- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT05185206
Comparative Evaluation of the Post Operative Sensitivity of Cention-N(Commercially Available Restorative Material) Using Conventional and Polymer Bur- In-vivo Study
Tutkimuksen yleiskatsaus
Tila
Yksityiskohtainen kuvaus
Dental caries is a multifactorial disease which is very much prevalent in India occurring especially in high economic group and some in middle and lower economic groups of world population.The most common instruments used for excavation of dental caries are the use of diamond and carbide burs.There is effective removal of the carious tooth structure through these burs which leads to excess removal of tooth structure and weakening the teeth.
Timely advancement in dentistry and the quest for the development of ideal esthetic materials to replace lost dental tissue has led to use of Cention-N(commercially available restorative material) to restore posterior teeth. Cention N(commerically available restorative material) is a recently introduced tooth-coloured, basic filling material for bulk placement in retentive preparations with or without the application of an adhesive. It is an alkise restorative which is a new category of filling material, like compomer(commercially available restorative material) or ormocer(commercially available restorative material) and is essentially a subgroup of the composite resin. Cention-N(commercially available restorative material)offers a cost-effective substitute for amalgam and also fulfills the need of an esthetic bulk fill material in the posterior region. Patients have described post-operative sensitivity as a moderate pain, of short duration, that appears spontaneously when chewing, with hot and cold foods and on rare occasions with sweet and acid foods, and it disappears when the stimulus is removed. It is characterized by an acute pain that can last for days or weeks and disappears when the stimulus is removed.It results from the interaction between the restorative technique, the clinical condition of the tooth to be treated (health of the pulp and remaining hard dental tissue) and the restorative material. Therefore, there is a permanent and unpredictable possibility of sensitivity occurring. In addition, there are other factors related to the cause of post- operative sensitivity, such as the individual profile of each patient, the shape and extension of the cavity preparation and protection of the dentin-pulp complex. Hence the novelty of this study is to evaluate of the post operative sensitivity of Cention-n (commerically available restorative material)using conventional and polymer bur.
Opintotyyppi
Ilmoittautuminen (Odotettu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
- Nimi: Soumya S Shetty, MDS
- Puhelinnumero: 8888200888
- Sähköposti: drsoumyasshetty@gmail.com
Opiskelupaikat
-
-
Maharashtra
-
Pune, Maharashtra, Intia, 411018
- Rekrytointi
- Dr D.Y. Patil Dental College and Hospital, Pimpri
-
Ottaa yhteyttä:
- Soumya S Shetty, MDS
- Puhelinnumero: 888820088
- Sähköposti: drsoumyasshetty@gmail.com
-
Ottaa yhteyttä:
- Riya A Parwani, BDS
- Puhelinnumero: 9922929705
- Sähköposti: riyaparwani2307@gmail.com
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Patients aged between 18 and 55 years having class 1 occlusal caries(1.2 according to G. J. Mount classification) on both sides of arch. In order to standardise the cavity preparation depth(approximately 1.5 to 2mm from the roof of the pulp chamber), the distance from occlusal surface to roof of pulp chamber will be used for measuring with the radiograph.
- Roots with closed apex.
- Systematically healthy patients.
- Patients with no other symptomatic tooth involved
Exclusion Criteria:
- Teeth with the presence of any pathologic pulpal disease with or without pain.
- Teeth with previous restorations, any defective restoration adjacent to or opposing the affected tooth.
- Teeth with surface loss due to attrition, erosion, abrasion, or abfraction.
- Patients with poor oral hygiene, severe, or chronic periodontitis.
- Patient on medication which may hinder the response to sensitivity.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Kolminkertaistaa
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Active Comparator: Analysis of post-operative sensitivity after caries removal using conventional steel bur
Caries will be excavated using a carbide on one side of the arch and restoration will be done with Cention-N(commercially available restorative material) as per manufacturer's instructions.Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity.
The pain intensity will be recorded with the Visual Analog Scale.
|
Patients aged between 18 and 55 years having class 1 occlusal caries(1.2
according to G. J. Mount classification) on both sides of arch.
In order to standardise the cavity preparation depth(approximately 1.5 to 2mm from the roof of the pulp chamber), the distance from occlusal surface to roof of pulp chamber will be used for measuring with the radiograph.
This will be followed by caries removal with convention steel bur followed by restoration with Cention-n and checking of postoperative sensitivity using Visual Analog Scale.The Visual Analog Scale consists of a 100-mm line divided into equal intervals of 10 mm, where 0 represents "absence of pain" and 100 "severe pain."
The results of Visual Analog Scale will be classified as mild (0-30 mm), moderate (40-70 mm), or severe pain (> 70 mm).
|
|
Kokeellinen: Analysis of post-operative sensitivity after caries removal using polymer bur
Caries will be excavated using a polymer on one side of the arch and restoration will be done with Cention-N(commercially available restorative material) as per manufacturer's instructions.Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity.
The pain intensity will be recorded with the Visual Analog Scale.
|
Patients aged between 18 and 55 years having class 1 occlusal caries(1.2
according to G. J. Mount classification) on both sides of arch.
In order to standardise the cavity preparation depth(approximately 1.5 to 2mm from the roof of the pulp chamber), the distance from occlusal surface to roof of pulp chamber will be used for measuring with the radiograph.
This will be followed by caries removal with polymer bur followed by restoration with Cention-n and checking of postoperative sensitivity using Visual Analog scale.The Visual Analog Scale consists of a 100-mm line divided into equal intervals of 10 mm, where 0 represents "absence of pain" and 100 "severe pain."
The results of Visual Analog Scale will be classified as mild (0-30 mm), moderate (40-70 mm), or severe pain (> 70 mm).
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Post-operative sensitivity checked using Visual Analog Scale by thermal stimulus.
Aikaikkuna: Post operative sensitivity will be checked after 24 hours.
|
Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity.
The pain intensity will be recorded with the visual analog scale (VAS).
|
Post operative sensitivity will be checked after 24 hours.
|
|
Post-operative sensitivity checked using Visual Analog Scale by thermal stimulus.
Aikaikkuna: Post operative sensitivity will be checked after 15 days.
|
Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity.
The pain intensity will be recorded with the visual analog scale (VAS).
|
Post operative sensitivity will be checked after 15 days.
|
|
Post-operative sensitivity checked using Visual Analog Scale by thermal stimulus.
Aikaikkuna: Post operative sensitivity will be checked after 30 days.
|
Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity.
The pain intensity will be recorded with the Visual Analog Scale.
|
Post operative sensitivity will be checked after 30 days.
|
Yhteistyökumppanit ja tutkijat
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Odotettu)
Opintojen valmistuminen (Odotettu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- DYPDCH/IEC/123/99/19
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .