Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

A Novel Two-Tooth Clip for ESD and EFTR of GIST

Efficacy and Safety of a Novel Two-Tooth Clip-Assisted ESD and EFTR of GIST: A Single-Center, Prospective, Open-Label, Randomized Controlled Study

This study is designed to evaluate the efficacy and safety of a novel two-tooth endoscopic clip, utilized in a "clip with line" traction configuration, during endoscopic resection procedures (ESD and EFTR) of GIST. The novel clip's dual-tooth design is intended to provide a more secure anchor on the lesion, enabling effective counter-traction when combined with a line. The primary aim is to determine if this method improves submucosal dissection efficiency compared to conventional ESD. A secondary aim is to evaluate the performance of the same clip system for full-thickness or mucosal defect closure.

Studie Overzicht

Gedetailleerde beschrijving

Endoscopic Submucosal Dissection (ESD) and Endoscopic Full-Thickness Resection (EFTR) are established, minimally invasive techniques for the en-bloc resection of gastrointestinal stromal tumor (GIST). However, a persistent challenge, especially in difficult locations or large lesions, is the lack of sufficient counter-traction, which leads to prolonged procedure times, increased risk of intraoperative bleeding, and potential for incomplete resection due to poor visualization of the submucosal layer. Furthermore, managing large post resection defects or perforations requires reliable and technically feasible endoscopic suturing.

This study introduces a novel two-tooth clip. The device's geometry is hypothesized to provide a stronger, more stable grasp on the targeted tissue compared to standard single-tooth or non-toothed clips. The study will investigate two sequential applications of this clip within a single procedure:

The Traction Phase: A "clip with line" technique will be employed. The novel two-tooth clip will be anchored to the proximal edge of the lesion. A dental line, pre-tied to the clip, will be used by the endoscopist to apply adjustable counter-traction. This is intended to lift the lesion, tauten the submucosal fibers, and clearly expose the dissection plane, thereby simulating the principle of surgical counter-traction.

The Closure Phase: Following lesion resection, the novel two-tooth clip will be utilized to perform a continuous, circumferential closure of the mucosal defect or perforation. The study will assess the technical success rate, time required for complete closure, and the clip's ability to securely approximate tissue layers.

Studietype

Ingrijpend

Inschrijving (Geschat)

60

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Contact Back-up

Studie Locaties

      • Beijing, China, 100071
        • Werving
        • The Fifth Medical Center of Chinese PLA General Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • Age ≥ 18 and ≤ 85 years.
  • Patients diagnosed with gastric gastrointestinal lesions clinically indicated for ESD or EFTR.
  • Lesion size between 2 cm and 5 cm in diameter.
  • Willing and able to provide written informed consent.

Exclusion Criteria:

  • Lesions with clear evidence of deep submucosal invasion or distant metastasis precluding curative endoscopic resection.
  • Severe coagulation dysfunction (international normalized ratio >2.0, platelet count <50,000/µL) or ongoing use of dual antiplatelet therapy/anticoagulants that cannot be appropriately bridged or discontinued per guidelines.
  • Severe organ failure (cardiac, renal, hepatic, or respiratory) rendering the patient unsuitable for prolonged sedation or general anesthesia.
  • Pregnancy or lactation.
  • Prior surgical or endoscopic intervention at the target lesion site that results in significant fibrosis.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Novel Clip-Assisted Traction ESD/EFTR
Patients will undergo ESD or EFTR using the "clip with line" traction method with the novel two-tooth clip. After initial circumferential mucosal incision, the two-tooth clip (with pre-tied line) will be anchored to the lesion. The endoscopist will apply continuous or intermittent traction via the line to optimize the submucosal view. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips in a purse-string configuration.
"Clip with line" traction method with the novel two-tooth clip will be applied in patients undergoing ESD or EFTR. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips.
Actieve vergelijker: Conventional ESD/EFTR
Patients will undergo standard ESD or EFTR without the use of dedicated traction devices. The endoscopist may use transparent cap assistance and positional changes for exposure, which is current standard practice.
Standard ESD or EFTR without the use of dedicated traction devices will be performed, then using the standard clips for closure.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Submucosal Dissection Efficiency
Tijdsspanne: 24 hours
The rate of submucosal dissection (measured in mm²/min), calculated from the start of submucosal entry to the completion of lesion removal.
24 hours

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Technical Success Rate of Purse-String Closure
Tijdsspanne: 24 hours
Percentage of cases where complete, circumferential mucosal/full-thickness defect closure is achieved using the novel two-tooth clip without conversion to alternative closure devices.
24 hours
Defect Closure Time
Tijdsspanne: 24 hours
Time taken to achieve complete purse-string closure of the post-resection defect.
24 hours
Incidence of Intraoperative Adverse Events
Tijdsspanne: 3 days
  • Rates of immediate perforation (unintended) in both groups during the dissection phase
  • Rates of significant active bleeding requiring emergency hemostasis (aside from planned vessel coagulation) in both groups during the dissection phase
  • Rates of muscularis injury in both groups during the dissection phase
3 days
Post-procedural Outcomes
Tijdsspanne: 3 months
  • Rates of delayed bleeding within 90 days
  • Rates of delayed perforation within 90 days
  • Rates of post-polypectomy electrocoagulation syndrome within 90 days
3 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Yan Liu, M.D.,Ph.D., Beijing 302 Hospital

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

24 april 2026

Primaire voltooiing (Geschat)

24 april 2027

Studie voltooiing (Geschat)

1 juli 2027

Studieregistratiedata

Eerst ingediend

6 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

6 mei 2026

Eerst geplaatst (Werkelijk)

12 mei 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

22 mei 2026

Laatste update ingediend die voldeed aan QC-criteria

20 mei 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren