Clinical Validation of AI-Based Quantitative Eye Movement Analysis From Smartphone 9-Gaze Videos (Glandy EOM) (GLANDY-EOM-VAL)

28 de maio de 2026 atualizado por: THYROSCOPE INC.

Prospective Multicenter Observational Study for Clinical Validation of AI-Based Quantitative Eye Movement Analysis Using Smartphone-Recorded 9-Gaze Videos

This prospective, multicenter, multinational observational study evaluates the clinical validity of an AI-based quantitative eye movement analysis system (Glandy EOM) that analyzes smartphone-recorded 9-gaze videos. Approximately 200 adults per site with suspected or confirmed ocular motility abnormalities will undergo a single study visit consisting of a standard clinical 9-gaze examination, an assistant-aided smartphone video recording, and a patient self-recorded video acquisition using a mobile application. Because the study population is defined by clinical suspicion or diagnosis of ocular motility abnormality rather than confirmed disease at enrollment, some participants may be clinically judged to have no abnormality on formal evaluation; such subjects remain part of the study population and are not considered healthy volunteers. AI-derived quantitative eye movement metrics (corneal center displacement in millimeters and angular deviation) will be compared with rater-derived measurements obtained from the same videos using a calibrated reference approach, and with clinician-assessed 9-gaze grading. The investigational device is used solely for video acquisition and analysis and does not influence clinical decision-making.

Visão geral do estudo

Descrição detalhada

Ocular motility is commonly evaluated using the 9-gaze examination, which relies on clinician observation and semi-quantitative grading. This approach is inherently subjective and can show inter-observer variability and limited sensitivity to subtle changes over time. Objective, quantitative assessment of eye movement remains an unmet clinical need, particularly for monitoring disease progression and treatment response.

Recent advances in artificial intelligence have enabled automated analysis of facial and ocular features from smartphone-recorded videos, offering the potential for reproducible quantitative measurement of eye movement. Glandy EOM is an investigational software-only medical device (SaMD) developed by THYROSCOPE INC. that processes smartphone-recorded 9-gaze videos to generate quantitative eye movement metrics. Glandy EOM has not yet received regulatory approval and is used for research purposes only in this study.

The study is a prospective, multicenter, multinational observational investigation designed to evaluate the clinical validity of Glandy EOM. The study population consists of adults with suspected or confirmed ocular motility abnormalities; healthy volunteers without any clinical indication for 9-gaze examination are not enrolled. Because eligibility is based on clinical suspicion or diagnosis of ocular motility abnormality rather than confirmed disease at enrollment, some participants may ultimately be clinically judged to have no abnormality on formal evaluation; such subjects remain part of the study population. Participants will undergo a single study visit consisting of (1) a standard clinical 9-gaze examination with clinician grading (-4 to +4), (2) a smartphone video recording performed with the assistance of a trained operator using a standardized setup, and (3) a patient self-recorded smartphone video acquired through the study mobile application.

For quantitative reference measurements, independent rater-derived measurements will be obtained from the recorded videos using a calibrated reference approach. A calibration marker of known size will be placed on the glabella during video acquisition to enable real-world scale estimation for the reference measurements. The calibration marker is used only for rater-based reference measurement and is not used by the AI algorithm.

The primary objective is to evaluate agreement between AI-derived quantitative eye movement metrics and rater-derived measurements of corneal center displacement, expressed as distance (mm) and angular deviation. Secondary objectives are to evaluate correlation between AI-derived metrics and clinician-assessed 9-gaze grading, and to evaluate whether AI-derived metrics obtained from patient self-recorded videos are comparable to those obtained from assistant-aided recordings. The investigational device is used solely for video acquisition and analysis and does not influence clinical decision-making during the study.

Tipo de estudo

Observacional

Inscrição (Estimado)

1000

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra Não Probabilística

População do estudo

Adults of legal age of consent with suspected or confirmed ocular motility abnormalities, recruited at participating ophthalmology sites.

Some enrolled participants may ultimately be clinically judged to have no abnormality on formal evaluation; these subjects remain part of the study population and are not considered healthy volunteers.

Descrição

Inclusion Criteria:

  • Adults who have reached the legal age of consent for research participation in the applicable jurisdiction.
  • Subjects with suspected or known ocular motility abnormalities.
  • Subjects who are able to understand and follow gaze instructions required for the 9-gaze examination, as judged by the investigator.
  • Subjects who are able to undergo facial video recording using a smartphone.
  • Subjects who provide written informed consent.

Exclusion Criteria:

  • Conditions that prevent reliable detection of ocular landmarks in video recordings (e.g., severe ptosis, corneal opacity, or significant occlusion of the eyes).
  • Ocular or facial conditions that, in the opinion of the investigator, may significantly interfere with image-based analysis.
  • Subjects who are unable to comply with study procedures.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Ocular motility abnormality cohort (single cohort)
Adults with suspected or confirmed ocular motility abnormalities scheduled for clinical 9-gaze examination at participating ophthalmology sites. No separate healthy-volunteer control cohort is enrolled; some participants may ultimately be clinically judged to have no abnormality on formal evaluation but remain part of the study population.

Glandy EOM is an investigational software-only medical device developed by THYROSCOPE INC. It has not yet received regulatory approval and is used for research purposes only in this study. Glandy EOM processes smartphone-recorded 9-gaze facial videos to generate AI-derived quantitative eye movement metrics:

  • Corneal center displacement (mm)
  • Angular deviation (degrees) Video acquisition in this study includes (a) an assistant-aided recording using a standardized smartphone setup in the clinical environment and (b) a patient self-recorded video acquired through the study mobile application. A calibration marker of known size placed on the glabella is used for rater-derived reference measurements only and is NOT used by the AI algorithm.

AI outputs are generated for research analysis and are NOT used to guide real-time clinical decisions during the study.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Agreement between AI-derived and rater-derived corneal center displacement (distance, mm)
Prazo: At study visit (single visit)
Agreement between AI-derived and rater-derived measurements of corneal center displacement expressed as distance (mm) across 9 gaze positions, assessed by intraclass correlation coefficient (ICC) and Bland-Altman analysis.
At study visit (single visit)
Agreement between AI-derived and rater-derived angular deviation (degrees)
Prazo: At study visit (single visit)
Agreement between AI-derived and rater-derived measurements of corneal center displacement expressed as angular deviation (degrees) across 9 gaze positions, assessed by ICC and Bland-Altman analysis.
At study visit (single visit)
Linear association and absolute error vs. rater-derived reference
Prazo: At study visit (single visit)
Linear association and absolute error between AI-derived and rater-derived measurements (both distance and angular deviation), assessed by Pearson correlation coefficient and mean absolute error (MAE), respectively.
At study visit (single visit)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Correlation between AI-derived metrics (assistant-aided recording) and clinician-assessed 9-gaze grading
Prazo: At study visit (single visit)
Correlation between AI-derived eye movement metrics obtained from assistant-aided smartphone recordings and clinician-assessed 9-gaze grading (-4 to +4), assessed using Spearman correlation.
At study visit (single visit)
Correlation between AI-derived metrics (patient self-recorded) and clinician-assessed 9-gaze grading
Prazo: At study visit (single visit)
Correlation between AI-derived eye movement metrics obtained from patient self-recorded smartphone videos and clinician-assessed 9-gaze grading (-4 to +4), assessed using Spearman correlation.
At study visit (single visit)
Agreement between AI-derived metrics from patient self-recorded vs. assistant-aided recordings
Prazo: At study visit (single visit)
Agreement between AI-derived metrics obtained from patient self-recorded and assistant-aided smartphone videos, assessed using ICC and Bland-Altman analysis.
At study visit (single visit)
Linear association and absolute error: patient self-recorded vs. assistant-aided
Prazo: At study visit (single visit)
Linear association and absolute error between AI-derived metrics from patient self-recorded and assistant-aided smartphone videos, assessed using Pearson correlation coefficient and mean absolute error (MAE).
At study visit (single visit)

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de julho de 2026

Conclusão Primária (Estimado)

30 de junho de 2027

Conclusão do estudo (Estimado)

31 de dezembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

18 de abril de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

28 de maio de 2026

Primeira postagem (Real)

3 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

3 de junho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

28 de maio de 2026

Última verificação

1 de abril de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

The dataset includes patient-captured smartphone 9-gaze facial videos, which are inherently identifiable biometric data and carry a higher re-identification risk than static images. Public sharing of individual participant data (IPD) would therefore pose a substantial privacy risk that cannot be fully mitigated by standard de-identification of tabular variables alone. The informed consent obtained from participants and the IRB/EC-approved protocol do not authorize broad third-party sharing of these video recordings or associated individual-level records. As this is a multinational, multicenter study, the collected data are also subject to the personal data protection laws applicable in each participating jurisdiction, including the Republic of Korea's Personal Information Protection Act (PIPA), the EU General Data Protection Regulation (GDPR), and the US HIPAA where applicable, which restrict external transfer of identifiable health and biometric information. In addition, the investiga

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .