- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01992939
The Effect of Heat on Blood and Oxygen Flow Readings Part 2
This is the second part of a research study in order to determine if using a specialized pulse oximetry probe with external heat pack will help obtain oxygen saturation (SaO2) and heart rate (HR) during monitoring for patients with peripheral vascular disease (PVD), vasoconstriction, and hypothermic extremities. The inability to obtain accurate SaO2 and pulse readings can lead to misdiagnosis, incorrect treatment, or procedures to be canceled. SaO2 and pulse readings are important to maintain patient stability during diagnostic testing, surgical procedures and monitoring while in critical care areas. Changes in SaO2 and pulse are important to monitor in order to be able to compensate for any decrease in patient oxygen saturations during hemodynamic monitoring.
The primary aim of this study is to determine if using a specialized pulse oximetry probe with external heat pack will improve oxygenation readings in order to obtain SaO2 and pulse readings in patients with PVD, vasoconstriction, and hypothermic extremities as compared to readings obtained from an arterial blood gas.
The hypothesis is using a specialized pulse oximetry probe with external heat pack will help obtain more accurate pulse oximetry readings consistent with values obtained with an arterial blood gas.
Visão geral do estudo
Status
Condições
Descrição detalhada
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Pennsylvania
-
Pittsburgh, Pennsylvania, Estados Unidos, 15240
- VA Pittsburgh Healthcare System
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Age > 18 years
- Able to give informed consent
- Patients must be able to read and understand English.
- Patients scheduled to enter the VA Pittsburgh Healthcare System catheterization lab
Arm 2 of the study:
1. The PI will determine if patients have poor circulation due to obstruction of the large arteries in their arms and legs (peripheral vascular disease (PVD), narrowing of their blood vessels (vasoconstriction), or extremities (arms, legs, etc) that are at least 3 degrees Fahrenheit below their normal body temperature. If patients do have any of the following they will be considered for arm 2. If they do not they will be considered for arm 1.
Exclusion Criteria:
In addition to the exclusions mentioned above, patients with the following conditions will be excluded from the trial:
1. Inability or unwillingness to sign informed consent with free will and sound mind, as determined by a score of <11 on the Evaluation to Sign Consent Form.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
---|---|
Comparador Ativo: Non-Healthy Subjects arm
Subjects in this arm will have peripheral vascular disease (PVD), vasoconstriction, or hypothermic extremities and they will receive two pulse oximetry probes.
One probe will be a standard of care pulse oximetry probe and the second probe is the specialized pulse oximetry probe with external heat pack
|
Pulse oximetry will be obtained using the specialized pulse oximetry probe with external heat pack for 45 minutes.
Pulse oximetry will be obtained using a standard of care pulse oximetry probe for 45 minutes.
|
Comparador Ativo: Healthy Subjects Arm
Subjects who do not have peripheral vascular disease (PVD), vasoconstriction, or hypothermic extremities will be considered healthy subjects and they will receive two pulse oximetry probes.
One probe will be a standard of care pulse oximetry probe and the second probe is the specialized pulse oximetry probe with external heat pack.
|
Pulse oximetry will be obtained using the specialized pulse oximetry probe with external heat pack for 45 minutes.
Pulse oximetry will be obtained using a standard of care pulse oximetry probe for 45 minutes.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Prazo |
---|---|
Pulse Oximetry
Prazo: measured at least every 5 minutes - day 1
|
measured at least every 5 minutes - day 1
|
Medidas de resultados secundários
Medida de resultado |
Prazo |
---|---|
Arterial Blood Gas
Prazo: measured once - day 1
|
measured once - day 1
|
Outras medidas de resultado
Medida de resultado |
Prazo |
---|---|
Temperature
Prazo: measured at least every 5 minutes - day 1
|
measured at least every 5 minutes - day 1
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Catherine Abee, CRT, VA Pittsburgh Healthcare System
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- PulsOx-002
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .