Assessment of Internal Fit and Marginal Adaptation of Inlay Zirconia Fixed Bridge Using Intraoral Versus Extraoral Scanner

17 de noviembre de 2026 actualizado por: Andrew Adel, October University for Modern Sciences and Arts

Assessment of Internal Fit and Marginal Adaptation of Inlay Zirconia Fixed Bridge Using Intra Oral Scanner Versus Extra Oral Scanner

This in vitro study aims to assess and compare the marginal adaptation and internal fit of inlay zirconia fixed bridges fabricated using intraoral scanning and extraoral scanning. The study will be performed on a Nissen typodont model. Prepared teeth replacing a missing lower first molar will be scanned using intraoral and extraoral scanning techniques. The resulting zirconia fixed bridges will be evaluated for marginal adaptation as the primary outcome and internal fit as the secondary outcome using a stereomicroscope.

Descripción general del estudio

Descripción detallada

Conventional fixed dental prostheses may require extensive reduction of healthy tooth structure. Inlay-retained fixed dental prostheses provide a more conservative approach by minimizing unnecessary removal of sound tooth structure. Digital scanning may simplify the workflow and reduce some of the limitations associated with conventional impression techniques.

This in vitro study will compare intraoral scanning (IOS) with extraoral scanning (EOS) for the fabrication of an inlay zirconia fixed bridge replacing a missing lower first molar. The study will be conducted on a Nissen typodont model. The prepared teeth will follow the guidelines for ceramic inlay preparation. Prepared samples fulfilling the eligibility criteria will be allocated into two groups in a 1:1 ratio using a computerized sequence generator.

The primary outcome will be marginal adaptation and the secondary outcome will be internal fit. Both outcomes will be measured using a stereomicroscope in micrometers (µm). The collected numerical data will be assessed for normality using the Kolmogorov-Smirnov and Shapiro-Wilk tests. The Mann-Whitney U test will be used to compare the two impression groups, while Friedman's test will be used to compare predetermined measurement points within each group. Dunn's test will be used for pairwise comparisons when Friedman's test is significant. The significance level will be set at P ≤ 0.05.

Tipo de estudio

Intervencionista

Inscripción (Actual)

32

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Giza Governorate
      • El-Sheikh Zayed City, Giza Governorate, Egipto, 12451
        • Faculty of Dentistry, October University for Modern Sciences and Arts (MSA)

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Niño
  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria

  • missing lower left 6
  • present lower left 5
  • present lower left 7

Exclusion Criteria:

  • present lower left 6
  • missing lower left 5
  • missing lower left 7

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Ciencia básica
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Intraoral Scanner (IOS)

Prepared typodont teeth for an inlay zirconia fixed bridge will be scanned using an intraoral scanner (IOS). The digital scan will be used for fabrication of the inlay zirconia fixed bridge, which will subsequently be evaluated for marginal adaptation and internal fit using a stereomicroscope.

Intraoral scanning of prepared typodont teeth for fabrication of an inlay zirconia fixed bridge. The digital scan obtained using the intraoral scanner will be used for the CAD/CAM fabrication of the restoration, which will then be evaluated for marginal adaptation and internal fit.

Comparador activo: * Extraoral Scanner (EOS)

Prepared typodont teeth for an inlay zirconia fixed bridge will be scanned using an extraoral scanner (EOS). The digital scan will be used for fabrication of the inlay zirconia fixed bridge, which will subsequently be evaluated for marginal adaptation and internal fit using a stereomicroscope.

Extraoral scanning of prepared typodont teeth for fabrication of an inlay zirconia fixed bridge. The digital scan obtained using the extraoral scanner will be used for the CAD/CAM fabrication of the restoration, which will then be evaluated for marginal adaptation and internal fit.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Marginal adaptation of the inlay zirconia fixed bridge
Periodo de tiempo: one day after trial insertion of the inlay zirconia fixed bridge

Marginal adaptation will be evaluated by measuring the marginal gap at predetermined points using a stereomicroscope. Measurements will be recorded in micrometers (µm).

one day after trial insertion of the inlay zirconia fixed bridge

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Internal fit of the inlay zirconia fixed bridg
Periodo de tiempo: one day after trial insertion of the inlay zirconia fixed bridge

Internal fit will be evaluated at predetermined points using a stereomicroscope. Measurements will be recorded in micrometers (µm).

one day after trial insertion of the inlay zirconia fixed bridge

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

17 de abril de 2024

Finalización primaria (Actual)

4 de julio de 2024

Finalización del estudio (Actual)

7 de enero de 2026

Fechas de registro del estudio

Enviado por primera vez

2 de septiembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

17 de noviembre de 2026

Publicado por primera vez (Actual)

24 de noviembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

24 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

17 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 18393

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir