- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT01992939
The Effect of Heat on Blood and Oxygen Flow Readings Part 2
This is the second part of a research study in order to determine if using a specialized pulse oximetry probe with external heat pack will help obtain oxygen saturation (SaO2) and heart rate (HR) during monitoring for patients with peripheral vascular disease (PVD), vasoconstriction, and hypothermic extremities. The inability to obtain accurate SaO2 and pulse readings can lead to misdiagnosis, incorrect treatment, or procedures to be canceled. SaO2 and pulse readings are important to maintain patient stability during diagnostic testing, surgical procedures and monitoring while in critical care areas. Changes in SaO2 and pulse are important to monitor in order to be able to compensate for any decrease in patient oxygen saturations during hemodynamic monitoring.
The primary aim of this study is to determine if using a specialized pulse oximetry probe with external heat pack will improve oxygenation readings in order to obtain SaO2 and pulse readings in patients with PVD, vasoconstriction, and hypothermic extremities as compared to readings obtained from an arterial blood gas.
The hypothesis is using a specialized pulse oximetry probe with external heat pack will help obtain more accurate pulse oximetry readings consistent with values obtained with an arterial blood gas.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Pennsylvania
-
Pittsburgh, Pennsylvania, États-Unis, 15240
- VA Pittsburgh Healthcare System
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Age > 18 years
- Able to give informed consent
- Patients must be able to read and understand English.
- Patients scheduled to enter the VA Pittsburgh Healthcare System catheterization lab
Arm 2 of the study:
1. The PI will determine if patients have poor circulation due to obstruction of the large arteries in their arms and legs (peripheral vascular disease (PVD), narrowing of their blood vessels (vasoconstriction), or extremities (arms, legs, etc) that are at least 3 degrees Fahrenheit below their normal body temperature. If patients do have any of the following they will be considered for arm 2. If they do not they will be considered for arm 1.
Exclusion Criteria:
In addition to the exclusions mentioned above, patients with the following conditions will be excluded from the trial:
1. Inability or unwillingness to sign informed consent with free will and sound mind, as determined by a score of <11 on the Evaluation to Sign Consent Form.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Non randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: Non-Healthy Subjects arm
Subjects in this arm will have peripheral vascular disease (PVD), vasoconstriction, or hypothermic extremities and they will receive two pulse oximetry probes.
One probe will be a standard of care pulse oximetry probe and the second probe is the specialized pulse oximetry probe with external heat pack
|
Pulse oximetry will be obtained using the specialized pulse oximetry probe with external heat pack for 45 minutes.
Pulse oximetry will be obtained using a standard of care pulse oximetry probe for 45 minutes.
|
|
Comparateur actif: Healthy Subjects Arm
Subjects who do not have peripheral vascular disease (PVD), vasoconstriction, or hypothermic extremities will be considered healthy subjects and they will receive two pulse oximetry probes.
One probe will be a standard of care pulse oximetry probe and the second probe is the specialized pulse oximetry probe with external heat pack.
|
Pulse oximetry will be obtained using the specialized pulse oximetry probe with external heat pack for 45 minutes.
Pulse oximetry will be obtained using a standard of care pulse oximetry probe for 45 minutes.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
Pulse Oximetry
Délai: measured at least every 5 minutes - day 1
|
measured at least every 5 minutes - day 1
|
Mesures de résultats secondaires
Mesure des résultats |
Délai |
|---|---|
|
Arterial Blood Gas
Délai: measured once - day 1
|
measured once - day 1
|
Autres mesures de résultats
Mesure des résultats |
Délai |
|---|---|
|
Temperature
Délai: measured at least every 5 minutes - day 1
|
measured at least every 5 minutes - day 1
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Catherine Abee, CRT, VA Pittsburgh Healthcare System
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- PulsOx-002
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .