A Novel Two-Tooth Clip for ESD and EFTR of GIST

Efficacy and Safety of a Novel Two-Tooth Clip-Assisted ESD and EFTR of GIST: A Single-Center, Prospective, Open-Label, Randomized Controlled Study

This study is designed to evaluate the efficacy and safety of a novel two-tooth endoscopic clip, utilized in a "clip with line" traction configuration, during endoscopic resection procedures (ESD and EFTR) of GIST. The novel clip's dual-tooth design is intended to provide a more secure anchor on the lesion, enabling effective counter-traction when combined with a line. The primary aim is to determine if this method improves submucosal dissection efficiency compared to conventional ESD. A secondary aim is to evaluate the performance of the same clip system for full-thickness or mucosal defect closure.

Descripción general del estudio

Descripción detallada

Endoscopic Submucosal Dissection (ESD) and Endoscopic Full-Thickness Resection (EFTR) are established, minimally invasive techniques for the en-bloc resection of gastrointestinal stromal tumor (GIST). However, a persistent challenge, especially in difficult locations or large lesions, is the lack of sufficient counter-traction, which leads to prolonged procedure times, increased risk of intraoperative bleeding, and potential for incomplete resection due to poor visualization of the submucosal layer. Furthermore, managing large post resection defects or perforations requires reliable and technically feasible endoscopic suturing.

This study introduces a novel two-tooth clip. The device's geometry is hypothesized to provide a stronger, more stable grasp on the targeted tissue compared to standard single-tooth or non-toothed clips. The study will investigate two sequential applications of this clip within a single procedure:

The Traction Phase: A "clip with line" technique will be employed. The novel two-tooth clip will be anchored to the proximal edge of the lesion. A dental line, pre-tied to the clip, will be used by the endoscopist to apply adjustable counter-traction. This is intended to lift the lesion, tauten the submucosal fibers, and clearly expose the dissection plane, thereby simulating the principle of surgical counter-traction.

The Closure Phase: Following lesion resection, the novel two-tooth clip will be utilized to perform a continuous, circumferential closure of the mucosal defect or perforation. The study will assess the technical success rate, time required for complete closure, and the clip's ability to securely approximate tissue layers.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

60

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Yan Liu, M.D., Ph.D.
  • Número de teléfono: +86-010-66947473
  • Correo electrónico: 13911798288@163.com

Copia de seguridad de contactos de estudio

  • Nombre: Min Min, M.D., Ph.D.
  • Número de teléfono: +86-010-66947473
  • Correo electrónico: minmin823@sina.com

Ubicaciones de estudio

      • Beijing, Porcelana, 100071
        • Reclutamiento
        • The Fifth Medical Center of Chinese PLA General Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • Age ≥ 18 and ≤ 85 years.
  • Patients diagnosed with gastric gastrointestinal lesions clinically indicated for ESD or EFTR.
  • Lesion size between 2 cm and 5 cm in diameter.
  • Willing and able to provide written informed consent.

Exclusion Criteria:

  • Lesions with clear evidence of deep submucosal invasion or distant metastasis precluding curative endoscopic resection.
  • Severe coagulation dysfunction (international normalized ratio >2.0, platelet count <50,000/µL) or ongoing use of dual antiplatelet therapy/anticoagulants that cannot be appropriately bridged or discontinued per guidelines.
  • Severe organ failure (cardiac, renal, hepatic, or respiratory) rendering the patient unsuitable for prolonged sedation or general anesthesia.
  • Pregnancy or lactation.
  • Prior surgical or endoscopic intervention at the target lesion site that results in significant fibrosis.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Novel Clip-Assisted Traction ESD/EFTR
Patients will undergo ESD or EFTR using the "clip with line" traction method with the novel two-tooth clip. After initial circumferential mucosal incision, the two-tooth clip (with pre-tied line) will be anchored to the lesion. The endoscopist will apply continuous or intermittent traction via the line to optimize the submucosal view. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips in a purse-string configuration.
"Clip with line" traction method with the novel two-tooth clip will be applied in patients undergoing ESD or EFTR. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips.
Comparador activo: Conventional ESD/EFTR
Patients will undergo standard ESD or EFTR without the use of dedicated traction devices. The endoscopist may use transparent cap assistance and positional changes for exposure, which is current standard practice.
Standard ESD or EFTR without the use of dedicated traction devices will be performed, then using the standard clips for closure.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Submucosal Dissection Efficiency
Periodo de tiempo: 24 hours
The rate of submucosal dissection (measured in mm²/min), calculated from the start of submucosal entry to the completion of lesion removal.
24 hours

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Technical Success Rate of Purse-String Closure
Periodo de tiempo: 24 hours
Percentage of cases where complete, circumferential mucosal/full-thickness defect closure is achieved using the novel two-tooth clip without conversion to alternative closure devices.
24 hours
Defect Closure Time
Periodo de tiempo: 24 hours
Time taken to achieve complete purse-string closure of the post-resection defect.
24 hours
Incidence of Intraoperative Adverse Events
Periodo de tiempo: 3 days
  • Rates of immediate perforation (unintended) in both groups during the dissection phase
  • Rates of significant active bleeding requiring emergency hemostasis (aside from planned vessel coagulation) in both groups during the dissection phase
  • Rates of muscularis injury in both groups during the dissection phase
3 days
Post-procedural Outcomes
Periodo de tiempo: 3 months
  • Rates of delayed bleeding within 90 days
  • Rates of delayed perforation within 90 days
  • Rates of post-polypectomy electrocoagulation syndrome within 90 days
3 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Yan Liu, M.D.,Ph.D., Beijing 302 Hospital

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

24 de abril de 2026

Finalización primaria (Estimado)

24 de abril de 2027

Finalización del estudio (Estimado)

1 de julio de 2027

Fechas de registro del estudio

Enviado por primera vez

6 de mayo de 2026

Primero enviado que cumplió con los criterios de control de calidad

6 de mayo de 2026

Publicado por primera vez (Actual)

12 de mayo de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

22 de mayo de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

20 de mayo de 2026

Última verificación

1 de mayo de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .