CardioFlow Transcatheter Mitral Valve Replacement System Pre-market Clinical Investigation

28 september 2026 uppdaterad av: Shanghai MicroPort CardioFlow Medtech Co., Ltd.

A Prospective, Multicenter, Single-arm Clinical Investigation for the Evaluation of Safety and Effectiveness of Microport CardioFlow Transcatheter Mitral Valve Replacement System in the Treatment of Moderate to Severe or Severe Symptomatic Mitral Regurgitation(CF-TMVR)

This is a prospective, multi-center, single-arm study to assess the safety and effectiveness of Microport CardioFlow Transcatheter Mitral Valve Replacement system in the treatment of moderate to severe or severe degenerative mitral regurgitation and to provide the clinical evidence for product registration in China or other countries

Studieöversikt

Status

Har inte rekryterat ännu

Studietyp

Interventionell

Inskrivning (Beräknad)

152

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

65 år och äldre (Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Beskrivning

Subjects must meet all of the following criteria to be included in the study:

  • Subject has symptomatic, moderate-to-severe or severe, degenerative mitral regurgitation(MR≥3+);
  • NYHA functional class≥ II;
  • Heart team agrees that patient is unsuitable for treatment with conventional mitral valve surgery or transcatheter mitral valve edge-to-edge repair;
  • Subjects age ≥65 years old;
  • Subjects willing to sign Informed Consent for participation in the study and return for all required post-procedure follow-up visits;
  • Subjects anatomically suitable for the transcatheter mitral valve implantation

Subjects will be excluded from the study if any of the following conditions are present:

  • Left ventricular ejection fraction (LVEF)<30%;
  • Left ventricular end diastolic diameter (LVEDD)>7.5cm;
  • Cardiac echography evidence of intracardiac mass, thrombus, or vegetation;
  • Severe tricuspid regurgitation with severe right ventricular dysfunction or any tricuspid valve disease requiring surgery or transcatheter intervention;
  • Aortic valve diseases requiring surgery or transcatheter intervention;
  • Any prohibitive mitral annular calcification(annulus to the leaflet) interferes the expansion of the device;
  • Prior surgical treatment of mitral valve;
  • Therapeutic cardiac surgical or interventional procedure within 30 days prior to the index procedure;
  • End-stage heart failure requiring left ventricular assist device or cardiac transplantation
  • Subjects with severe major vascular disease requiring surgical intervention or with aortic dissection
  • Need for emergent surgery
  • Hypertrophic or restrictive cardiomyopathy, constrictive pericarditis
  • Mitral valve pathological anatomy,LVOT anatomy, left atrial or ventricle anatomy not applicable for the investigational device implantation;
  • Concurrent medical condition with a life expectancy of less than 12 months
  • Evidence of an acute myocardial infarction or untreated clinically significant coronary artery disease requiring revascularization within 30 days of enrollment.
  • Recent cerebrovascular events(ischemic or hemorrhage stroke, not including TIA) within 3 months of enrollment
  • Severe carotid stenosis( > 70%, both sides of carotid artery)
  • Any of the following: leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy if cannot be adequately treated;
  • Active endocarditis or active other infection
  • Active peptic ulcer or history of upper gastrointestinal bleeding within 3 months
  • Subject refuses the blood transfusion;
  • Known hypersensitivity or contraindication to nitinol (titanium or nickel),bovine product, PET(Polyethylene terephthalate), contrast media; Inability to tolerate anti-platelet or anticoagulants therapy; Contraindicated for transesophageal echocardiography (TEE)
  • Condition that prevents transapical access, such as chest malformation, ventricular aneurysm, apical thinning
  • Subjects with rheumatic mitral stenosis
  • Acute exacerbation of chronic obstructive pulmonary disease
  • Per heart team assessment, conditions that not suitable for transcatheter mitral valve replacement
  • Severe disabling Alzheimer's disease
  • Currently participating in an investigational drug or another device study that has not yet reached its primary endpoint

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: N/A
  • Interventionsmodell: Enskild gruppuppgift
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: MicroPort CardioFlow Transcatheter Mitral Valve Replacement

Subjects with moderate to severe or severe degenerative mitral regurgitation will undergo transcatheter mitral valve replacement

Patients will undergo transcatheter mitral valve replacement using Microport CardioFlow Mitral Valve Replacement System. The device is delivered via a transapical approach under the guidance of medical imaging equipment; the valve product loaded within the delivery system is advanced to the mitral annulus and released, thereby replacing the native mitral valve with pathological changes in function or anatomy.

Vad mäter studien?

Primära resultatmått

Resultatmått
Tidsram
Rate of cumulative all-cause mortality at 12 months post-procedure
Tidsram: 12 months
12 months

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Rate of cumulative all-cause mortality at 30 days, 6 months and 2-5 years post procedure
Tidsram: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of heart failure rehospitalization at 30 days, 6 months and 2-5 years post procedure
Tidsram: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of disabling and non-disabling stroke at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of myocardial infarction at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of major assess site and vascular complications at 30 days, 6 months and 2-5 years post procedure
Tidsram: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Rate of major and above bleeding defined by MVARC at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of acute kidney injury (stage 2/3) at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of arrhythmias and conduction system disturbances at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of permanent pacemaker implantation at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Rate of mitral valve reoperation at 30 days, 6 months and 2-5 years post procedure
Tidsram: 30 days, 6 months and 2-5 years post procedure
30 days, 6 months and 2-5 years post procedure
Technical success rate defined by MVARC at immediate post procedure
Tidsram: immediate post procedure
immediate post procedure
Device success rate defined by MVARC at 30 days post procedure
Tidsram: 30 days post procedure
30 days post procedure
Procedural success rate defined by MVARC at 30 days
Tidsram: 30 days
30 days
Bioprosthesis haemodynamic function
Tidsram: 30 days, 6 months, 12 months and 2-5 years

Mitral regurgitation (paravalvular leak and intra-valvular regurgitation)

30 days, 6 months, 12 months and 2-5 years
Bioprosthesis haemodynamic function
Tidsram: 30 days, 6 months, 12 months and 2-5 years

Mitral valve area

30 days, 6 months, 12 months and 2-5 years
Bioprosthesis haemodynamic function
Tidsram: 30 days, 6 months, 12 months and 2-5 years

Mitral valve transvalvular pressure gradient

30 days, 6 months, 12 months and 2-5 years
Change in NYHA classification at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure
Change in QoL score from baseline at 30 days, 6 months, 12 months and 2-5 years as assessed by KCCQ
Tidsram: 30 days, 6 months, 12 months and 2-5 years
30 days, 6 months, 12 months and 2-5 years
Change in 6 minute walk test at 30 days, 6 months, 12 months and 2-5 years
Tidsram: 30 days, 6 months, 12 months and 2-5 years
30 days, 6 months, 12 months and 2-5 years
Rate of device-related technical failure issues and complications defined by MVARC at 30 days, 6 months, 12 months and 2-5 years post procedure
Tidsram: 30 days, 6 months, 12 months and 2-5 years post procedure
30 days, 6 months, 12 months and 2-5 years post procedure

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

1 december 2026

Primärt slutförande (Beräknad)

1 januari 2030

Avslutad studie (Beräknad)

1 januari 2035

Studieregistreringsdatum

Först inskickad

21 september 2026

Först inskickad som uppfyllde QC-kriterierna

28 september 2026

Första postat (Faktisk)

5 oktober 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

5 oktober 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

28 september 2026

Senast verifierad

1 september 2026

Mer information

Termer relaterade till denna studie

Andra studie-ID-nummer

  • CF-TMVR-2026

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera