- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07686211
Deformable Tissue Modelling and Augmented Reality Based Guidance for Head and Neck Tumor Re-Resection Task (SPeAR)
Head and neck cancers have one of the highest recurrence rates among solid malignancies, and recurrence is strongly correlated with overall survival. Reducing recurrence rates depends, in part, on the surgeon's ability to accurately re-resect areas of positive or close margins during surgery. Currently, margin status is communicated primarily through verbal descriptions between the surgeon and pathologist, which can be imprecise. This challenge is further compounded by the deformable nature of soft tissues, as once the specimen is resected, the shape and size of the specimen change, making it difficult to accurately map the specimen's margins back onto the surgical site.
Emerging technologies -such as augmented reality (AR), 3D scanning, and advanced soft tissue modeling- offer promising solutions for improving surgical navigation and precision. Building on these advances, an AR-based surgical navigation system was developed specifically for head and neck tumor resections. The system uses a 3D scanner to generate virtual models of both the resected specimen and the patient's surgical site, as demonstrated in prior work. A soft tissue modeling algorithm is then applied to account for specimen shrinkage and deformation, enabling accurate tracking of positive tumor margins. This guidance information is visualized through an AR headset, which overlays the margin data directly onto the patient's surgical site, providing surgeons with real-time visual guidance during re-resection.
In this study, the goal is to evaluate the benefits and usability of this novel navigation software, compared to the standard of care. By assessing surgeon performance and user experience in cadaveric tasks with and without the AR system to identify strengths, limitations, and opportunities for refinement of the system, ultimately advancing surgical precision and improving patient outcomes by reducing recurrence rates.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Augmented reality (AR) technology, combined with computer vision algorithms, offers significant potential to enhance surgical visualization by generating GPS-like spatial maps over the patient's anatomy. This study aims to evaluate the usability and impact of our AR surgical guidance system, delivered through Microsoft HoloLens 2 (or equivalent AR/VR goggles such as Magic Leap or Apple Vision Pro), among surgeons while they complete various surgical tasks on cadaveric specimens. Specifically, an assessment of how the AR system influences surgeon performance and user experience during tasks such as suturing and specimen relocation, performed both with and without AR assistance.
Task accuracy (e.g., resection precision) will be measured and survey responses will be collected to assess the system's usability, ease of use, and comfort. Building on prior work where the investigators validated the feasibility and accuracy of AR-guided surgical holograms, this study focuses on advancing the evaluation of the system's usability and impact on performance. The goal is to generate insights into the application of AR guidance in head and neck tumor resection, ultimately contributing to improved intraoperative surgical precision and patient outcomes.
Type d'étude
Inscription (Estimé)
Phase
- Première phase 1
Contacts et emplacements
Coordonnées de l'étude
- Nom: Jie Ying Wu Assistant Professor of Computer Science, PhD
- Numéro de téléphone: 615-343-4996
- E-mail: JieYing.Wu@vanderbilt.edu
Lieux d'étude
-
-
Tennessee
-
Nashville, Tennessee, États-Unis, 37232
- Recrutement
- Vanderbilt University Medical Center
-
Contact:
- Jie Ying Wu Assistant Professor of Computer Science, PhD
- Numéro de téléphone: 615-343-4996
- E-mail: JieYing.Wu@vanderbilt.edu
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Population étudiée
La description
Inclusion Criteria:
- Post-graduate year 1, 2, 3, 4 and 5 (PGY2-5) resident physicians. (no age limit)
- Surgical fellows.
- Attending physicians.
- Prior cadaver lab or surgical experience.
- Any surgeon, regardless of training and experience, who has been involved in the surgeon-pathologist interaction during surgical resection for frozen section and margin clearance assessment.
Exclusion Criteria:
1. Non-physician surgery providers.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Faisabilité de l'appareil
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Augmented Reality (AR)
Participants will be asked to localize simulated margins on tissue resection beds on a fresh-frozen cadaver head. Specimens of skin, buccal, or tongue tissue will be resected by the research team beforehand. Participants will be asked to place pins or stitches where the indicated targets are located. These positions will be recorded by the research team. Participants will first receive oral guidance only, corresponding to common descriptions between pathologists and surgeons. Participants will then reproduce the same task with AR guidance. In this case, the target will be displayed in the see-through AR headset. The target will be overlaid on the resection bed site and follow your head's movements. |
Task accuracy will be evaluated by measuring distances between the points identified with and without AR guidance, and the pathologist-intended target locations. Participants will then complete post-tasks surveys and interviews. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Performance Task accuracy (e.g., resection precision)
Délai: within 90 minutes of AR-guided use
|
Surgeon performance of target re-localization compared with and without the AR-headset.
|
within 90 minutes of AR-guided use
|
|
User Experience
Délai: immediately after the AR-guided task.
|
Assess AR usability, ease of use, and comfort, through surgeon feedback surveys
|
immediately after the AR-guided task.
|
|
Accuracy of overlay alignment
Délai: within 90 minutes of completing the AR-guided task.
|
This will validate the accuracy of overlay alignment through landmark-based (tumor margin relocation) error metrics, which support precision of re-resection tasks.
|
within 90 minutes of completing the AR-guided task.
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Michael Topf, MD, Vanderbilt University Medical Center
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 251090
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .