Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

tSCS and AR Training on QoL and Physical Activity in Diabetic Neuropathy Patients

1 czerwca 2026 zaktualizowane przez: Riphah International University

Combined Effects of Transcutaneous Spinal Cord Stimulation (tSCS) and Augmented Reality (AR) Training on Quality of Life (QoL) and Physical Activity in Diabetic Neuropathy Patients

Existing evidence of tSCS emphasizes pain relief and overlooks other functional parameters such as sensory enhancement, lower limb flexibility, and sustained improvements in physical activity and QoL.

Combined effects of tSCS and AR training on lower limb flexibility, vibration sense, QoL, and physical activity in patients with diabetic neuropathy. This dual approach has the potential to deliver a comprehensive strategy for managing DPN, which is low-cost, safe, and a more accessible solution for diabetic patients in Pakistan and around the world.

Przegląd badań

Szczegółowy opis

Pakistan has seen a rise in diabetes prevalence, 26.7% among adults, with 43.16% developing neuropathy. This high prevalence is associated with significant complications. Approximately 15% of these cases can progress to limb amputation, which severely impacts QoL, increases dependence on caregivers, and imposes long-term psychosocial and economic stress on patients and their families.

Transcutaneous spinal cord stimulation (tSCS) is a noninvasive neuromodulation technique that involves the application of electrical stimuli over the thoracic or lumbar spinal cord regions. Studies suggest that tSCS may influence afferent sensory pathways, potentially improving vibration perception and proprioceptive feedback, particularly at 30Hz, resulting in enhanced QoL.

Augmented reality (AR)-based rehabilitation has also emerged as a non-invasive tool to enhance balance, postural control, and motor learning in patients with diabetic neuropathy. Recent studies support the use of immersive AR environments in improving lower limb flexibility, gait, and functional performance in neuropathy patients, thus increasing their QoL.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

36

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • More than or equals to 4 scores on Douleur Neuropathique 4 Questionnaire (DN4)
  • More than or equals to 6 Hz at Neurothesiometer

Exclusion Criteria:

  • Cognitively compromised (MOCA score ≤ 26/30)
  • Metallic implants at skull
  • Shunting
  • Skin allergy

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Transcutaneous spinal cord stimulation Group
Transcutaneous spinal cord stimulation will be administered non-invasively using surface electrodes placed over the D12-L1 spinal segment. Stimulation will be delivered using the Soterix 1×1 Transcutaneous Electrical Stimulation (TES) unit. Stimulation will be applied at a frequency range of 30 Hz. The pulse duration is 1 ms, and the intensity will be set at 2 mA. A ramp-up and ramp-down time of 30 seconds will be used to enhance participant comfort during the start and end of each stimulation session, following standardized electrode placement and safety protocols. The stimulation will be delivered in a comfortable sitting or lying position
Eksperymentalny: Transcutaneous spinal cord stimulation + Augmented reality Group
Transcutaneous spinal cord stimulation will be administered non-invasively using surface electrodes placed over the D12-L1 spinal segment. Stimulation will be delivered using the Soterix 1×1 Transcutaneous Electrical Stimulation (TES) unit. Stimulation will be applied at a frequency range of 30 Hz. The pulse duration is 1 ms, and the intensity will be set at 2 mA. A ramp-up and ramp-down time of 30 seconds will be used to enhance participant comfort during the start and end of each stimulation session, following standardized electrode placement and safety protocols. The stimulation will be delivered in a comfortable sitting or lying position
AR-based rehabilitation will involve interactive balance and coordination tasks performed in a virtual environment all while receiving real-time visual feedback to guide movement accuracy and postural control. The main training block will comprise exercises focusing on hip flexion, hip abduction, knee flexion, and lateral weight shifting. Each module will be performed for 5-8 minutes, with short rest intervals between tasks.
Aktywny komparator: Augmented reality Group
AR-based rehabilitation will involve interactive balance and coordination tasks performed in a virtual environment all while receiving real-time visual feedback to guide movement accuracy and postural control. The main training block will comprise exercises focusing on hip flexion, hip abduction, knee flexion, and lateral weight shifting. Each module will be performed for 5-8 minutes, with short rest intervals between tasks.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
International Physical Activity Questionnaire
Ramy czasowe: Up to week 5

The IPAQ assesses physical activity across four domains: work, transport, domestic, and recreation time. It includes 27 items and collects data on frequency and duration of physical activity at three intensity levels; high, moderate, and low. The IPAQ has Test-retest reliability ICC = 0.80. the score is calculated by converting activity into MET-minutes/week. Low activity: < 600 MET-min/week, Moderate activity: 600-3000 MET-min/week and High activity: > 3000 MET-min/week.

Outcome will be measured at Baseline then Week 1 and then week 5

Up to week 5
Diabetes Quality of Life Questionnaire
Ramy czasowe: Up to week 5
The Diabetes Quality of Life (D-QoL) questionnaire is a disease-specific instrument originally developed for the diabetes control and complications trial (DCCT) to assess the quality of life in individuals with diabetes mellitus. It has 46 items divided into three main domains: satisfaction, impact, and worry. Each item is rated on a likert scale, with higher scores indicating greater impact, or concern. The tool assesses the individual's perception of how diabetes affects various aspects of life, including daily activities, social functioning, and emotional well-being. The D-QoL has demonstrated strong reliability and validity, with internal consistency ranging from 0.73 to 0.94 for its subscales. Outcome will be measured at Baseline then Week 1 and then week 5
Up to week 5

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Neurothesiometer
Ramy czasowe: Up to week 5
The neurothesiometer is a non-invasive and reliable device for assessing vibration perception threshold (VPT). The neurothesiometer demonstrated excellent intra-class correlation coefficients (ICCs) exceeding 0.90, highlighting its consistency. The cut off value of ≥ 6hz indicates presence of neuropathy. This tool is beneficial in clinical settings due to its ease of use, objective quantification, and ability to detect subclinical neuropathy. The neurothesiometer offers superior standardization, making it a preferred method for evaluating protective sensation and vibration loss in diabetic populations. Outcome will be measured at Baseline then Week 1 and then week 5
Up to week 5
Sit and reach test
Ramy czasowe: Up to week 5
The sit-and-reach test is a widely used tool for assessing lower limb flexibility. The test demonstrates excellent reliability, with intra-class correlation coefficients (ICCs) ranging from 0.92 to 0.99, indicating strong consistency in repeated measures. Scoring is based on distances recorded in inches or centimeters, higher values indicate better flexibility. It is simple to administer, cost-effective, making it a reliable method for flexibility assessment in healthy adult populations. Outcome will be measured at Baseline then Week 1 and then week 5
Up to week 5

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Mirza Obaid Baig, MSPT, Riphah International University

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

15 czerwca 2026

Zakończenie podstawowe (Szacowany)

31 grudnia 2026

Ukończenie studiów (Szacowany)

31 stycznia 2027

Daty rejestracji na studia

Pierwszy przesłany

30 kwietnia 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

1 czerwca 2026

Pierwszy wysłany (Rzeczywisty)

2 czerwca 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

2 czerwca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

1 czerwca 2026

Ostatnia weryfikacja

1 czerwca 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj