Validity and Reliability of a Mixed Reality-Based 6-Minute Walk Test
Validity and Reliability of a Mixed Reality-Based Adaptation of the 6-Minute Walk Test in Asymptomatic Adults
The 6-Minute Walk Test (6MWT) is a widely used field test for assessing functional exercise capacity, walking endurance, and submaximal performance related to activities of daily living. However, in conventional applications, environmental conditions, observer-related differences, and standardization issues may lead to variability in measurement outcomes. In addition, evaluating only the total walking distance may not adequately reflect clinically important changes such as performance decline and walking-related motor fatigue occurring during the test.
For this reason, recent studies have recommended analyzing 6MWT data by dividing the test into minute-by-minute segments and using performance change metrics such as the Distance Walked Index (DWI). These approaches allow a more detailed evaluation of changes in walking performance throughout the test duration.
With advances in measurement technologies, mixed reality (MR)-based applications have attracted attention as a means of enabling more objective, standardized, and reproducible implementation of conventional clinical tests. MR technology allows users to maintain interaction with the real environment while receiving digital guidance and feedback, thereby providing a safe and standardized assessment setting. Nevertheless, evidence regarding the validity and reliability of mixed reality-based adaptations of the 6MWT, particularly in asymptomatic adults, remains limited.
The aim of this study is to evaluate the criterion validity and test-retest reliability of a mixed reality-based 6-Minute Walk Test (MR-6MWT) developed using the Meta Quest 3 and Unity platform. In addition, convergent validity will be examined by analyzing the relationships between total walking distance, minute-by-minute performance changes, fatigue effect (%), and outcomes of the 4-Meter Walk Test, Timed Up and Go Test, and knee extensor muscle strength.
The findings of this study are expected to contribute to the development of a more objective, standardized, and digitally based mixed reality adaptation of the 6MWT. Furthermore, the results may provide a scientific foundation for future remote assessment and digital monitoring applications.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: Mehmet K ALTUNOK, PHD(c) in PT
- Numéro de téléphone: +90 5558175133
- E-mail: mehmetkaan.altunok@selcuk.edu.tr
Lieux d'étude
-
-
Selcuklu
-
Konya, Selcuklu, Turquie (Türkiye), 42130
- Recrutement
- Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation
-
Contact:
- Mehmet K ALTUNOK, PHD(c) in PT
- Numéro de téléphone: +90 5558175133
- E-mail: mehmetkaan.altunok@selcuk.edu.tr
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Aged between 18 and 65 years,
- Asymptomatic, with no known or active cardiopulmonary, neurological, or musculoskeletal disease-related symptoms,
- Ability to ambulate independently without the use of an assistive device,
- Visual, auditory, and vestibular functions sufficient to tolerate mixed reality applications,
- Cognitive ability sufficient to understand and follow test instructions,
- Ability to read, understand, and follow instructions in Turkish,
- Willingness to participate voluntarily in the study and provision of written informed consent.
Exclusion Criteria:
- Inability to safely complete walking tests due to serious musculoskeletal conditions (e.g., recent fracture, severe arthritis, advanced osteoarthritis, significant muscle or tendon injury),
- Presence of severe cardiopulmonary disease or any medical condition that may pose a risk during exercise testing (e.g., uncontrolled hypertension, heart failure, severe arrhythmia history, chronic obstructive pulmonary disease),
- High risk of balance loss or spatial disorientation in the mixed reality environment due to vestibular, visual, or auditory impairments,
- History of epilepsy or neurological conditions contraindicating mixed reality or head-mounted device use,
- Severe migraine, significant motion sickness history, or high risk of dizziness/nausea during mixed reality applications,
- Cognitive impairment or severe psychiatric conditions preventing understanding or completion of test procedures,
- Insufficient motivation or cooperation that may interfere with safe participation in the study.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Asymptomatic Adults
Asymptomatic adults aged 18-65 years undergoing conventional and mixed reality-based 6-Minute Walk Test assessments to evaluate criterion validity, test-retest reliability, fatigue-related performance changes, and associations with functional mobility and lower extremity muscle strength.
|
Participants will perform a mixed reality-based adaptation of the 6-Minute Walk Test (MR-6MWT) developed using the Meta Quest 3 headset and Unity platform.
The mixed reality environment provides standardized visual guidance and virtual markers while allowing participants to safely walk in the real environment.
During both conventional and MR-based assessments, walking distance, physiological responses, perceived exertion, and fatigue-related performance changes will be recorded.
The MR-6MWT will be repeated one week later to evaluate test-retest reliability and compared with the conventional 6-Minute Walk Test to assess criterion validity.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
6-Minute Walk Distance - Mixed Reality (MR-6MWT)
Délai: Baseline and 1-week follow-up
|
Walking distance during the mixed reality-based 6-Minute Walk Test (MR-6MWT) will be measured in meters to assess functional exercise capacity and walking endurance.
Criterion validity will be evaluated by comparison with the conventional 6-Minute Walk Test, and test-retest reliability will be assessed using repeated measurements performed one week apart.
|
Baseline and 1-week follow-up
|
|
Fatigue Effect During the Mixed Reality-Based 6-Minute Walk Test
Délai: Baseline and 1-week follow-up
|
Fatigue effect (%) during the MR-6MWT will be calculated using the percentage change between walking speeds measured during the first minute (0-1 min) and the last minute (5-6 min) of the test.
Higher values indicate greater performance decline during walking.
Validity and reliability will be evaluated through repeated assessments and comparison with the conventional 6-Minute Walk Test.
|
Baseline and 1-week follow-up
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
6-Minute Walk Distance - Conventional 6-Minute Walk Test
Délai: Baseline
|
Walking distance measured during the conventional 6-Minute Walk Test will be used as a reference measure for criterion validity analyses.
Greater walking distance indicates better functional exercise capacity.
|
Baseline
|
|
Fatigue Effect During the Conventional 6-Minute Walk Test
Délai: Baseline
|
Fatigue effect (%) during the conventional 6-Minute Walk Test will be calculated from the percentage change in walking speed between the first and last minutes of the test.
Higher values indicate greater walking-related performance decline.
|
Baseline
|
|
Timed Up and Go Test (TUG)
Délai: Baseline
|
Functional mobility will be assessed using the Timed Up and Go test.
Test completion time will be recorded in seconds, with shorter times indicating better functional mobility.
TUG outcomes will be analyzed for convergent validity with MR-6MWT parameters.
|
Baseline
|
|
4-Meter Walk Test (4MWT)
Délai: Baseline
|
Walking speed will be assessed using the 4-Meter Walk Test.
Walking speed will be calculated in meters per second (m/s), with higher values indicating better walking performance.
Results will be analyzed for convergent validity with MR-6MWT outcomes.
|
Baseline
|
|
Knee Extensor Muscle Strength
Délai: Baseline
|
Knee extensor muscle strength will be measured using a handheld digital dynamometer.
Maximum voluntary contraction values will be recorded, with higher values indicating greater muscle strength.
Outcomes will be analyzed for convergent validity with MR-6MWT parameters.
|
Baseline
|
|
Participant Satisfaction
Délai: Baseline
|
Participant satisfaction with conventional and mixed reality-based assessments will be evaluated using a 10-point visual analog scale ranging from 1 to 10, with higher scores indicating greater satisfaction.
|
Baseline
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chaise d'étude: Gülşah ÖZSOY, Assist. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
- Chaise d'étude: Zehra KORKUT, Assist. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
- Chaise d'étude: İsmail ÖZSOY, Assoc. Prof. Dr., Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
- Chaise d'étude: Mehmet A GÜLER, PhD, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
- Chaise d'étude: Yasemin GEDİKLİ ERTÜRK, MSc. in PT, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
- Chaise d'étude: Murat T İNANÇ, Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Konya, Türkiye
- Chaise d'étude: İhsan KODAK, Assist. Prof. Dr., Kırşehir Ahi Evran University, School of Physical Therapy and Rehabilitation, Kırşehir, Türkiye
Publications et liens utiles
Publications générales
- Christopher A, Kraft E, Olenick H, Kiesling R, Doty A. The reliability and validity of the Timed Up and Go as a clinical tool in individuals with and without disabilities across a lifespan: a systematic review. Disabil Rehabil. 2021 Jun;43(13):1799-1813. doi: 10.1080/09638288.2019.1682066. Epub 2019 Oct 26.
- Leone C, Severijns D, Dolezalova V, Baert I, Dalgas U, Romberg A, Bethoux F, Gebara B, Santoyo Medina C, Maamagi H, Rasova K, Maertens de Noordhout B, Knuts K, Skjerbaek A, Jensen E, Wagner JM, Feys P. Prevalence of Walking-Related Motor Fatigue in Persons With Multiple Sclerosis: Decline in Walking Distance Induced by the 6-Minute Walk Test. Neurorehabil Neural Repair. 2016 May;30(4):373-83. doi: 10.1177/1545968315597070. Epub 2015 Jul 27.
- ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002 Jul 1;166(1):111-7. doi: 10.1164/ajrccm.166.1.at1102. No abstract available.
- Hwang R, Morris NR, Mandrusiak A, Mudge A, Suna J, Adsett J, Russell T. Timed Up and Go Test: A Reliable and Valid Test in Patients With Chronic Heart Failure. J Card Fail. 2016 Aug;22(8):646-50. doi: 10.1016/j.cardfail.2015.09.018. Epub 2015 Oct 9.
- Van Geel F, Veldkamp R, Severijns D, Dalgas U, Feys P. Day-to-day reliability, agreement and discriminative validity of measuring walking-related performance fatigability in persons with multiple sclerosis. Mult Scler. 2020 Nov;26(13):1785-1789. doi: 10.1177/1352458519872465. Epub 2019 Sep 9.
- Maden C, Gozacan Karabulut D, Bagci B. Validity and reliability of an immersive virtual reality adaptation of the 6-minute pegboard and ring test. Hand Surg Rehabil. 2025 Feb;44(1):101981. doi: 10.1016/j.hansur.2024.101981. Epub 2024 Oct 30.
- Bayram GA, Sahin GE, Yilmaz G, Tayboga UI, Celik AG, Yildirim Y, Saribas PK, Tarakci D. Integration of the wingate anaerobic test into a virtual reality- based evaluation system. BMC Sports Sci Med Rehabil. 2025 Jul 2;17(1):163. doi: 10.1186/s13102-025-01220-4.
- Ramari C, Hvid LG, David AC, Dalgas U. The importance of lower-extremity muscle strength for lower-limb functional capacity in multiple sclerosis: Systematic review. Ann Phys Rehabil Med. 2020 Mar;63(2):123-137. doi: 10.1016/j.rehab.2019.11.005. Epub 2019 Dec 6.
- Grimpampi E, Oesen S, Halper B, Hofmann M, Wessner B, Mazza C. Reliability of gait variability assessment in older individuals during a six-minute walk test. J Biomech. 2015 Nov 26;48(15):4185-4189. doi: 10.1016/j.jbiomech.2015.10.008. Epub 2015 Oct 20.
- Gautschi OP, Smoll NR, Corniola MV, Joswig H, Chau I, Hildebrandt G, Schaller K, Stienen MN. Validity and Reliability of a Measurement of Objective Functional Impairment in Lumbar Degenerative Disc Disease: The Timed Up and Go (TUG) Test. Neurosurgery. 2016 Aug;79(2):270-8. doi: 10.1227/NEU.0000000000001195.
- Bohannon RW, Wang YC. Four-Meter Gait Speed: Normative Values and Reliability Determined for Adults Participating in the NIH Toolbox Study. Arch Phys Med Rehabil. 2019 Mar;100(3):509-513. doi: 10.1016/j.apmr.2018.06.031. Epub 2018 Aug 6.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- SelcukU_PT_6MWT_MR_ADAPTATION
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .