- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT03758092
Cardiovascular Screening in Infants Born Small for Gestational Age (CardioSGA)
Cardiovascular Screening in 2-year Old Infants Born Small for Gestational Age Compared With Infants Born Adequate for Gestational Age
Aperçu de l'étude
Statut
Les conditions
Description détaillée
We consecutively enrolled 20 SGA infants, born at term (37+0/41+3 week gestation), aged 24 months, and 20 AGA, age- and sex-matched controls. SGA was defined as a birth weight <10th percentile for sex, gestational age and birth order, and AGA as a birth weight between the 10th and the 90th percentile, according to Italian neonatal anthropometric charts.
Clinical and anthropometric variables The infants' prenatal and neonatal data were retrospectively recorded, namely a history of gestational diabetes and hypertension, the presence of intrauterine growth restriction, maternal weight gain during pregnancy, Apgar score, gestational age and birth weight, length, and head circumference. All subjects' parents completed a questionnaire including family history, maternal smoking during pregnancy, breastfeeding duration. At the time of enrollment (24 months), anthropometric data were evaluated by trained physicians according to standard procedures and based on the WHO growth charts. Height, weight, systolic (SBP) and diastolic (DBP) blood pressure were measured. Body mass index (BMI) was calculated as weight (kg)/height(cm)2 and weight gain in the first 2 years of life was calculated as the delta between birth weight and weight at 24 months.
Echocardiographic assessment Transthoracic echocardiogram using a Vivid 7 Pro ultrasound scanner (General Electric Healthcare, USA) was performed by an expert pediatric cardiologist, blinded to patients' clinical data. Measurements of left ventricle (LV end-diastolic diameter, LVEDD; LV end-systolic diameter, LVESD; interventricular septum at end diastole, IVSD; LV posterior wall at end diastole, LVPWD), relative wall thickness (RWT), left atrium diameter (LAD), the maximum LA volume, LV ejection fraction, and tricuspid annular plane systolic excursion (TAPSE) were obtained according to established standards. LV mass (LVM) was derived from the Devereux formula and indexed to body surface area (left ventricular mass index, LVMI). Left ventricular output (LVO) was obtained with the velocity time integral (VTI) from a 5-chamber view and calculated as follows LVO=[(VTI)x(heart rate)x(cross-sectional area)] and indexed to body weight.
Using pulsed wave Doppler, mitral inflow velocities, peak early diastolic velocity (E), peak late diastolic velocity (A), and E/A ratio, were measured. Pulsed wave tissue Doppler of the lateral mitral annulus was used for the measurement of early peak diastolic mitral annular velocity (E'). The E/E' ratio was calculated. End-diastolic pressure (EDP) was calculated from the E/E' ratio with the formula EDP=1.91+1.24xE/E' (14) and the pressure-volume curve during diastole with the formula EDP = αxEDVβ (end-diastolic volume, EDV). Volume parameters were corrected to fixed values of EDP (V30 mmHg). The coefficient "β" (Beta), indicating the slope of the end-diastolic pressure-volume relationship (EDPVR), was calculated with the formula β=[Log10(EDP/30)]/[Log10(EDV/V30mmHg)].
Vascular assessment Vascular measurements were performed with a high-resolution ultrasonography (Esaote MyLab25TM Gold, Esaote, Italy) using a 8 mHz linear transducer and a 5 mHz convex transducer for the abdominal aorta, by an expert vascular surgeon blinded to patients' clinical status. CIMT, abdominal aortic diameter at maximum systolic expansion (Ds) and minimum diastolic expansion (Dd), brachial artery diameters, brachial artery peak systolic velocity (PSV) and end diastolic velocity (EDV) were measured as previously described and aortic strain (S), pressure strain elastic modulus (Ep), pressure strain normalized by diastolic pressure (Ep*) and brachial artery flow-mediated dilation (FMD) were calculated. While S is the mean strain of the aortic wall, Ep and Ep* are the mean stiffness (16). Arterial wall stiffness index (β index) was calculated with the formula: β index=ln(SBP/DBP)/[(Ds-Dd) /Dd)] (17) and systemic vascular resistance (dynes/s/cm2) with the formula: SVR=(mean BP- right atrial pressure)/LVO, with an estimated right atrial pressure of 5 mmHg. The brachial artery maximum diameter recorded following reactive hyperemia was reported as a percentage change of resting diameter (FMD = peak diameter - baseline diameter/baseline diameter).
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
-
Novara, Italie, 28100
- AOU Maggiore della Carità - Clinica Pediatrica - Ambulatorio di Auxologia ed Endocrinologia Pediatrica
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- infants, 24-month old, born at term SGA or AGA
Exclusion Criteria:
- heart, respiratory, liver and kidney diseases, congenital malformations, genetic diseases, neonatal asphyxia, parenteral nutrition, congenital inborn errors of metabolism, and preterm and twin birth.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
|---|
|
SGA vs AGA infants
infants, born at term (37+0/41+3 week gestation), aged 24 months, with a birth weight <10th percentile or between 10th and 90th percentile for sex, gestational age, and birth order, according to Italian neonatal anthropometric charts
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Cardiovascular structure
Délai: 24 months
|
Heart structure
|
24 months
|
|
Cardiovascular function
Délai: 24 months
|
Heart function
|
24 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
catch-up growth
Délai: 24 months
|
delta between body weight at 24 months and birth weight
|
24 months
|
|
breastfeeding duration
Délai: 24 months
|
breastfeeding duration
|
24 months
|
Collaborateurs et enquêteurs
Publications et liens utiles
Publications générales
- Barker DJ, Osmond C, Golding J, Kuh D, Wadsworth ME. Growth in utero, blood pressure in childhood and adult life, and mortality from cardiovascular disease. BMJ. 1989 Mar 4;298(6673):564-7. doi: 10.1136/bmj.298.6673.564.
- Ong KK, Ahmed ML, Emmett PM, Preece MA, Dunger DB. Association between postnatal catch-up growth and obesity in childhood: prospective cohort study. BMJ. 2000 Apr 8;320(7240):967-71. doi: 10.1136/bmj.320.7240.967. Erratum In: BMJ 2000 May 6;320(7244):1244.
- Faienza MF, Brunetti G, Delvecchio M, Zito A, De Palma F, Cortese F, Nitti A, Massari E, Gesualdo M, Ricci G, Carbonara S, Giordano P, Cavallo L, Scicchitano P, Ciccone MM. Vascular Function and Myocardial Performance Indices in Children Born Small for Gestational Age. Circ J. 2016;80(4):958-63. doi: 10.1253/circj.CJ-15-1038. Epub 2016 Feb 10.
- Iruretagoyena JI, Gonzalez-Tendero A, Garcia-Canadilla P, Amat-Roldan I, Torre I, Nadal A, Crispi F, Gratacos E. Cardiac dysfunction is associated with altered sarcomere ultrastructure in intrauterine growth restriction. Am J Obstet Gynecol. 2014 Jun;210(6):550.e1-7. doi: 10.1016/j.ajog.2014.01.023. Epub 2014 Jan 16.
- Crispi F, Bijnens B, Figueras F, Bartrons J, Eixarch E, Le Noble F, Ahmed A, Gratacos E. Fetal growth restriction results in remodeled and less efficient hearts in children. Circulation. 2010 Jun 8;121(22):2427-36. doi: 10.1161/CIRCULATIONAHA.110.937995. Epub 2010 May 24.
- Dratva J, Breton CV, Hodis HN, Mack WJ, Salam MT, Zemp E, Gilliland F, Kuenzli N, Avol E. Birth weight and carotid artery intima-media thickness. J Pediatr. 2013 May;162(5):906-11.e1-2. doi: 10.1016/j.jpeds.2012.10.060. Epub 2012 Dec 20.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- CE 106/18
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .