tSCS and AR Training on QoL and Physical Activity in Diabetic Neuropathy Patients
Combined Effects of Transcutaneous Spinal Cord Stimulation (tSCS) and Augmented Reality (AR) Training on Quality of Life (QoL) and Physical Activity in Diabetic Neuropathy Patients
Existing evidence of tSCS emphasizes pain relief and overlooks other functional parameters such as sensory enhancement, lower limb flexibility, and sustained improvements in physical activity and QoL.
Combined effects of tSCS and AR training on lower limb flexibility, vibration sense, QoL, and physical activity in patients with diabetic neuropathy. This dual approach has the potential to deliver a comprehensive strategy for managing DPN, which is low-cost, safe, and a more accessible solution for diabetic patients in Pakistan and around the world.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Pakistan has seen a rise in diabetes prevalence, 26.7% among adults, with 43.16% developing neuropathy. This high prevalence is associated with significant complications. Approximately 15% of these cases can progress to limb amputation, which severely impacts QoL, increases dependence on caregivers, and imposes long-term psychosocial and economic stress on patients and their families.
Transcutaneous spinal cord stimulation (tSCS) is a noninvasive neuromodulation technique that involves the application of electrical stimuli over the thoracic or lumbar spinal cord regions. Studies suggest that tSCS may influence afferent sensory pathways, potentially improving vibration perception and proprioceptive feedback, particularly at 30Hz, resulting in enhanced QoL.
Augmented reality (AR)-based rehabilitation has also emerged as a non-invasive tool to enhance balance, postural control, and motor learning in patients with diabetic neuropathy. Recent studies support the use of immersive AR environments in improving lower limb flexibility, gait, and functional performance in neuropathy patients, thus increasing their QoL.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Mirza Obaid Baig, MSPT
- Numéro de téléphone: 00923332238706
- E-mail: obaid.baig@riphah.edu.pk
Sauvegarde des contacts de l'étude
- Nom: Fatima Zahra, DPT
- Numéro de téléphone: 0092 333 4133592
- E-mail: fatimazahra905@gmail.com
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- More than or equals to 4 scores on Douleur Neuropathique 4 Questionnaire (DN4)
- More than or equals to 6 Hz at Neurothesiometer
Exclusion Criteria:
- Cognitively compromised (MOCA score ≤ 26/30)
- Metallic implants at skull
- Shunting
- Skin allergy
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: Transcutaneous spinal cord stimulation Group
|
Transcutaneous spinal cord stimulation will be administered non-invasively using surface electrodes placed over the D12-L1 spinal segment.
Stimulation will be delivered using the Soterix 1×1 Transcutaneous Electrical Stimulation (TES) unit.
Stimulation will be applied at a frequency range of 30 Hz.
The pulse duration is 1 ms, and the intensity will be set at 2 mA.
A ramp-up and ramp-down time of 30 seconds will be used to enhance participant comfort during the start and end of each stimulation session, following standardized electrode placement and safety protocols.
The stimulation will be delivered in a comfortable sitting or lying position
|
|
Expérimental: Transcutaneous spinal cord stimulation + Augmented reality Group
|
Transcutaneous spinal cord stimulation will be administered non-invasively using surface electrodes placed over the D12-L1 spinal segment.
Stimulation will be delivered using the Soterix 1×1 Transcutaneous Electrical Stimulation (TES) unit.
Stimulation will be applied at a frequency range of 30 Hz.
The pulse duration is 1 ms, and the intensity will be set at 2 mA.
A ramp-up and ramp-down time of 30 seconds will be used to enhance participant comfort during the start and end of each stimulation session, following standardized electrode placement and safety protocols.
The stimulation will be delivered in a comfortable sitting or lying position
AR-based rehabilitation will involve interactive balance and coordination tasks performed in a virtual environment all while receiving real-time visual feedback to guide movement accuracy and postural control.
The main training block will comprise exercises focusing on hip flexion, hip abduction, knee flexion, and lateral weight shifting.
Each module will be performed for 5-8 minutes, with short rest intervals between tasks.
|
|
Comparateur actif: Augmented reality Group
|
AR-based rehabilitation will involve interactive balance and coordination tasks performed in a virtual environment all while receiving real-time visual feedback to guide movement accuracy and postural control.
The main training block will comprise exercises focusing on hip flexion, hip abduction, knee flexion, and lateral weight shifting.
Each module will be performed for 5-8 minutes, with short rest intervals between tasks.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
International Physical Activity Questionnaire
Délai: Up to week 5
|
The IPAQ assesses physical activity across four domains: work, transport, domestic, and recreation time. It includes 27 items and collects data on frequency and duration of physical activity at three intensity levels; high, moderate, and low. The IPAQ has Test-retest reliability ICC = 0.80. the score is calculated by converting activity into MET-minutes/week. Low activity: < 600 MET-min/week, Moderate activity: 600-3000 MET-min/week and High activity: > 3000 MET-min/week. Outcome will be measured at Baseline then Week 1 and then week 5 |
Up to week 5
|
|
Diabetes Quality of Life Questionnaire
Délai: Up to week 5
|
The Diabetes Quality of Life (D-QoL) questionnaire is a disease-specific instrument originally developed for the diabetes control and complications trial (DCCT) to assess the quality of life in individuals with diabetes mellitus.
It has 46 items divided into three main domains: satisfaction, impact, and worry.
Each item is rated on a likert scale, with higher scores indicating greater impact, or concern.
The tool assesses the individual's perception of how diabetes affects various aspects of life, including daily activities, social functioning, and emotional well-being.
The D-QoL has demonstrated strong reliability and validity, with internal consistency ranging from 0.73 to 0.94 for its subscales.
Outcome will be measured at Baseline then Week 1 and then week 5
|
Up to week 5
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Neurothesiometer
Délai: Up to week 5
|
The neurothesiometer is a non-invasive and reliable device for assessing vibration perception threshold (VPT).
The neurothesiometer demonstrated excellent intra-class correlation coefficients (ICCs) exceeding 0.90, highlighting its consistency.
The cut off value of ≥ 6hz indicates presence of neuropathy.
This tool is beneficial in clinical settings due to its ease of use, objective quantification, and ability to detect subclinical neuropathy.
The neurothesiometer offers superior standardization, making it a preferred method for evaluating protective sensation and vibration loss in diabetic populations.
Outcome will be measured at Baseline then Week 1 and then week 5
|
Up to week 5
|
|
Sit and reach test
Délai: Up to week 5
|
The sit-and-reach test is a widely used tool for assessing lower limb flexibility.
The test demonstrates excellent reliability, with intra-class correlation coefficients (ICCs) ranging from 0.92 to 0.99, indicating strong consistency in repeated measures.
Scoring is based on distances recorded in inches or centimeters, higher values indicate better flexibility.
It is simple to administer, cost-effective, making it a reliable method for flexibility assessment in healthy adult populations.
Outcome will be measured at Baseline then Week 1 and then week 5
|
Up to week 5
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Mirza Obaid Baig, MSPT, Riphah International University
Publications et liens utiles
Publications générales
- Barss TS, Parhizi B, Porter J, Mushahwar VK. Neural Substrates of Transcutaneous Spinal Cord Stimulation: Neuromodulation across Multiple Segments of the Spinal Cord. J Clin Med. 2022 Jan 27;11(3):639. doi: 10.3390/jcm11030639.
- Stanica IC, Moldoveanu F, Portelli GP, Dascalu MI, Moldoveanu A, Ristea MG. Flexible Virtual Reality System for Neurorehabilitation and Quality of Life Improvement. Sensors (Basel). 2020 Oct 23;20(21):6045. doi: 10.3390/s20216045.
- Mekhail NA, Argoff CE, Taylor RS, Nasr C, Caraway DL, Gliner BE, Subbaroyan J, Brooks ES. High-frequency spinal cord stimulation at 10 kHz for the treatment of painful diabetic neuropathy: design of a multicenter, randomized controlled trial (SENZA-PDN). Trials. 2020 Jan 15;21(1):87. doi: 10.1186/s13063-019-4007-y.
- Alonso-Enriquez L, Gomez-Cuaresma L, Billot M, Garcia-Bernal MI, Benitez-Lugo ML, Casuso-Holgado MJ, Luque-Moreno C. Effectiveness of Virtual Reality and Feedback to Improve Gait and Balance in Patients with Diabetic Peripheral Neuropathies: Systematic Review and Meta-Analysis. Healthcare (Basel). 2023 Nov 24;11(23):3037. doi: 10.3390/healthcare11233037.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- REC02260 Fatima Zahra
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .