Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Comparison of Single-Layer and Triple-Layer TPU MaxFlex Aligners After Intraoral Use (TPU-ALIGN)

27 avril 2026 mis à jour par: Abdul Qadir, Ayub Medical College, Abbottabad

Effects of Intraoral Aging on Mechanical Properties and Surface Morphology of Single-Layer Versus Triple-Layer Thermoplastic Polyurethane (TPU) MaxFlex Aligner Sheets: A Randomized Controlled Trial

This study aims to compare two types of clear orthodontic aligner materials used in dental treatment: single-layer and triple-layer thermoplastic polyurethane (TPU) aligners (MaxFlex). Clear aligners are commonly used to straighten teeth and are preferred for their comfort and aesthetic appearance.

Participants will be provided with aligners and instructed to wear them for approximately 22 hours per day for 10 days. The aligners will be collected before use and after the 10-day period. The study will evaluate how the oral environment affects the properties of these materials over time.

Laboratory tests will be conducted to measure mechanical properties such as strength, flexibility, and deformation, as well as to examine surface changes under a microscope. The results of this study may help improve the performance and durability of aligners and contribute to better orthodontic treatment outcomes.

Aperçu de l'étude

Description détaillée

Clear aligner therapy (CAT) has become an increasingly popular alternative to fixed orthodontic appliances due to its aesthetic advantages, improved patient comfort, and ease of oral hygiene maintenance. Thermoplastic materials, particularly thermoplastic polyurethane (TPU), are widely used in the fabrication of aligners due to their favorable mechanical and elastic properties.

Recent advancements in aligner materials have led to the development of multilayer TPU systems designed to enhance flexibility, force delivery, and clinical performance. Triple-layer TPU aligners typically consist of a soft inner layer for patient comfort, a rigid intermediate layer for structural strength, and a flexible outer layer to improve adaptability and fit. In contrast, single-layer TPU aligners are composed of a homogeneous material and are generally more cost-effective.

Despite these developments, limited evidence exists regarding the comparative behavior of single-layer and multilayer TPU materials following intraoral exposure. The oral environment, characterized by temperature fluctuations, moisture, masticatory forces, and enzymatic activity, may contribute to material degradation, potentially affecting aligner performance.

This randomized controlled trial is designed to evaluate the effects of intraoral aging on the mechanical properties and surface morphology of single-layer and triple-layer TPU aligners (MaxFlex). Participants will be randomly assigned to receive one type of aligner material and will be instructed to wear the aligners for a standardized duration of 10 days (minimum 22 hours per day).

Aligners will be collected at baseline (prior to intraoral use) and after the 10-day wear period. Following retrieval, samples will undergo standardized cleaning procedures before laboratory analysis.

Mechanical testing will be performed using dynamic mechanical analysis to assess tensile properties, stress relaxation behavior, and creep characteristics. Surface morphology will be evaluated using scanning electron microscopy to identify features such as roughness, cracks, and voids. Additionally, Fourier transform infrared spectroscopy will be used to detect potential chemical changes in the material composition.

The primary objective of this study is to compare the mechanical performance of single-layer and triple-layer TPU aligners before and after intraoral use. Secondary outcomes include evaluation of surface morphology and chemical structure changes associated with intraoral aging.

The findings of this study are expected to provide insight into the durability and clinical performance of different aligner materials, which may help guide material selection and improve orthodontic treatment outcomes.

Type d'étude

Interventionnel

Inscription (Réel)

66

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Punjab Province
      • Lahore, Punjab Province, Pakistan
        • Akhtar Saeed Medical & Dental College

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

Patients aged 18-30 years Fully erupted permanent dentition Good periodontal health Patients undergoing orthodontic treatment with clear aligners Mild crowding or spacing requiring labiolingual tooth movement Willingness to wear aligners for at least 22 hours per day Provision of informed consent

Exclusion Criteria:

Use of aligners from manufacturers other than study-specific TPU aligners Damaged or fractured aligners Poor compliance (wear time less than 22 hours/day) Presence of parafunctional habits (e.g., bruxism) Hypodontia or partially erupted dentition Cases involving bonded attachments on maxillary incisors Cases requiring rotational movement of maxillary incisors Patients with systemic or oral conditions affecting saliva composition or the oral environment

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Autre
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Single-Layer TPU Aligner Group
Participants in this group will receive single-layer thermoplastic polyurethane (TPU) MaxFlex aligners. The aligners will be worn intraorally for 10 days for a minimum of 22 hours per day under standardized conditions. Aligners will be collected at baseline and after the wear period for evaluation of mechanical properties and surface morphology.
Single-layer thermoplastic polyurethane (TPU) clear aligners fabricated from a homogeneous TPU sheet using thermoforming techniques. These aligners are designed to deliver orthodontic forces for tooth movement. Participants will be instructed to wear the aligners intraorally for 10 days for a minimum of 22 hours per day. The aligners will be evaluated before use and after intraoral exposure to assess changes in mechanical properties and surface morphology.
Expérimental: Triple-Layer TPU Aligner Group
Participants in this group will receive triple-layer thermoplastic polyurethane (TPU) MaxFlex aligners consisting of a soft inner layer, a rigid intermediate layer, and a flexible outer layer. The aligners will be worn intraorally for 10 days for a minimum of 22 hours per day. Aligners will be collected at baseline and after use for mechanical and surface analysis.
Triple-layer thermoplastic polyurethane (TPU) clear aligners composed of a multilayer structure including a soft inner layer, a rigid intermediate layer, and a flexible outer layer. These aligners are fabricated using thermoforming techniques and are designed to provide improved force delivery and adaptability. Participants will wear the aligners intraorally for 10 days for at least 22 hours per day. Pre- and post-use evaluations will be conducted to assess mechanical properties and surface morphology changes.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Effect of Oral Environment on Elastic Modulus of TPU Aligners
Délai: Baseline (0 week) and after 2 weeks of intraoral use (minimum 22 hours/day)
This outcome measures the change in elastic modulus (MPa) of thermoplastic polyurethane (TPU) orthodontic aligners following intraoral exposure. Measurements are obtained using a dynamic mechanical analyzer and compared between single-layer and multilayer TPU aligners at baseline and after two weeks of clinical use to assess changes in stiffness and material integrity.
Baseline (0 week) and after 2 weeks of intraoral use (minimum 22 hours/day)
Effect of Oral Environment on Stress Relaxation of TPU Aligners
Délai: Time Frame: Baseline (0 week) and after 2 weeks of intraoral use (minimum 22 hours/day)
This outcome measures the percentage stress relaxation (%) of TPU aligners following intraoral exposure. Stress decay over time is recorded using a dynamic mechanical analyzer and compared between single-layer and multilayer TPU aligners at baseline and after two weeks to evaluate force retention capacity.
Time Frame: Baseline (0 week) and after 2 weeks of intraoral use (minimum 22 hours/day)
Effect of Oral Environment on Creep Behavior of TPU Aligners
Délai: Time Frame: Baseline (0 week) and after 2 weeks of intraoral use (minimum 22 hours/day)
This outcome measures creep (% strain) in TPU aligners under constant stress conditions using a dynamic mechanical analyzer. Comparisons are made between single-layer and multilayer TPU aligners at baseline and after two weeks to assess susceptibility to permanent deformation.
Time Frame: Baseline (0 week) and after 2 weeks of intraoral use (minimum 22 hours/day)

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

13 septembre 2025

Achèvement primaire (Réel)

5 mars 2026

Achèvement de l'étude (Réel)

16 mars 2026

Dates d'inscription aux études

Première soumission

19 avril 2026

Première soumission répondant aux critères de contrôle qualité

27 avril 2026

Première publication (Réel)

5 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

27 avril 2026

Dernière vérification

1 septembre 2025

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • TPU-ALIGNER-01
  • no identifier (Autre identifiant: Akhtar Saeed Medical & Dental College)

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner