Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Comparative Evaluation of the Post Operative Sensitivity of Cention-N(Commercially Available Restorative Material) Using Conventional and Polymer Bur- In-vivo Study

7 gennaio 2022 aggiornato da: Soumya Shetty, Dr. D. Y. Patil Dental College & Hospital
Cention-N(commercially available restorative material) is a cost effective restoration for posterior restorations. Post-operative sensitivity is of great concern as far as any type of restorative material is concerned. Reduction of post-operative sensitivity is still a major on-going research. Timely advancement has lead to the discovery and usage of polymer bur for reduction of excess tooth removal, and thus reduction of sensitivity. Therefore the novelty of this study is comparision of the post operative sensitivity of Cention-N(commercially available restorative material) using conventional and polymer bur using Visual Analog Scale.

Panoramica dello studio

Descrizione dettagliata

Dental caries is a multifactorial disease which is very much prevalent in India occurring especially in high economic group and some in middle and lower economic groups of world population.The most common instruments used for excavation of dental caries are the use of diamond and carbide burs.There is effective removal of the carious tooth structure through these burs which leads to excess removal of tooth structure and weakening the teeth.

Timely advancement in dentistry and the quest for the development of ideal esthetic materials to replace lost dental tissue has led to use of Cention-N(commercially available restorative material) to restore posterior teeth. Cention N(commerically available restorative material) is a recently introduced tooth-coloured, basic filling material for bulk placement in retentive preparations with or without the application of an adhesive. It is an alkise restorative which is a new category of filling material, like compomer(commercially available restorative material) or ormocer(commercially available restorative material) and is essentially a subgroup of the composite resin. Cention-N(commercially available restorative material)offers a cost-effective substitute for amalgam and also fulfills the need of an esthetic bulk fill material in the posterior region. Patients have described post-operative sensitivity as a moderate pain, of short duration, that appears spontaneously when chewing, with hot and cold foods and on rare occasions with sweet and acid foods, and it disappears when the stimulus is removed. It is characterized by an acute pain that can last for days or weeks and disappears when the stimulus is removed.It results from the interaction between the restorative technique, the clinical condition of the tooth to be treated (health of the pulp and remaining hard dental tissue) and the restorative material. Therefore, there is a permanent and unpredictable possibility of sensitivity occurring. In addition, there are other factors related to the cause of post- operative sensitivity, such as the individual profile of each patient, the shape and extension of the cavity preparation and protection of the dentin-pulp complex. Hence the novelty of this study is to evaluate of the post operative sensitivity of Cention-n (commerically available restorative material)using conventional and polymer bur.

Tipo di studio

Interventistico

Iscrizione (Anticipato)

20

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Luoghi di studio

    • Maharashtra
      • Pune, Maharashtra, India, 411018
        • Reclutamento
        • Dr D.Y. Patil Dental College and Hospital, Pimpri
        • Contatto:
        • Contatto:

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 55 anni (Adulto)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Patients aged between 18 and 55 years having class 1 occlusal caries(1.2 according to G. J. Mount classification) on both sides of arch. In order to standardise the cavity preparation depth(approximately 1.5 to 2mm from the roof of the pulp chamber), the distance from occlusal surface to roof of pulp chamber will be used for measuring with the radiograph.
  • Roots with closed apex.
  • Systematically healthy patients.
  • Patients with no other symptomatic tooth involved

Exclusion Criteria:

  • Teeth with the presence of any pathologic pulpal disease with or without pain.
  • Teeth with previous restorations, any defective restoration adjacent to or opposing the affected tooth.
  • Teeth with surface loss due to attrition, erosion, abrasion, or abfraction.
  • Patients with poor oral hygiene, severe, or chronic periodontitis.
  • Patient on medication which may hinder the response to sensitivity.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Triplicare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Analysis of post-operative sensitivity after caries removal using conventional steel bur
Caries will be excavated using a carbide on one side of the arch and restoration will be done with Cention-N(commercially available restorative material) as per manufacturer's instructions.Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity. The pain intensity will be recorded with the Visual Analog Scale.
Patients aged between 18 and 55 years having class 1 occlusal caries(1.2 according to G. J. Mount classification) on both sides of arch. In order to standardise the cavity preparation depth(approximately 1.5 to 2mm from the roof of the pulp chamber), the distance from occlusal surface to roof of pulp chamber will be used for measuring with the radiograph. This will be followed by caries removal with convention steel bur followed by restoration with Cention-n and checking of postoperative sensitivity using Visual Analog Scale.The Visual Analog Scale consists of a 100-mm line divided into equal intervals of 10 mm, where 0 represents "absence of pain" and 100 "severe pain." The results of Visual Analog Scale will be classified as mild (0-30 mm), moderate (40-70 mm), or severe pain (> 70 mm).
Sperimentale: Analysis of post-operative sensitivity after caries removal using polymer bur
Caries will be excavated using a polymer on one side of the arch and restoration will be done with Cention-N(commercially available restorative material) as per manufacturer's instructions.Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity. The pain intensity will be recorded with the Visual Analog Scale.
Patients aged between 18 and 55 years having class 1 occlusal caries(1.2 according to G. J. Mount classification) on both sides of arch. In order to standardise the cavity preparation depth(approximately 1.5 to 2mm from the roof of the pulp chamber), the distance from occlusal surface to roof of pulp chamber will be used for measuring with the radiograph. This will be followed by caries removal with polymer bur followed by restoration with Cention-n and checking of postoperative sensitivity using Visual Analog scale.The Visual Analog Scale consists of a 100-mm line divided into equal intervals of 10 mm, where 0 represents "absence of pain" and 100 "severe pain." The results of Visual Analog Scale will be classified as mild (0-30 mm), moderate (40-70 mm), or severe pain (> 70 mm).

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Post-operative sensitivity checked using Visual Analog Scale by thermal stimulus.
Lasso di tempo: Post operative sensitivity will be checked after 24 hours.
Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity. The pain intensity will be recorded with the visual analog scale (VAS).
Post operative sensitivity will be checked after 24 hours.
Post-operative sensitivity checked using Visual Analog Scale by thermal stimulus.
Lasso di tempo: Post operative sensitivity will be checked after 15 days.
Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity. The pain intensity will be recorded with the visual analog scale (VAS).
Post operative sensitivity will be checked after 15 days.
Post-operative sensitivity checked using Visual Analog Scale by thermal stimulus.
Lasso di tempo: Post operative sensitivity will be checked after 30 days.
Thermal stimulation (refrigerant spray Endo-Ice) will be used to evaluate the type of sensitivity. The pain intensity will be recorded with the Visual Analog Scale.
Post operative sensitivity will be checked after 30 days.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

2 maggio 2020

Completamento primario (Anticipato)

30 dicembre 2021

Completamento dello studio (Anticipato)

30 giugno 2022

Date di iscrizione allo studio

Primo inviato

12 dicembre 2021

Primo inviato che soddisfa i criteri di controllo qualità

7 gennaio 2022

Primo Inserito (Effettivo)

11 gennaio 2022

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

11 gennaio 2022

Ultimo aggiornamento inviato che soddisfa i criteri QC

7 gennaio 2022

Ultimo verificato

1 gennaio 2022

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • DYPDCH/IEC/123/99/19

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi