Clinical Validation of AI-Based Quantitative Eye Movement Analysis From Smartphone 9-Gaze Videos (Glandy EOM) (GLANDY-EOM-VAL)

28 mai 2026 mis à jour par: THYROSCOPE INC.

Prospective Multicenter Observational Study for Clinical Validation of AI-Based Quantitative Eye Movement Analysis Using Smartphone-Recorded 9-Gaze Videos

This prospective, multicenter, multinational observational study evaluates the clinical validity of an AI-based quantitative eye movement analysis system (Glandy EOM) that analyzes smartphone-recorded 9-gaze videos. Approximately 200 adults per site with suspected or confirmed ocular motility abnormalities will undergo a single study visit consisting of a standard clinical 9-gaze examination, an assistant-aided smartphone video recording, and a patient self-recorded video acquisition using a mobile application. Because the study population is defined by clinical suspicion or diagnosis of ocular motility abnormality rather than confirmed disease at enrollment, some participants may be clinically judged to have no abnormality on formal evaluation; such subjects remain part of the study population and are not considered healthy volunteers. AI-derived quantitative eye movement metrics (corneal center displacement in millimeters and angular deviation) will be compared with rater-derived measurements obtained from the same videos using a calibrated reference approach, and with clinician-assessed 9-gaze grading. The investigational device is used solely for video acquisition and analysis and does not influence clinical decision-making.

Aperçu de l'étude

Description détaillée

Ocular motility is commonly evaluated using the 9-gaze examination, which relies on clinician observation and semi-quantitative grading. This approach is inherently subjective and can show inter-observer variability and limited sensitivity to subtle changes over time. Objective, quantitative assessment of eye movement remains an unmet clinical need, particularly for monitoring disease progression and treatment response.

Recent advances in artificial intelligence have enabled automated analysis of facial and ocular features from smartphone-recorded videos, offering the potential for reproducible quantitative measurement of eye movement. Glandy EOM is an investigational software-only medical device (SaMD) developed by THYROSCOPE INC. that processes smartphone-recorded 9-gaze videos to generate quantitative eye movement metrics. Glandy EOM has not yet received regulatory approval and is used for research purposes only in this study.

The study is a prospective, multicenter, multinational observational investigation designed to evaluate the clinical validity of Glandy EOM. The study population consists of adults with suspected or confirmed ocular motility abnormalities; healthy volunteers without any clinical indication for 9-gaze examination are not enrolled. Because eligibility is based on clinical suspicion or diagnosis of ocular motility abnormality rather than confirmed disease at enrollment, some participants may ultimately be clinically judged to have no abnormality on formal evaluation; such subjects remain part of the study population. Participants will undergo a single study visit consisting of (1) a standard clinical 9-gaze examination with clinician grading (-4 to +4), (2) a smartphone video recording performed with the assistance of a trained operator using a standardized setup, and (3) a patient self-recorded smartphone video acquired through the study mobile application.

For quantitative reference measurements, independent rater-derived measurements will be obtained from the recorded videos using a calibrated reference approach. A calibration marker of known size will be placed on the glabella during video acquisition to enable real-world scale estimation for the reference measurements. The calibration marker is used only for rater-based reference measurement and is not used by the AI algorithm.

The primary objective is to evaluate agreement between AI-derived quantitative eye movement metrics and rater-derived measurements of corneal center displacement, expressed as distance (mm) and angular deviation. Secondary objectives are to evaluate correlation between AI-derived metrics and clinician-assessed 9-gaze grading, and to evaluate whether AI-derived metrics obtained from patient self-recorded videos are comparable to those obtained from assistant-aided recordings. The investigational device is used solely for video acquisition and analysis and does not influence clinical decision-making during the study.

Type d'étude

Observationnel

Inscription (Estimé)

1000

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

    • California
      • San Jose, California, États-Unis, 95134

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Adults of legal age of consent with suspected or confirmed ocular motility abnormalities, recruited at participating ophthalmology sites.

Some enrolled participants may ultimately be clinically judged to have no abnormality on formal evaluation; these subjects remain part of the study population and are not considered healthy volunteers.

La description

Inclusion Criteria:

  • Adults who have reached the legal age of consent for research participation in the applicable jurisdiction.
  • Subjects with suspected or known ocular motility abnormalities.
  • Subjects who are able to understand and follow gaze instructions required for the 9-gaze examination, as judged by the investigator.
  • Subjects who are able to undergo facial video recording using a smartphone.
  • Subjects who provide written informed consent.

Exclusion Criteria:

  • Conditions that prevent reliable detection of ocular landmarks in video recordings (e.g., severe ptosis, corneal opacity, or significant occlusion of the eyes).
  • Ocular or facial conditions that, in the opinion of the investigator, may significantly interfere with image-based analysis.
  • Subjects who are unable to comply with study procedures.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Ocular motility abnormality cohort (single cohort)
Adults with suspected or confirmed ocular motility abnormalities scheduled for clinical 9-gaze examination at participating ophthalmology sites. No separate healthy-volunteer control cohort is enrolled; some participants may ultimately be clinically judged to have no abnormality on formal evaluation but remain part of the study population.

Glandy EOM is an investigational software-only medical device developed by THYROSCOPE INC. It has not yet received regulatory approval and is used for research purposes only in this study. Glandy EOM processes smartphone-recorded 9-gaze facial videos to generate AI-derived quantitative eye movement metrics:

  • Corneal center displacement (mm)
  • Angular deviation (degrees) Video acquisition in this study includes (a) an assistant-aided recording using a standardized smartphone setup in the clinical environment and (b) a patient self-recorded video acquired through the study mobile application. A calibration marker of known size placed on the glabella is used for rater-derived reference measurements only and is NOT used by the AI algorithm.

AI outputs are generated for research analysis and are NOT used to guide real-time clinical decisions during the study.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Agreement between AI-derived and rater-derived corneal center displacement (distance, mm)
Délai: At study visit (single visit)
Agreement between AI-derived and rater-derived measurements of corneal center displacement expressed as distance (mm) across 9 gaze positions, assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis.
At study visit (single visit)
Agreement between AI-derived and rater-derived angular deviation (degrees)
Délai: At study visit (single visit)
Agreement between AI-derived and rater-derived measurements of corneal center displacement expressed as angular deviation (degrees) across 9 gaze positions, assessed by ICC and Bland-Altman analysis.
At study visit (single visit)
Linear association and absolute error vs. rater-derived reference
Délai: At study visit (single visit)
Linear association and absolute error between AI-derived and rater-derived measurements (both distance and angular deviation), assessed by Pearson correlation coefficient and mean absolute error (MAE), respectively.
At study visit (single visit)

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Correlation between AI-derived metrics (assistant-aided recording) and clinician-assessed 9-gaze grading
Délai: At study visit (single visit)
Correlation between AI-derived eye movement metrics obtained from assistant-aided smartphone recordings and clinician-assessed 9-gaze grading (-4 to +4), assessed using Spearman correlation.
At study visit (single visit)
Correlation between AI-derived metrics (patient self-recorded) and clinician-assessed 9-gaze grading
Délai: At study visit (single visit)
Correlation between AI-derived eye movement metrics obtained from patient self-recorded smartphone videos and clinician-assessed 9-gaze grading (-4 to +4), assessed using Spearman correlation.
At study visit (single visit)
Agreement between AI-derived metrics from patient self-recorded vs. assistant-aided recordings
Délai: At study visit (single visit)
Agreement between AI-derived metrics obtained from patient self-recorded and assistant-aided smartphone videos, assessed using ICC and Bland-Altman analysis.
At study visit (single visit)
Linear association and absolute error: patient self-recorded vs. assistant-aided
Délai: At study visit (single visit)
Linear association and absolute error between AI-derived metrics from patient self-recorded and assistant-aided smartphone videos, assessed using Pearson correlation coefficient and mean absolute error (MAE).
At study visit (single visit)

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 juillet 2026

Achèvement primaire (Estimé)

30 juin 2027

Achèvement de l'étude (Estimé)

31 décembre 2027

Dates d'inscription aux études

Première soumission

18 avril 2026

Première soumission répondant aux critères de contrôle qualité

28 mai 2026

Première publication (Réel)

3 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

3 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

28 mai 2026

Dernière vérification

1 avril 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Description du régime IPD

The dataset includes patient-captured smartphone 9-gaze facial videos, which are inherently identifiable biometric data and carry a higher re-identification risk than static images. Public sharing of individual participant data (IPD) would therefore pose a substantial privacy risk that cannot be fully mitigated by standard de-identification of tabular variables alone. The informed consent obtained from participants and the IRB/EC-approved protocol do not authorize broad third-party sharing of these video recordings or associated individual-level records. As this is a multinational, multicenter study, the collected data are also subject to the personal data protection laws applicable in each participating jurisdiction, including the Republic of Korea's Personal Information Protection Act (PIPA), the EU General Data Protection Regulation (GDPR), and the US HIPAA where applicable, which restrict external transfer of identifiable health and biometric information. In addition, the investiga

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Oui

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .