Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

I-PRF Coating of Dental Implant Surfaces for Improving Implant Stability.

14 de noviembre de 2026 actualizado por: Damascus University

Evaluation of Injectable Platelet-Rich Fibrin (I-PRF) Coating of Implant Surfaces for Enhancing Implant Stability Compared With Conventional Implant Placement: A Randomized Controlled Clinical Trial.

This study was a double-blind, randomized controlled clinical trial with a split-mouth design, conducted among patients attending the Department of Oral and Maxillofacial Surgery and Dental Implant Clinics at the Faculty of Dentistry, Damascus University, between 2023 and 2025. The study aimed to evaluate whether coating the surface of dental implants with injectable platelet-rich fibrin (I-PRF) before implant placement could improve implant stability compared with conventional implant placement.

In the intervention group, the implant surface was coated with I-PRF before insertion, whereas implants in the control group were placed without I-PRF coating. The study included 10 implants in each group.

Implant stability was assessed using the Implant Stability Quotient (ISQ) with the Osseo 100® device. Measurements were recorded at five time points: immediately after implant placement and at 2, 4, 6, and 12 weeks after placement

Descripción general del estudio

Descripción detallada

Dental implant treatment has become an important component of modern dental practice for the rehabilitation of patients with partial or complete tooth loss. By restoring missing teeth, dental implants can contribute substantially to oral function, aesthetics, patient comfort, and oral health-related quality of life.

The long-term success of implant-supported rehabilitation depends on the establishment and maintenance of a stable biological and mechanical relationship between the implant and the surrounding bone.

Osseointegration is a fundamental biological process underlying the clinical success of dental implants. It involves the formation of a direct structural and functional connection between the implant surface and the surrounding living bone.

The quality and rate of osseointegration are influenced by several factors, including implant design, surface characteristics, surgical technique, bone quality and quantity, and local biological conditions. Consequently, considerable research has focused on modifying implant surfaces and improving the biological environment around newly placed implants in an attempt to facilitate bone healing and enhance implant stability.

Among the approaches investigated to improve the biological response to dental implants is the use of autologous platelet concentrates. Platelet-rich fibrin (PRF) is a second-generation platelet concentrate derived from the patient's own blood. It contains platelets, leukocytes, fibrin, and various biologically active substances that may contribute to tissue repair and regeneration.

Injectable platelet-rich fibrin (I-PRF) is a liquid form of PRF that can be applied to clinical sites before polymerization. Its handling characteristics allow it to be used in various regenerative applications, including the potential modification of the biological environment surrounding dental implants.

Coating the implant with an autologous biologically active material before insertion may provide a favorable local environment during the early stages of healing. The potential biological effects of I-PRF may be particularly relevant during the initial stages of bone healing, when cellular recruitment, vascularization, extracellular matrix formation, and subsequent bone formation take place around the implant.

Despite increasing interest in platelet concentrates and biological approaches to implant surface modification, the available evidence regarding the direct application of I-PRF as a coating on dental implant surfaces remains limited.

This study was therefore designed to investigate the potential effect of I-PRF coating of dental implant surfaces on implant stability compared with conventional implant placement. Implant stability was evaluated longitudinally from immediately after implant placement through the early healing period to assess the transition from primary to secondary implant stability. The study was conducted to determine whether this biological surface-treatment approach was associated with improved development of secondary implant stability compared with conventional implant placement.

Tipo de estudio

Intervencionista

Inscripción (Actual)

5

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Damascus, Siria, 0100
        • Department of Oral and Maxillofacial Surgery and Dental Implant Clinics, Faculty of Dentistry, Damascus University, Damascus, Syria.

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

42 años a 63 años (Adulto)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • The same inclusion criteria were applied to both study groups. Participants were eligible for inclusion if they met all of the following criteria:

    1. Good oral health.
    2. Age ≥18 years.
    3. Willingness to participate in the study after receiving adequate information about the study procedures and providing informed consent.
    4. Requirement for at least two symmetrical dental implants in the same jaw.
    5. No need for advanced surgical procedures, including sinus lift, bone splitting, or bone grafting procedures.
    6. Adequate primary implant stability, with an insertion torque of ≥20 N·cm, allowing implant placement in a single-stage surgical procedure.

Exclusion Criteria:

  • The same exclusion criteria were applied to both study groups. Participants were excluded if they met any of the following criteria:

    1. Systemic diseases that contraindicated implant surgery, such as cardiovascular disorders or coagulation disorders.
    2. Metabolic diseases that may affect normal bone metabolism, such as hyperparathyroidism or osteoporosis.
    3. Uncontrolled diabetes mellitus.
    4. Use of medications that may adversely affect healing, bone metabolism, or osseointegration, including corticosteroids, antiresorptive medications, or chemotherapeutic agents.
    5. Previous or current radiotherapy.
    6. Pregnancy.
    7. Current smoking or alcohol or illicit drug abuse.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: - The intervention group (I-PRF Group)

the surface of the dental implants (Dentis One Q®, Dentis Co., Ltd., South Korea) was coated with injectable platelet-rich fibrin (I-PRF) before insertion. (n = 10)

  • I-PRF Group: Before implant placement, 10 mL of venous blood was collected from the patient using a butterfly needle and transferred into a plain glass tube. The blood was then centrifuged at 800 rpm for 3 minutes. After centrifugation, the yellowish liquid fraction (I-PRF) was carefully aspirated from the upper layer of the tube using a 5-mL syringe. The I-PRF was then slowly applied to the entire surface of the dental implant, ensuring complete coating before insertion. The implant was subsequently placed according to the surgical protocol, with an insertion torque of 35 N·cm.
  • Conventional Group: The same type of dental implant was placed according to the standard surgical protocol, without I-PRF coating, with an insertion torque of 35 N·cm.
Sin intervención: - The control group: the same type of dental implants

(Dentis One Q®, Dentis Co., Ltd., South Korea) was placed without I-PRF coating. (n = 10)

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Implant Stability Quotient (ISQ)
Periodo de tiempo: Measurements were recorded at five time points: immediately after implant placement and at 2, 4, 6, and 12 weeks after placement.

Implant stability was assessed using the Implant Stability Quotient (ISQ) measured with the Osseo 100® device (NSK, Japan). ISQ values were recorded at five time points: immediately after implant placement (T0), and at 2 weeks (T1), 4 weeks (T2), 6 weeks (T3), and 12 weeks (T4) after implant placement.

For each implant, measurements were obtained in two perpendicular directions, and the mean of the two measurements was used for analysis. The primary outcome was the comparison of ISQ values between the I-PRF and conventional implant groups at each follow-up time point.

Measurements were recorded at five time points: immediately after implant placement and at 2, 4, 6, and 12 weeks after placement.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Director de estudio: Eisa Wehbeh, PhD in Oral and Maxillofacial, Faculty of Dentistry, Damascus University

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

3 de enero de 2023

Finalización primaria (Actual)

18 de diciembre de 2024

Finalización del estudio (Actual)

1 de marzo de 2025

Fechas de registro del estudio

Enviado por primera vez

14 de noviembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

14 de noviembre de 2026

Publicado por primera vez (Actual)

19 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

19 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

14 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Términos MeSH relevantes adicionales

Otros números de identificación del estudio

  • UDDS-2026-OMFS-18

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir