- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07605624
Active Post-Market Surveillance of Innovative Devices for Valvular Heart Disease
An Active Post-Market Surveillance Study Assessing the Real-World Clinical Applicability, Long-Term Safety, and Effectiveness of Innovative Medical Devices for Valvular Heart Disease
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: Guangyuan Song, MD, PhD
- Numéro de téléphone: +86 13801120805
- E-mail: songgy_anzhen@vip.163.com
Lieux d'étude
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Chine, 100029
- Beijing Anzhen Hospital
-
Contact:
- Guangyuan Song, MD, PhD
- Numéro de téléphone: +86 13801120805
- E-mail: songgy_anzhen@vip.163.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Patients with valvular heart disease (VHD) receiving treatment with prosthetic aortic valve replacement systems (transcatheter and surgical valves), transcatheter mitral valve edge-to-edge repair (TEER) systems, or transcatheter tricuspid valve annuloplasty systems
- Age ≥ 18 years
- Patients who voluntarily participate in the study and sign the informed consent form
- Willing and able to comply with follow-up requirements
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Transcatheter Aortic Valve Replacement
|
Transcatheter Aortic Valve Replacement
|
|
Transcatheter Edge-to-Edge Repair
|
Transcatheter Edge-to-Edge Repair
|
|
Transcatheter Tricuspid Valve Annuloplasty
|
Transcatheter Tricuspid Valve Annuloplasty
|
|
Device: Surgical Aortic Valve Replacement
|
Surgical Aortic Valve Replacement
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Mortality
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Rate of neurologic events
Délai: Up to 1 year post-procedure
|
Neurologic events are defined according to VARC-3 criteria, including ischaemic stroke, haemorrhagic stroke, and Transient ischaemic attack (TIA): Ischaemic Stroke: Acute focal neurologic deficit in a vascular territory with symptoms ≥ 24h OR < 24h with neuroimaging (CT or MRI) or pathology confirmation of CNS infarction. Haemorrhagic Stroke: Acute neurologic deficit due to non-traumatic intracranial hemorrhage, confirmed by neuroimaging (CT or MRI) or pathology. TIA: Transient focal neurologic deficit < 24h presumed to be ischaemic, but without evidence of acute infarction on neuroimaging (CT or MRI) or pathology. |
Up to 1 year post-procedure
|
|
Hospitalization
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Bleeding and transfusions
Délai: Up to 1 year post-procedure
|
Bleeding events are defined according to VARC-3 criteria: Type 1 (Minor): Overt bleeding that does not require intervention but leads to hospitalization, increased level of care, or medical evaluation, or requires a transfusion of 1 unit of whole blood or red blood cells. Type 2 (Major): Overt bleeding that requires a transfusion of 2 to 4 units of whole blood or red blood cells, or is associated with a hemoglobin drop of 3 to 5 g/dL. Type 3 (Life-threatening or Disabling): Overt bleeding in a critical organ (e.g., intracranial, pericardial with tamponade), causing hypovolemic shock or severe hypotension requiring vasopressors or surgery, or requiring a transfusion of ≥ 5 units of whole blood or red blood cells, or associated with a hemoglobin drop ≥ 5 g/dL. Type 4 (Fatal): Overt bleeding leading to death, classified as probable based on clinical suspicion or definite if confirmed by autopsy or neuroimaging. |
Up to 1 year post-procedure
|
|
Vascular and access-related complications
Délai: Periprocedural
|
Periprocedural
|
|
|
Cardiac structural complications
Délai: Periprocedural
|
Periprocedural
|
|
|
Bioprosthetic valve dysfunction
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Clinically significant valve thrombosis
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Technical success
Délai: Periprocedural
|
Technical success is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
Periprocedural
|
|
Device success
Délai: at 30 days
|
Device success is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
at 30 days
|
|
Early safety
Délai: at 30 days
|
Taking the Transcatheter Aortic Valve Replacement cohort as an example, early safety is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
at 30 days
|
|
Clinical efficacy
Délai: Up to 1 year post-procedure
|
Taking the Transcatheter Aortic Valve Replacement cohort as an example, clinical efficacy is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
Up to 1 year post-procedure
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Other procedural or valve-related complications
Délai: Periprocedural
|
Periprocedural
|
|
|
New conduction disturbances and arrhythmias
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Acute kidney injury
Délai: Periprocedural
|
Periprocedural
|
|
|
Myocardial infarction
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Leaflet thickening and reduced motion
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Change in Kansas City Cardiomyopathy Questionnaire (KCCQ) Score
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
New York Heart Association (NYHA) Functional Classification
Délai: Up to 1 year post-procedure
|
Class I, II, III, or IV
|
Up to 1 year post-procedure
|
|
EuroQol 5-Dimension (EQ-5D) Questionnaire Score
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Change in 6-Minute Walk Distance (6MWD)
Délai: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Maladie de la valve aortique
- Maladies cardiovasculaires
- Maladies cardiaques
- Maladies des valves cardiaques
- Obstruction de la sortie ventriculaire
- Sténose valvulaire aortique
- Insuffisance de la valve tricuspide
- Insuffisance de la valve mitrale
- Insuffisance valvulaire aortique
- Procédures chirurgicales, opératoires
- Procédures chirurgicales cardiovasculaires
- Procédures chirurgicales cardiaques
- Procédures chirurgicales thoraciques
- Implantation de prothèse
- Implantation de prothèse de valve cardiaque
- Remplacement de la valve aortique transcathéter
Autres numéros d'identification d'étude
- Beijinganzhen20260406
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .