- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07687329
Direct vs Indirect In-House Clear Aligners vs Fixed Appliances in Orthodontic Treatment
4 juillet 2026 mis à jour par: Ahmet Yağcı, TC Erciyes University
Comparison Of Efficiency And Treatment Duration Between Clear Aligners Manufactured Directly And Indirectly By The Clinician And Fixed Orthodontic Treatment: An In Vivo Randomized Clinical Trial
Clear aligner therapy has become increasingly popular as an esthetic alternative to conventional braces in orthodontic treatment.
While clear aligners are traditionally manufactured by commercial laboratories using a thermoforming technique, recent advances in 3D printing technology now allow clinicians to produce aligners directly in their own clinic, either by printing the aligner itself (direct method) or by printing a model and then thermoforming the aligner over it (indirect method)."
"This study compares three approaches to orthodontic treatment in patients with mild to moderate dental crowding who do not require tooth extraction: clear aligners produced directly in-house using 3D printing with a shape-memory resin, clear aligners produced indirectly in-house using a 3D-printed model and thermoforming, and conventional fixed orthodontic treatment with metal brackets and wires."
"A total of 36 patients aged 12 to 30 years were randomly assigned to one of these three treatment groups, and 33 patients completed the study.
Treatment quality was evaluated using the American Board of Orthodontics Objective Grading System (ABO-OGS), an objective scoring method based on dental models obtained at the end of treatment.
The total duration of treatment, from the start of active treatment to its completion, was also compared among the three groups."
"The findings of this study may help clinicians and patients better understand the advantages and limitations of in-house clear aligner production compared to conventional fixed appliances, particularly regarding treatment efficiency and duration.
Aperçu de l'étude
Statut
Complété
Les conditions
Type d'étude
Interventionnel
Inscription (Réel)
36
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Lieux d'étude
-
-
Melikgazi
-
Kayseri, Melikgazi, Turquie (Türkiye)
- Erciyes University, Faculty of Dentistry, Department of Orthodontics
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
Accepte les volontaires sains
Non
La description
Inclusion Criteria:
- Presence of permanent dentition (no primary teeth remaining)
- Non-extraction orthodontic treatment plan
- Age between 12 and 30 years
- Mild to moderate dental crowding (0-6 mm)
- Skeletal Class I classification (ANB: 2±2°)
- Normal vertical growth direction (Sn-GoGn: 32±6°)
- No congenital tooth agenesis (excluding third molars)
- No atypical tooth shapes
- No extracted permanent teeth
- No dental caries
- Good oral hygiene
- Healthy periodontal tissues
Exclusion Criteria:
- Presence of craniofacial anomalies
- Systemic disease or condition
- Previous fixed orthodontic treatment
- History of allergy to dental materials
- History of xerostomia
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Group A ( Direct - In-House)
Participants received clear aligners manufactured directly by the clinician using 3D printing with a shape-memory resin (Tera Harz TC-85, Graphy Inc., Seoul, Korea).
|
Clear aligners fabricated directly by the clinician using a stereolithography (SLA) 3D printer (Asiga MAX UV) with a shape-memory resin (Tera Harz TC-85, Graphy Inc., Seoul, Korea).
The shell of the aligner was designed digitally using Direct Aligner Designer software and printed directly, without the need for a physical model.
Printed aligners were post-processed by centrifugation to remove excess resin, followed by UV light curing.
|
|
Expérimental: Group B ( Indirect - In-House)
Participants received clear aligners manufactured indirectly by the clinician via 3D-printed models followed by thermoforming with CA Pro+ sheets (SCHEU-DENTAL GmbH, Iserlohn, Germany).
|
Clear aligners fabricated indirectly by the clinician via 3D-printed dental models (Asiga MAX UV printer) followed by thermoforming using CA Pro+ sheets (0.75 x 120 mm, SCHEU-DENTAL GmbH, Iserlohn, Germany) with a pressure-forming machine (MINISTAR S).
The thermoformed aligners were trimmed from the printed model after shaping.
|
|
Comparateur actif: Group C (Fixed Orthodontic Treatment)
Participants received conventional fixed orthodontic treatment with metal brackets (AO Mini Master Roth 018).
|
Conventional fixed orthodontic treatment using metal brackets (AO, Mini Master Roth 018, ) bonded to the upper and lower dental arches with stainless steel archwires.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Treatment Quality Assessed by the American Board of Orthodontics Objective Grading System (ABO-OGS)
Délai: From the date of treatment initiation (attachment placement or bracket bonding) until the date of treatment completion (final day of aligner use or bracket debonding), assessed up to 13 months
|
Post-treatment dental models were evaluated using the ABO Objective Grading System, which scores eight criteria: tooth alignment, marginal ridge height, buccolingual inclination, overjet, occlusal contacts, occlusal relationships, interproximal contacts, and root angulation.
Lower total scores indicate better treatment quality.
Scores were classified as successful (<20), borderline (20-30), or unsuccessful (>30).
|
From the date of treatment initiation (attachment placement or bracket bonding) until the date of treatment completion (final day of aligner use or bracket debonding), assessed up to 13 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Total Treatment Duration
Délai: From the date of treatment initiation (attachment placement or bracket bonding) until the date of treatment completion (final day of aligner use or bracket debonding), assessed up to 13 months
|
The total duration of treatment was calculated as the time interval between treatment initiation (aligner delivery or bracket bonding) and treatment completion (final day of aligner use or bracket debonding)
|
From the date of treatment initiation (attachment placement or bracket bonding) until the date of treatment completion (final day of aligner use or bracket debonding), assessed up to 13 months
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Ahmet Yağcı, Prof. Dr., Erciyes University, Faculty of Dentistry, Department of Orthodontics
- Directeur d'études: Musa Göksu, DDS, Erciyes University, Faculty of Dentistry, Department of Orthodontics
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude (Réel)
15 février 2024
Achèvement primaire (Réel)
15 mars 2025
Achèvement de l'étude (Réel)
15 mars 2025
Dates d'inscription aux études
Première soumission
28 juin 2026
Première soumission répondant aux critères de contrôle qualité
4 juillet 2026
Première publication (Réel)
7 juillet 2026
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
7 juillet 2026
Dernière mise à jour soumise répondant aux critères de contrôle qualité
4 juillet 2026
Dernière vérification
1 juin 2026
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- TDH-2024-14031
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
NON
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Non
Étudie un produit d'appareil réglementé par la FDA américaine
Non
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .