- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07961655
NxPFA vs. LEAD-PFA for Paroxysmal Atrial Fibrillation
Nanosecond Pulsed Electric Field Ablation Versus Microsecond Pulsed Electric Field Ablation for the Treatment of Paroxysmal Atrial Fibrillation: A Prospective, Single -Center, Randomized Controlled Clinical Study to Evaluate Efficacy, Safety And Operational Performance
**Brief Summary**
This study will compare two pulsed field ablation systems, NxPFA and LEAD-PFA, in people with paroxysmal atrial fibrillation, a type of irregular heart rhythm that comes and goes. Both systems use short electrical pulses to isolate the pulmonary veins, which can trigger atrial fibrillation. NxPFA delivers nanosecond pulses, while LEAD-PFA delivers microsecond pulses.
In this single-center study, participants will be randomly assigned to undergo ablation with one of the two systems. The study will compare how well the two systems prevent atrial fibrillation from returning and will assess their safety. It will also evaluate whether ablation can be completed without general anesthesia, how comfortable participants are during the procedure, and how easily the clinical team can perform the procedure with each system.
Tutkimuksen yleiskatsaus
Tila
Ehdot
Interventio / Hoito
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Age range: 18 - 80 years old;
- Diagnosed with drug-resistant, symptomatic paroxysmal atrial fibrillation through electrocardiogram or ambulatory electrocardiogram;
- Planning to undergo the first catheter ablation treatment; Sign a written informed consent form;
Exclusion Criteria:
- Previous history of left atrial catheter ablation or cardiac surgery.
- Anterior-posterior diameter of the left atrium > 50mm (measured by transthoracic echocardiography).
- Left ventricular ejection fraction < 40%.
- Presence of intracardiac thrombus (confirmed by transesophageal echocardiography or left atrial CT angiography).
- Complicated with other types of arrhythmias that require concurrent ablation (such as typical atrial flutter).
- Pregnant or lactating women.
- Presence of contraindications to anticoagulation or catheterization.
- Any other conditions judged by the researchers as unsuitable for participation in this study.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: NxPFA
|
The NxPFA system delivers nanosecond-duration pulsed electric fields via an ablation catheter to achieve pulmonary vein isolation in participants with paroxysmal atrial fibrillation. |
|
Active Comparator: LEAD-PFA
|
The LEAD-PFA system delivers microsecond-duration pulsed electric fields via an ablation catheter to achieve pulmonary vein isolation in participants with paroxysmal atrial fibrillation. |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
|---|---|
|
Percentage of Participants Free From Atrial Arrhythmia Recurrence
Aikaikkuna: From the end of the 3-month post-ablation blanking period through 12 months after ablation
|
From the end of the 3-month post-ablation blanking period through 12 months after ablation
|
|
Percentage of Participants With Device- or Procedure-Related Serious Adverse Events
Aikaikkuna: From completion of the ablation procedure through 12 months after ablation
|
From completion of the ablation procedure through 12 months after ablation
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- 2026-343
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .