CardioFlow Transcatheter Mitral Valve Replacement System Pre-market Clinical Investigation

28. september 2026 oppdatert av: Shanghai MicroPort CardioFlow Medtech Co., Ltd.

A Prospective, Multicenter, Single-arm Clinical Investigation for the Evaluation of Safety and Effectiveness of Microport CardioFlow Transcatheter Mitral Valve Replacement System in the Treatment of Moderate to Severe or Severe Symptomatic Mitral Regurgitation(CF-TMVR)

This is a prospective, multi-center, single-arm study to assess the safety and effectiveness of Microport CardioFlow Transcatheter Mitral Valve Replacement system in the treatment of moderate to severe or severe degenerative mitral regurgitation and to provide the clinical evidence for product registration in China or other countries

Studieoversikt

Status

Har ikke rekruttert ennå

Studietype

Intervensjonell

Registrering (Antatt)

152

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

65 år og eldre (Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Subjects must meet all of the following criteria to be included in the study:

  • Subject has symptomatic, moderate-to-severe or severe, degenerative mitral regurgitation(MR≥3+);
  • NYHA functional class≥ II;
  • Heart team agrees that patient is unsuitable for treatment with conventional mitral valve surgery or transcatheter mitral valve edge-to-edge repair;
  • Subjects age ≥65 years old;
  • Subjects willing to sign Informed Consent for participation in the study and return for all required post-procedure follow-up visits;
  • Subjects anatomically suitable for the transcatheter mitral valve implantation

Subjects will be excluded from the study if any of the following conditions are present:

  • Left ventricular ejection fraction (LVEF)<30%;
  • Left ventricular end diastolic diameter (LVEDD)>7.5cm;
  • Cardiac echography evidence of intracardiac mass, thrombus, or vegetation;
  • Severe tricuspid regurgitation with severe right ventricular dysfunction or any tricuspid valve disease requiring surgery or transcatheter intervention;
  • Aortic valve diseases requiring surgery or transcatheter intervention;
  • Any prohibitive mitral annular calcification(annulus to the leaflet) interferes the expansion of the device;
  • Prior surgical treatment of mitral valve;
  • Therapeutic cardiac surgical or interventional procedure within 30 days prior to the index procedure;
  • End-stage heart failure requiring left ventricular assist device or cardiac transplantation
  • Subjects with severe major vascular disease requiring surgical intervention or with aortic dissection
  • Need for emergent surgery
  • Hypertrophic or restrictive cardiomyopathy, constrictive pericarditis
  • Mitral valve pathological anatomy,LVOT anatomy, left atrial or ventricle anatomy not applicable for the investigational device implantation;
  • Concurrent medical condition with a life expectancy of less than 12 months
  • Evidence of an acute myocardial infarction or untreated clinically significant coronary artery disease requiring revascularization within 30 days of enrollment.
  • Recent cerebrovascular events(ischemic or hemorrhage stroke, not including TIA) within 3 months of enrollment
  • Severe carotid stenosis( > 70%, both sides of carotid artery)
  • Any of the following: leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy if cannot be adequately treated;
  • Active endocarditis or active other infection
  • Active peptic ulcer or history of upper gastrointestinal bleeding within 3 months
  • Subject refuses the blood transfusion;
  • Known hypersensitivity or contraindication to nitinol (titanium or nickel),bovine product, PET(Polyethylene terephthalate), contrast media; Inability to tolerate anti-platelet or anticoagulants therapy; Contraindicated for transesophageal echocardiography (TEE)
  • Condition that prevents transapical access, such as chest malformation, ventricular aneurysm, apical thinning
  • Subjects with rheumatic mitral stenosis
  • Acute exacerbation of chronic obstructive pulmonary disease
  • Per heart team assessment, conditions that not suitable for transcatheter mitral valve replacement
  • Severe disabling Alzheimer's disease
  • Currently participating in an investigational drug or another device study that has not yet reached its primary endpoint

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: MicroPort CardioFlow Transcatheter Mitral Valve Replacement

Subjects with moderate to severe or severe degenerative mitral regurgitation will undergo transcatheter mitral valve replacement

Patients will undergo transcatheter mitral valve replacement using Microport CardioFlow Mitral Valve Replacement System. The device is delivered via a transapical approach under the guidance of medical imaging equipment; the valve product loaded within the delivery system is advanced to the mitral annulus and released, thereby replacing the native mitral valve with pathological changes in function or anatomy.

Hva måler studien?

Primære resultatmål

Resultatmål
Tidsramme
Rate of cumulative all-cause mortality at 12 months post-procedure
Tidsramme: 12 months
12 months

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Rate of cumulative all-cause mortality at 30 days, 6 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of heart failure rehospitalization at 30 days, 6 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of disabling and non-disabling stroke at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of myocardial infarction at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of major assess site and vascular complications at 30 days, 6 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of major and above bleeding defined by MVARC at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of acute kidney injury (stage 2/3) at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of arrhythmias and conduction system disturbances at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of permanent pacemaker implantation at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of mitral valve reoperation at 30 days, 6 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Technical success rate defined by MVARC at immediate post procedure
Tidsramme: immediate post procedure
immediate post procedure
Device success rate defined by MVARC at 30 days post procedure
Tidsramme: 30 days post procedure
30 days post procedure
Procedural success rate defined by MVARC at 30 days
Tidsramme: 30 days
30 days
Bioprosthesis haemodynamic function
Tidsramme: 30 days, 6 months, 12 months and 2-5 years

Mitral regurgitation (paravalvular leak and intra-valvular regurgitation)

30 days, 6 months, 12 months and 2-5 years
Bioprosthesis haemodynamic function
Tidsramme: 30 days, 6 months, 12 months and 2-5 years

Mitral valve area

30 days, 6 months, 12 months and 2-5 years
Bioprosthesis haemodynamic function
Tidsramme: 30 days, 6 months, 12 months and 2-5 years

Mitral valve transvalvular pressure gradient

30 days, 6 months, 12 months and 2-5 years
Change in NYHA classification at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Change in QoL score from baseline at 30 days, 6 months, 12 months and 2-5 years as assessed by KCCQ
Tidsramme: 30 days, 6 months, 12 months and 2-5 years
30 days, 6 months, 12 months and 2-5 years
Change in 6 minute walk test at 30 days, 6 months, 12 months and 2-5 years
Tidsramme: 30 days, 6 months, 12 months and 2-5 years
30 days, 6 months, 12 months and 2-5 years
Rate of device-related technical failure issues and complications defined by MVARC at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsramme: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. desember 2026

Primær fullføring (Antatt)

1. januar 2030

Studiet fullført (Antatt)

1. januar 2035

Datoer for studieregistrering

Først innsendt

21. september 2026

Først innsendt som oppfylte QC-kriteriene

28. september 2026

Først lagt ut (Faktiske)

5. oktober 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

5. oktober 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

28. september 2026

Sist bekreftet

1. september 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • CF-TMVR-2026

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .