- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07605624
Active Post-Market Surveillance of Innovative Devices for Valvular Heart Disease
An Active Post-Market Surveillance Study Assessing the Real-World Clinical Applicability, Long-Term Safety, and Effectiveness of Innovative Medical Devices for Valvular Heart Disease
Visão geral do estudo
Status
Descrição detalhada
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Contato de estudo
- Nome: Guangyuan Song, MD, PhD
- Número de telefone: +86 13801120805
- E-mail: songgy_anzhen@vip.163.com
Locais de estudo
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, China, 100029
- Beijing Anzhen Hospital
-
Contato:
- Guangyuan Song, MD, PhD
- Número de telefone: +86 13801120805
- E-mail: songgy_anzhen@vip.163.com
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Patients with valvular heart disease (VHD) receiving treatment with prosthetic aortic valve replacement systems (transcatheter and surgical valves), transcatheter mitral valve edge-to-edge repair (TEER) systems, or transcatheter tricuspid valve annuloplasty systems
- Age ≥ 18 years
- Patients who voluntarily participate in the study and sign the informed consent form
- Willing and able to comply with follow-up requirements
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
Transcatheter Aortic Valve Replacement
|
Transcatheter Aortic Valve Replacement
|
|
Transcatheter Edge-to-Edge Repair
|
Transcatheter Edge-to-Edge Repair
|
|
Transcatheter Tricuspid Valve Annuloplasty
|
Transcatheter Tricuspid Valve Annuloplasty
|
|
Device: Surgical Aortic Valve Replacement
|
Surgical Aortic Valve Replacement
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Mortality
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Rate of neurologic events
Prazo: Up to 1 year post-procedure
|
Neurologic events are defined according to VARC-3 criteria, including ischaemic stroke, haemorrhagic stroke, and Transient ischaemic attack (TIA): Ischaemic Stroke: Acute focal neurologic deficit in a vascular territory with symptoms ≥ 24h OR < 24h with neuroimaging (CT or MRI) or pathology confirmation of CNS infarction. Haemorrhagic Stroke: Acute neurologic deficit due to non-traumatic intracranial hemorrhage, confirmed by neuroimaging (CT or MRI) or pathology. TIA: Transient focal neurologic deficit < 24h presumed to be ischaemic, but without evidence of acute infarction on neuroimaging (CT or MRI) or pathology. |
Up to 1 year post-procedure
|
|
Hospitalization
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Bleeding and transfusions
Prazo: Up to 1 year post-procedure
|
Bleeding events are defined according to VARC-3 criteria: Type 1 (Minor): Overt bleeding that does not require intervention but leads to hospitalization, increased level of care, or medical evaluation, or requires a transfusion of 1 unit of whole blood or red blood cells. Type 2 (Major): Overt bleeding that requires a transfusion of 2 to 4 units of whole blood or red blood cells, or is associated with a hemoglobin drop of 3 to 5 g/dL. Type 3 (Life-threatening or Disabling): Overt bleeding in a critical organ (e.g., intracranial, pericardial with tamponade), causing hypovolemic shock or severe hypotension requiring vasopressors or surgery, or requiring a transfusion of ≥ 5 units of whole blood or red blood cells, or associated with a hemoglobin drop ≥ 5 g/dL. Type 4 (Fatal): Overt bleeding leading to death, classified as probable based on clinical suspicion or definite if confirmed by autopsy or neuroimaging. |
Up to 1 year post-procedure
|
|
Vascular and access-related complications
Prazo: Periprocedural
|
Periprocedural
|
|
|
Cardiac structural complications
Prazo: Periprocedural
|
Periprocedural
|
|
|
Bioprosthetic valve dysfunction
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Clinically significant valve thrombosis
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Technical success
Prazo: Periprocedural
|
Technical success is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
Periprocedural
|
|
Device success
Prazo: at 30 days
|
Device success is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
at 30 days
|
|
Early safety
Prazo: at 30 days
|
Taking the Transcatheter Aortic Valve Replacement cohort as an example, early safety is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
at 30 days
|
|
Clinical efficacy
Prazo: Up to 1 year post-procedure
|
Taking the Transcatheter Aortic Valve Replacement cohort as an example, clinical efficacy is defined according to VARC-3 criteria, requiring the fulfillment of the following:
|
Up to 1 year post-procedure
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Other procedural or valve-related complications
Prazo: Periprocedural
|
Periprocedural
|
|
|
New conduction disturbances and arrhythmias
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Acute kidney injury
Prazo: Periprocedural
|
Periprocedural
|
|
|
Myocardial infarction
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Leaflet thickening and reduced motion
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Change in Kansas City Cardiomyopathy Questionnaire (KCCQ) Score
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
New York Heart Association (NYHA) Functional Classification
Prazo: Up to 1 year post-procedure
|
Class I, II, III, or IV
|
Up to 1 year post-procedure
|
|
EuroQol 5-Dimension (EQ-5D) Questionnaire Score
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
|
|
Change in 6-Minute Walk Distance (6MWD)
Prazo: Up to 1 year post-procedure
|
Up to 1 year post-procedure
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
- Doença da Valva Aórtica
- Doenças cardiovasculares
- Doenças cardíacas
- Doenças das válvulas cardíacas
- Obstrução do Fluxo Ventricular
- Estenose da Válvula Aórtica
- Insuficiência da Válvula Tricúspide
- Insuficiência da Valva Mitral
- Insuficiência da Válvula Aórtica
- Procedimentos cirúrgicos, operatórios
- Procedimentos cirúrgicos cardiovasculares
- Procedimentos cirúrgicos cardíacos
- Procedimentos cirúrgicos torácicos
- Implante de prótese
- Implante de prótese da válvula cardíaca
- Substituição da válvula aórtica transcateter
Outros números de identificação do estudo
- Beijinganzhen20260406
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .