Accuro Versus Traditional Landmark Palpation Technique to Determine Accurate Spinal Level for Procedures
Currently, at UVA, handheld ultrasound devices (like those used to view an unborn baby) are only two dimensional. The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures.
The investigators aim to assess the benefit of using the Accuro versus traditional landmark palpation technique to determine accurate spinal level for procedures. Patients who undergo interventional pain procedure per standard care under fluoroscopy and require the presence of an anesthesia provider at the UVA Pain Management Clinic will be approached for enrollment.
Anesthesia Providers will first identify the L4/L5 space using the traditional technique of palpating the iliac crests to estimate spinal level, which will be marked with a single dot from a marking pen. The provider will then use the Accuro 3000 to identify the L4/L5 interspace and mark this point with two dots. Participants will then be taken into the fluoroscopy suite for their scheduled procedure. Since the skin marks will not show up on fluoroscopy, and metal instrument will be laid on the skin at the interspace or interspaces that were marked using the palpation and Accuro techniques. The anesthesiology attending provider in the fluoroscopy suite will then confirm the true interspace position of these marks under fluoroscopy. It will then be recorded how many spaces off the palpation and Accuro techniques are from the intended L4/L5 level.
Aperçu de l'étude
Description détaillée
Patients who are undergoing any interventional pain procedure under fluoroscopy at the UVA Pain Management Clinic will be approached for consent.
- Each participant will sit up on the edge of the bed in the pre-procedural area of fluoroscopy.
- For each participant, a provider will first attempt to identify the L4/L5 space using the traditional technique of palpating the iliac crests to estimate spinal level. The provider will mark this space on the person's back with a single dot from a marking pen. The provider will then use the Accuro to again attempt to identify the L4/L5 interspace and mark this point with two dots.
- The participant will then be taken into the fluoroscopy suite for their scheduled procedure a metal instrument will be laid on the skin at the interspace or interspaces that were marked using the palpation and Accuro techniques. Metal instruments show up on fluoroscopy, but the skin markers will not.
- The anesthesiology attending in the fluoroscopy suite will then confirm the true interspace position of these marks under fluoroscopy performed for the standard of care procedure.
- The participant will not be exposed to any additional Fluro/ radiation time for this study
- It will then be recorded by the anesthesia provider, how many spaces off the palpation and Accuro techniques are from the intended L4/L5 level.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Virginia
-
Charlottesville, Virginia, États-Unis, 22908
- University of Virginia Health System
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- An anesthesia provider under fluoroscopy at the UVA Pain Management Clinic
Exclusion Criteria:
- Not meeting inclusion criteria
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
identify L4-5
Level marked as L4-5 using Accuro and palpation
|
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Accuracy in identifying the L4-L5 interspace using palpation versus ultrasound imaging (3D).
Délai: day one
|
whether there is a correlation between the landmark traditional technique versus US imaging.
Fluoroscopy will serve a s the control (gold standard)
|
day one
|
Collaborateurs et enquêteurs
Parrainer
Publications et liens utiles
Publications générales
- Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011 Jul;115(1):94-101. doi: 10.1097/ALN.0b013e31821a8ad4.
- Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8.
- Grau T, Bartusseck E, Conradi R, Martin E, Motsch J. Ultrasound imaging improves learning curves in obstetric epidural anesthesia: a preliminary study. Can J Anaesth. 2003 Dec;50(10):1047-50. doi: 10.1007/BF03018371.
- Grau T, Leipold RW, Conradi R, Martin E. Ultrasound control for presumed difficult epidural puncture. Acta Anaesthesiol Scand. 2001 Jul;45(6):766-71. doi: 10.1034/j.1399-6576.2001.045006766.x.
- Chin KJ, Karmakar MK, Peng P. Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade. Anesthesiology. 2011 Jun;114(6):1459-85. doi: 10.1097/ALN.0b013e318210f9f8.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 18684
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .