NxPFA vs. LEAD-PFA for Paroxysmal Atrial Fibrillation
Nanosecond Pulsed Electric Field Ablation Versus Microsecond Pulsed Electric Field Ablation for the Treatment of Paroxysmal Atrial Fibrillation: A Prospective, Single -Center, Randomized Controlled Clinical Study to Evaluate Efficacy, Safety And Operational Performance
**Brief Summary**
This study will compare two pulsed field ablation systems, NxPFA and LEAD-PFA, in people with paroxysmal atrial fibrillation, a type of irregular heart rhythm that comes and goes. Both systems use short electrical pulses to isolate the pulmonary veins, which can trigger atrial fibrillation. NxPFA delivers nanosecond pulses, while LEAD-PFA delivers microsecond pulses.
In this single-center study, participants will be randomly assigned to undergo ablation with one of the two systems. The study will compare how well the two systems prevent atrial fibrillation from returning and will assess their safety. It will also evaluate whether ablation can be completed without general anesthesia, how comfortable participants are during the procedure, and how easily the clinical team can perform the procedure with each system.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age range: 18 - 80 years old;
- Diagnosed with drug-resistant, symptomatic paroxysmal atrial fibrillation through electrocardiogram or ambulatory electrocardiogram;
- Planning to undergo the first catheter ablation treatment; Sign a written informed consent form;
Exclusion Criteria:
- Previous history of left atrial catheter ablation or cardiac surgery.
- Anterior-posterior diameter of the left atrium > 50mm (measured by transthoracic echocardiography).
- Left ventricular ejection fraction < 40%.
- Presence of intracardiac thrombus (confirmed by transesophageal echocardiography or left atrial CT angiography).
- Complicated with other types of arrhythmias that require concurrent ablation (such as typical atrial flutter).
- Pregnant or lactating women.
- Presence of contraindications to anticoagulation or catheterization.
- Any other conditions judged by the researchers as unsuitable for participation in this study.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: NxPFA
|
The NxPFA system delivers nanosecond-duration pulsed electric fields via an ablation catheter to achieve pulmonary vein isolation in participants with paroxysmal atrial fibrillation. |
|
Comparatore attivo: LEAD-PFA
|
The LEAD-PFA system delivers microsecond-duration pulsed electric fields via an ablation catheter to achieve pulmonary vein isolation in participants with paroxysmal atrial fibrillation. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Percentage of Participants Free From Atrial Arrhythmia Recurrence
Lasso di tempo: From the end of the 3-month post-ablation blanking period through 12 months after ablation
|
From the end of the 3-month post-ablation blanking period through 12 months after ablation
|
|
Percentage of Participants With Device- or Procedure-Related Serious Adverse Events
Lasso di tempo: From completion of the ablation procedure through 12 months after ablation
|
From completion of the ablation procedure through 12 months after ablation
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 2026-343
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .