Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

CardioFlow Transcatheter Mitral Valve Replacement System Pre-market Clinical Investigation

maanantai 28. syyskuuta 2026 päivittänyt: Shanghai MicroPort CardioFlow Medtech Co., Ltd.

A Prospective, Multicenter, Single-arm Clinical Investigation for the Evaluation of Safety and Effectiveness of Microport CardioFlow Transcatheter Mitral Valve Replacement System in the Treatment of Moderate to Severe or Severe Symptomatic Mitral Regurgitation(CF-TMVR)

This is a prospective, multi-center, single-arm study to assess the safety and effectiveness of Microport CardioFlow Transcatheter Mitral Valve Replacement system in the treatment of moderate to severe or severe degenerative mitral regurgitation and to provide the clinical evidence for product registration in China or other countries

Tutkimuksen yleiskatsaus

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

152

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

      • Beijing, Kiina
      • Kunming, Kiina
      • Zhengzhou, Kiina

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

65 vuotta ja vanhemmat (Vanhempi Aikuinen)

Hyväksyy terveitä vapaaehtoisia

Ei

Sukupuolet, jotka voivat opiskella

Kaikki

Kuvaus

Subjects must meet all of the following criteria to be included in the study:

  • Subject has symptomatic, moderate-to-severe or severe, degenerative mitral regurgitation(MR≥3+);
  • NYHA functional class≥ II;
  • Heart team agrees that patient is unsuitable for treatment with conventional mitral valve surgery or transcatheter mitral valve edge-to-edge repair;
  • Subjects age ≥65 years old;
  • Subjects willing to sign Informed Consent for participation in the study and return for all required post-procedure follow-up visits;
  • Subjects anatomically suitable for the transcatheter mitral valve implantation

Subjects will be excluded from the study if any of the following conditions are present:

  • Left ventricular ejection fraction (LVEF)<30%;
  • Left ventricular end diastolic diameter (LVEDD)>7.5cm;
  • Cardiac echography evidence of intracardiac mass, thrombus, or vegetation;
  • Severe tricuspid regurgitation with severe right ventricular dysfunction or any tricuspid valve disease requiring surgery or transcatheter intervention;
  • Aortic valve diseases requiring surgery or transcatheter intervention;
  • Any prohibitive mitral annular calcification(annulus to the leaflet) interferes the expansion of the device;
  • Prior surgical treatment of mitral valve;
  • Therapeutic cardiac surgical or interventional procedure within 30 days prior to the index procedure;
  • End-stage heart failure requiring left ventricular assist device or cardiac transplantation
  • Subjects with severe major vascular disease requiring surgical intervention or with aortic dissection
  • Need for emergent surgery
  • Hypertrophic or restrictive cardiomyopathy, constrictive pericarditis
  • Mitral valve pathological anatomy,LVOT anatomy, left atrial or ventricle anatomy not applicable for the investigational device implantation;
  • Concurrent medical condition with a life expectancy of less than 12 months
  • Evidence of an acute myocardial infarction or untreated clinically significant coronary artery disease requiring revascularization within 30 days of enrollment.
  • Recent cerebrovascular events(ischemic or hemorrhage stroke, not including TIA) within 3 months of enrollment
  • Severe carotid stenosis( > 70%, both sides of carotid artery)
  • Any of the following: leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy if cannot be adequately treated;
  • Active endocarditis or active other infection
  • Active peptic ulcer or history of upper gastrointestinal bleeding within 3 months
  • Subject refuses the blood transfusion;
  • Known hypersensitivity or contraindication to nitinol (titanium or nickel),bovine product, PET(Polyethylene terephthalate), contrast media; Inability to tolerate anti-platelet or anticoagulants therapy; Contraindicated for transesophageal echocardiography (TEE)
  • Condition that prevents transapical access, such as chest malformation, ventricular aneurysm, apical thinning
  • Subjects with rheumatic mitral stenosis
  • Acute exacerbation of chronic obstructive pulmonary disease
  • Per heart team assessment, conditions that not suitable for transcatheter mitral valve replacement
  • Severe disabling Alzheimer's disease
  • Currently participating in an investigational drug or another device study that has not yet reached its primary endpoint

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Ei käytössä
  • Inventiomalli: Yksittäinen ryhmätehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: MicroPort CardioFlow Transcatheter Mitral Valve Replacement

Subjects with moderate to severe or severe degenerative mitral regurgitation will undergo transcatheter mitral valve replacement

Patients will undergo transcatheter mitral valve replacement using Microport CardioFlow Mitral Valve Replacement System. The device is delivered via a transapical approach under the guidance of medical imaging equipment; the valve product loaded within the delivery system is advanced to the mitral annulus and released, thereby replacing the native mitral valve with pathological changes in function or anatomy.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Aikaikkuna
Rate of cumulative all-cause mortality at 12 months post-procedure
Aikaikkuna: 12 months
12 months

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Rate of cumulative all-cause mortality at 30 days, 6 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of heart failure rehospitalization at 30 days, 6 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of disabling and non-disabling stroke at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of myocardial infarction at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of major assess site and vascular complications at 30 days, 6 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of major and above bleeding defined by MVARC at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of acute kidney injury (stage 2/3) at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of arrhythmias and conduction system disturbances at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of permanent pacemaker implantation at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of mitral valve reoperation at 30 days, 6 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Technical success rate defined by MVARC at immediate post procedure
Aikaikkuna: immediate post procedure
immediate post procedure
Device success rate defined by MVARC at 30 days post procedure
Aikaikkuna: 30 days post procedure
30 days post procedure
Procedural success rate defined by MVARC at 30 days
Aikaikkuna: 30 days
30 days
Bioprosthesis haemodynamic function
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years

Mitral regurgitation (paravalvular leak and intra-valvular regurgitation)

30 days, 6 months, 12 months and 2-5 years
Bioprosthesis haemodynamic function
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years

Mitral valve area

30 days, 6 months, 12 months and 2-5 years
Bioprosthesis haemodynamic function
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years

Mitral valve transvalvular pressure gradient

30 days, 6 months, 12 months and 2-5 years
Change in NYHA classification at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Change in QoL score from baseline at 30 days, 6 months, 12 months and 2-5 years as assessed by KCCQ
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years
30 days, 6 months, 12 months and 2-5 years
Change in 6 minute walk test at 30 days, 6 months, 12 months and 2-5 years
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years
30 days, 6 months, 12 months and 2-5 years
Rate of device-related technical failure issues and complications defined by MVARC at 30 days, 6 months, 12 months and 2-5 years post procedure
Aikaikkuna: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Tiistai 1. joulukuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Tiistai 1. tammikuuta 2030

Opintojen valmistuminen (Arvioitu)

Maanantai 1. tammikuuta 2035

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Maanantai 21. syyskuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Maanantai 28. syyskuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Maanantai 5. lokakuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Maanantai 5. lokakuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Maanantai 28. syyskuuta 2026

Viimeksi vahvistettu

Tiistai 1. syyskuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Muut tutkimustunnusnumerot

  • CF-TMVR-2026

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa