Deformable Tissue Modelling and Augmented Reality Based Guidance for Head and Neck Tumor Re-Resection Task (SPeAR)

5 de agosto de 2026 atualizado por: Michael Topf, Vanderbilt University Medical Center

Head and neck cancers have one of the highest recurrence rates among solid malignancies, and recurrence is strongly correlated with overall survival. Reducing recurrence rates depends, in part, on the surgeon's ability to accurately re-resect areas of positive or close margins during surgery. Currently, margin status is communicated primarily through verbal descriptions between the surgeon and pathologist, which can be imprecise. This challenge is further compounded by the deformable nature of soft tissues, as once the specimen is resected, the shape and size of the specimen change, making it difficult to accurately map the specimen's margins back onto the surgical site.

Emerging technologies -such as augmented reality (AR), 3D scanning, and advanced soft tissue modeling- offer promising solutions for improving surgical navigation and precision. Building on these advances, an AR-based surgical navigation system was developed specifically for head and neck tumor resections. The system uses a 3D scanner to generate virtual models of both the resected specimen and the patient's surgical site, as demonstrated in prior work. A soft tissue modeling algorithm is then applied to account for specimen shrinkage and deformation, enabling accurate tracking of positive tumor margins. This guidance information is visualized through an AR headset, which overlays the margin data directly onto the patient's surgical site, providing surgeons with real-time visual guidance during re-resection.

In this study, the goal is to evaluate the benefits and usability of this novel navigation software, compared to the standard of care. By assessing surgeon performance and user experience in cadaveric tasks with and without the AR system to identify strengths, limitations, and opportunities for refinement of the system, ultimately advancing surgical precision and improving patient outcomes by reducing recurrence rates.

Visão geral do estudo

Status

Recrutamento

Intervenção / Tratamento

Descrição detalhada

Augmented reality (AR) technology, combined with computer vision algorithms, offers significant potential to enhance surgical visualization by generating GPS-like spatial maps over the patient's anatomy. This study aims to evaluate the usability and impact of our AR surgical guidance system, delivered through Microsoft HoloLens 2 (or equivalent AR/VR goggles such as Magic Leap or Apple Vision Pro), among surgeons while they complete various surgical tasks on cadaveric specimens. Specifically, an assessment of how the AR system influences surgeon performance and user experience during tasks such as suturing and specimen relocation, performed both with and without AR assistance.

Task accuracy (e.g., resection precision) will be measured and survey responses will be collected to assess the system's usability, ease of use, and comfort. Building on prior work where the investigators validated the feasibility and accuracy of AR-guided surgical holograms, this study focuses on advancing the evaluation of the system's usability and impact on performance. The goal is to generate insights into the application of AR guidance in head and neck tumor resection, ultimately contributing to improved intraoperative surgical precision and patient outcomes.

Tipo de estudo

Intervencional

Inscrição (Estimado)

30

Estágio

  • Fase inicial 1

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

  • Nome: Jie Ying Wu Assistant Professor of Computer Science, PhD
  • Número de telefone: 615-343-4996
  • E-mail: JieYing.Wu@vanderbilt.edu

Locais de estudo

    • Tennessee
      • Nashville, Tennessee, Estados Unidos, 37232
        • Recrutamento
        • Vanderbilt University Medical Center
        • Contato:
          • Jie Ying Wu Assistant Professor of Computer Science, PhD
          • Número de telefone: 615-343-4996
          • E-mail: JieYing.Wu@vanderbilt.edu

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho
  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Não

População do estudo

Surgeon-physician, surgical fellow, or post-graduate year 1, 2, 3, 4 and 5 (PGY2-5) resident physicians

Descrição

Inclusion Criteria:

  1. Post-graduate year 1, 2, 3, 4 and 5 (PGY2-5) resident physicians. (no age limit)
  2. Surgical fellows.
  3. Attending physicians.
  4. Prior cadaver lab or surgical experience.
  5. Any surgeon, regardless of training and experience, who has been involved in the surgeon-pathologist interaction during surgical resection for frozen section and margin clearance assessment.

Exclusion Criteria:

1. Non-physician surgery providers.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Viabilidade do dispositivo
  • Alocação: N / D
  • Modelo Intervencional: Atribuição de grupo único
  • Mascaramento: Nenhum (rótulo aberto)

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Outro: Augmented Reality (AR)

Participants will be asked to localize simulated margins on tissue resection beds on a fresh-frozen cadaver head. Specimens of skin, buccal, or tongue tissue will be resected by the research team beforehand.

Participants will be asked to place pins or stitches where the indicated targets are located. These positions will be recorded by the research team.

Participants will first receive oral guidance only, corresponding to common descriptions between pathologists and surgeons.

Participants will then reproduce the same task with AR guidance. In this case, the target will be displayed in the see-through AR headset. The target will be overlaid on the resection bed site and follow your head's movements.

Task accuracy will be evaluated by measuring distances between the points identified with and without AR guidance, and the pathologist-intended target locations.

Participants will then complete post-tasks surveys and interviews.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Performance Task accuracy (e.g., resection precision)
Prazo: within 90 minutes of AR-guided use
Surgeon performance of target re-localization compared with and without the AR-headset.
within 90 minutes of AR-guided use
User Experience
Prazo: immediately after the AR-guided task.
Assess AR usability, ease of use, and comfort, through surgeon feedback surveys
immediately after the AR-guided task.
Accuracy of overlay alignment
Prazo: within 90 minutes of completing the AR-guided task.
This will validate the accuracy of overlay alignment through landmark-based (tumor margin relocation) error metrics, which support precision of re-resection tasks.
within 90 minutes of completing the AR-guided task.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Colaboradores

Investigadores

  • Investigador principal: Michael Topf, MD, Vanderbilt University Medical Center

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

18 de fevereiro de 2026

Conclusão Primária (Estimado)

1 de junho de 2029

Conclusão do estudo (Estimado)

1 de junho de 2029

Datas de inscrição no estudo

Enviado pela primeira vez

30 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

30 de junho de 2026

Primeira postagem (Real)

7 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

10 de agosto de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

5 de agosto de 2026

Última verificação

1 de junho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 251090

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Descrição do plano IPD

NIH requires through Data Management and Sharing Plans (DMSP) that all data collected during the research project be archived indefinitely and shared with the community after the project termination. De-identified data will then be transferred to Open Science Framework (OSF).

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .