NxPFA vs. LEAD-PFA for Paroxysmal Atrial Fibrillation
Nanosecond Pulsed Electric Field Ablation Versus Microsecond Pulsed Electric Field Ablation for the Treatment of Paroxysmal Atrial Fibrillation: A Prospective, Single -Center, Randomized Controlled Clinical Study to Evaluate Efficacy, Safety And Operational Performance
**Brief Summary**
This study will compare two pulsed field ablation systems, NxPFA and LEAD-PFA, in people with paroxysmal atrial fibrillation, a type of irregular heart rhythm that comes and goes. Both systems use short electrical pulses to isolate the pulmonary veins, which can trigger atrial fibrillation. NxPFA delivers nanosecond pulses, while LEAD-PFA delivers microsecond pulses.
In this single-center study, participants will be randomly assigned to undergo ablation with one of the two systems. The study will compare how well the two systems prevent atrial fibrillation from returning and will assess their safety. It will also evaluate whether ablation can be completed without general anesthesia, how comfortable participants are during the procedure, and how easily the clinical team can perform the procedure with each system.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Age range: 18 - 80 years old;
- Diagnosed with drug-resistant, symptomatic paroxysmal atrial fibrillation through electrocardiogram or ambulatory electrocardiogram;
- Planning to undergo the first catheter ablation treatment; Sign a written informed consent form;
Exclusion Criteria:
- Previous history of left atrial catheter ablation or cardiac surgery.
- Anterior-posterior diameter of the left atrium > 50mm (measured by transthoracic echocardiography).
- Left ventricular ejection fraction < 40%.
- Presence of intracardiac thrombus (confirmed by transesophageal echocardiography or left atrial CT angiography).
- Complicated with other types of arrhythmias that require concurrent ablation (such as typical atrial flutter).
- Pregnant or lactating women.
- Presence of contraindications to anticoagulation or catheterization.
- Any other conditions judged by the researchers as unsuitable for participation in this study.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: NxPFA
|
The NxPFA system delivers nanosecond-duration pulsed electric fields via an ablation catheter to achieve pulmonary vein isolation in participants with paroxysmal atrial fibrillation. |
|
Actieve vergelijker: LEAD-PFA
|
The LEAD-PFA system delivers microsecond-duration pulsed electric fields via an ablation catheter to achieve pulmonary vein isolation in participants with paroxysmal atrial fibrillation. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Percentage of Participants Free From Atrial Arrhythmia Recurrence
Tijdsspanne: From the end of the 3-month post-ablation blanking period through 12 months after ablation
|
From the end of the 3-month post-ablation blanking period through 12 months after ablation
|
|
Percentage of Participants With Device- or Procedure-Related Serious Adverse Events
Tijdsspanne: From completion of the ablation procedure through 12 months after ablation
|
From completion of the ablation procedure through 12 months after ablation
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2026-343
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .