Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

A Novel Two-Tooth Clip for ESD and EFTR of GIST

Efficacy and Safety of a Novel Two-Tooth Clip-Assisted ESD and EFTR of GIST: A Single-Center, Prospective, Open-Label, Randomized Controlled Study

This study is designed to evaluate the efficacy and safety of a novel two-tooth endoscopic clip, utilized in a "clip with line" traction configuration, during endoscopic resection procedures (ESD and EFTR) of GIST. The novel clip's dual-tooth design is intended to provide a more secure anchor on the lesion, enabling effective counter-traction when combined with a line. The primary aim is to determine if this method improves submucosal dissection efficiency compared to conventional ESD. A secondary aim is to evaluate the performance of the same clip system for full-thickness or mucosal defect closure.

Aperçu de l'étude

Description détaillée

Endoscopic Submucosal Dissection (ESD) and Endoscopic Full-Thickness Resection (EFTR) are established, minimally invasive techniques for the en-bloc resection of gastrointestinal stromal tumor (GIST). However, a persistent challenge, especially in difficult locations or large lesions, is the lack of sufficient counter-traction, which leads to prolonged procedure times, increased risk of intraoperative bleeding, and potential for incomplete resection due to poor visualization of the submucosal layer. Furthermore, managing large post resection defects or perforations requires reliable and technically feasible endoscopic suturing.

This study introduces a novel two-tooth clip. The device's geometry is hypothesized to provide a stronger, more stable grasp on the targeted tissue compared to standard single-tooth or non-toothed clips. The study will investigate two sequential applications of this clip within a single procedure:

The Traction Phase: A "clip with line" technique will be employed. The novel two-tooth clip will be anchored to the proximal edge of the lesion. A dental line, pre-tied to the clip, will be used by the endoscopist to apply adjustable counter-traction. This is intended to lift the lesion, tauten the submucosal fibers, and clearly expose the dissection plane, thereby simulating the principle of surgical counter-traction.

The Closure Phase: Following lesion resection, the novel two-tooth clip will be utilized to perform a continuous, circumferential closure of the mucosal defect or perforation. The study will assess the technical success rate, time required for complete closure, and the clip's ability to securely approximate tissue layers.

Type d'étude

Interventionnel

Inscription (Estimé)

60

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Yan Liu, M.D., Ph.D.
  • Numéro de téléphone: +86-010-66947473
  • E-mail: 13911798288@163.com

Sauvegarde des contacts de l'étude

  • Nom: Min Min, M.D., Ph.D.
  • Numéro de téléphone: +86-010-66947473
  • E-mail: minmin823@sina.com

Lieux d'étude

      • Beijing, Chine, 100071
        • Recrutement
        • The Fifth Medical Center of Chinese PLA General Hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Age ≥ 18 and ≤ 85 years.
  • Patients diagnosed with gastric gastrointestinal lesions clinically indicated for ESD or EFTR.
  • Lesion size between 2 cm and 5 cm in diameter.
  • Willing and able to provide written informed consent.

Exclusion Criteria:

  • Lesions with clear evidence of deep submucosal invasion or distant metastasis precluding curative endoscopic resection.
  • Severe coagulation dysfunction (international normalized ratio >2.0, platelet count <50,000/µL) or ongoing use of dual antiplatelet therapy/anticoagulants that cannot be appropriately bridged or discontinued per guidelines.
  • Severe organ failure (cardiac, renal, hepatic, or respiratory) rendering the patient unsuitable for prolonged sedation or general anesthesia.
  • Pregnancy or lactation.
  • Prior surgical or endoscopic intervention at the target lesion site that results in significant fibrosis.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Novel Clip-Assisted Traction ESD/EFTR
Patients will undergo ESD or EFTR using the "clip with line" traction method with the novel two-tooth clip. After initial circumferential mucosal incision, the two-tooth clip (with pre-tied line) will be anchored to the lesion. The endoscopist will apply continuous or intermittent traction via the line to optimize the submucosal view. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips in a purse-string configuration.
"Clip with line" traction method with the novel two-tooth clip will be applied in patients undergoing ESD or EFTR. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips.
Comparateur actif: Conventional ESD/EFTR
Patients will undergo standard ESD or EFTR without the use of dedicated traction devices. The endoscopist may use transparent cap assistance and positional changes for exposure, which is current standard practice.
Standard ESD or EFTR without the use of dedicated traction devices will be performed, then using the standard clips for closure.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Submucosal Dissection Efficiency
Délai: 24 hours
The rate of submucosal dissection (measured in mm²/min), calculated from the start of submucosal entry to the completion of lesion removal.
24 hours

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Technical Success Rate of Purse-String Closure
Délai: 24 hours
Percentage of cases where complete, circumferential mucosal/full-thickness defect closure is achieved using the novel two-tooth clip without conversion to alternative closure devices.
24 hours
Defect Closure Time
Délai: 24 hours
Time taken to achieve complete purse-string closure of the post-resection defect.
24 hours
Incidence of Intraoperative Adverse Events
Délai: 3 days
  • Rates of immediate perforation (unintended) in both groups during the dissection phase
  • Rates of significant active bleeding requiring emergency hemostasis (aside from planned vessel coagulation) in both groups during the dissection phase
  • Rates of muscularis injury in both groups during the dissection phase
3 days
Post-procedural Outcomes
Délai: 3 months
  • Rates of delayed bleeding within 90 days
  • Rates of delayed perforation within 90 days
  • Rates of post-polypectomy electrocoagulation syndrome within 90 days
3 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Yan Liu, M.D.,Ph.D., Beijing 302 Hospital

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

24 avril 2026

Achèvement primaire (Estimé)

24 avril 2027

Achèvement de l'étude (Estimé)

1 juillet 2027

Dates d'inscription aux études

Première soumission

6 mai 2026

Première soumission répondant aux critères de contrôle qualité

6 mai 2026

Première publication (Réel)

12 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

22 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

20 mai 2026

Dernière vérification

1 mai 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner