and the morphological characteristics of the anterior and posterior lens peaks.

Images will be independently assessed by trained observers blinded to the surgical technique and intraoperative outcomes. Disagreements will be resolved through consensus or third-observer adjudication. Interobserver and intraobserver reproducibility will be evaluated.

Study Outcomes

The primary outcome will be the need for a complex surgical approach during cataract extraction, defined using prespecified objective criteria derived from surgical records and, when available, surgical recordings.

Secondary outcomes will include the specific surgical technique performed, conversion from the initially planned approach, phacoemulsification energy parameters, intraoperative complications, and technical feasibility of SS-OCT image acquisition and interpretation.

Statistical Analysis and Internal Validation

The predictive performance of the proposed tomographic classification will be assessed using sensitivity, specificity, positive and negative predictive values, likelihood ratios, and overall classification accuracy, with 95% confidence intervals.

Multivariable logistic regression will be used to evaluate the association between SS-OCT patterns and surgical complexity. A conventional clinical prediction model based on LOCS III and prespecified clinical variables will be compared with an expanded model incorporating the SS-OCT tomographic classification.

Model discrimination will be evaluated using the area under the receiver operating characteristic curve (AUC-ROC), while calibration will be assessed by comparing predicted and observed outcomes. Internal validation will be performed using bootstrap resampling.

Expected Clinical Relevance

The study seeks to determine whether SS-OCT-derived crystalline lens patterns can provide clinically useful information beyond conventional cataract grading. If validated, this classification could support more objective preoperative assessment, improve identification of surgically complex cases, and facilitate individualized cataract surgery planning using information already available from routine optical biometry.

The proposed system is intended to complement, rather than replace, clinical judgment. Further external validation will be required before its implementation in routine clinical practice.

Tipo de estudio

De observación

Inscripción (Actual)

499

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Valle del Cauca Department
      • Cali, Valle del Cauca Department, Colombia, 760036
        • Clínica de Oftalmología de Cali

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

40 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

For the establishment of the reference group with clear crystalline lenses, patients who underwent optical biometry using the ARGOS device for indications other than cataract, such as myopia monitoring, will be included to characterize the Type I pattern. These patients were not included in the statistical analysis of the study.

The study population will consist of patients older than 40 years with an indication for crystalline lens extraction and preoperative biometry performed using ARGOS, including acquisition of SS-OCT images of the crystalline lens. Patients in whom both the preoperative tomographic pattern and the surgical outcome can be adequately determined will be eligible.

Descripción

Inclusion Criteria:

  • Patients older than 40 years undergoing crystalline lens extraction surgery.
  • Preoperative optical biometry performed using the ARGOS biometer, including swept-source optical coherence tomography (SS-OCT) imaging of the crystalline lens.
  • Availability of sufficient preoperative tomographic information and surgical records to determine both the lenticular tomographic pattern and the surgical outcome.

Exclusion Criteria:

  • Patients undergoing combined cataract surgery with glaucoma, corneal, or retinal procedures.
  • Patients with a history of ocular trauma capable of significantly altering anterior segment anatomy.
  • Patients with ocular conditions that prevent the acquisition of reliable tomographic images using swept-source optical coherence tomography (SS-OCT).

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Modelos observacionales: COHORT
  • Perspectivas temporales: PROSPECTIVE

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Cataract Surgery Patients

Patients older than 40 years undergoing cataract surgery with preoperative swept-source optical coherence tomography (SS-OCT) imaging obtained using the ARGOS biometer. Lenticular tomographic patterns will be classified and evaluated for their ability to predict surgical complexity and the surgical approach required.

Preoperative assessment of crystalline lens tomographic patterns using swept-source optical coherence tomography (SS-OCT) integrated into the ARGOS optical biometer. Images will be classified according to predefined lenticular patterns (Types I-III) to evaluate their predictive value for surgical complexity and surgical approach during cataract extraction.

Otros nombres:
  • ARGOS Biometer
  • ARGOS Swept-Source OCT
  • SS-OCT Optical Biometry

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Predictive Performance of SS-OCT Lenticular Patterns for Surgical Complexity in Cataract Surgery
Periodo de tiempo: 6 months

Assessment of the ability of preoperative crystalline lens tomographic patterns (Types I-III), obtained using swept-source optical coherence tomography (SS-OCT) with the ARGOS biometer, to predict the need for a complex surgical approach during cataract extraction. Surgical complexity will be classified as conventional or complex according to predefined objective criteria derived from operative records. Predictive performance will be evaluated using sensitivity, specificity, positive and negative predictive values, likelihood ratios, and overall classification accuracy, with 95% confidence intervals.

6 months

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Incremental Predictive Value of SS-OCT Compared With LOCS III
Periodo de tiempo: 6 months

Evaluation of the additional predictive value of SS-OCT lenticular patterns beyond conventional clinical assessment using LOCS III. Predictive models will be compared in terms of discrimination, measured by the area under the receiver operating characteristic curve (AUC-ROC), and calibration.

6 months
Distribution of Surgical Techniques Across SS-OCT Lenticular Pattern Categories
Periodo de tiempo: 6 months

To determine the percentage of eyes undergoing each surgical technique within the preoperative lenticular pattern categories (I, II, and III), as classified using swept-source optical coherence tomography (SS-OCT) images obtained with the ARGOS optical biometer.

Surgical techniques will be identified from operative records and categorized as phacoemulsification (divide and conquer, stop and chop, vertical chop, or horizontal chop), extracapsular cataract extraction, or manual small-incision cataract surgery (MSICS).

The frequency distribution of surgical techniques will be compared across SS-OCT lenticular pattern categories using appropriate categorical statistical methods.

6 months
Cumulative Dissipated Energy During Phacoemulsification Across SS-OCT Lenticular Pattern Categories
Periodo de tiempo: 6 months

To quantify cumulative dissipated energy (CDE) during cataract surgery performed using phacoemulsification and describe its distribution across preoperative SS-OCT lenticular pattern categories (I, II, and III).

CDE will be obtained from the phacoemulsification system records and expressed in the units reported by the device.

Differences in CDE across lenticular pattern categories will be evaluated using statistical methods appropriate to the observed distribution of the data.

6 months
Interobserver and Intraobserver Reproducibility of SS-OCT Lenticular Pattern Classification
Periodo de tiempo: 6 months

Assessment of interobserver and intraobserver agreement in the classification of SS-OCT lenticular patterns (Types I-III), using percentage agreement and Cohen's kappa coefficient with 95% confidence intervals.

6 months
Incidence of Intraoperative Complications
Periodo de tiempo: 6 months

Assessment of the occurrence of intraoperative complications during cataract surgery and their association with preoperative SS-OCT lenticular patterns. Complication frequencies will be reported according to tomographic pattern classification.

6 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de mayo de 2026

Finalización primaria (Actual)

19 de octubre de 2026

Finalización del estudio (Actual)

19 de octubre de 2026

Fechas de registro del estudio

Enviado por primera vez

20 de octubre de 2026

Primero enviado que cumplió con los criterios de control de calidad

9 de noviembre de 2026

Publicado por primera vez (Actual)

16 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

16 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

9 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Términos MeSH relevantes adicionales

Otros números de identificación del estudio

  • 2020001-01
  • 2020001-01 (Otro identificador: Self-financed)

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

SÍ

Marco de tiempo para compartir IPD

In 6 months

Criterios de acceso compartido de IPD

Restricted access by request

Tipo de información de apoyo para compartir IPD

  • PROTOCOLO DE ESTUDIO
  • SAVIA
  • RSC

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

producto fabricado y exportado desde los EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir