Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Development of a Torso Patch Sensor (C-TraQ) as a Companion Device to a Fingertip Sensor (TipTraQ) for Direct Monitoring of Respiratory Effort

29 juillet 2026 mis à jour par: PranaQ Pte. Ltd.

Development and Validation of Chest Patch Sensor for Physiological Signal Measurement and Sleep Apnea Evaluation

The existing PranaQ system utilizes a fingertip sensor that captures PPG(Photoplethysmography) and accelerometer data, and its clinical validation is well-established. While PPG alone has shown effectiveness in diagnosing obstructive sleep apnea, its limited data channels restrict comprehensive evaluation. For instance, it struggles to link apnea events with body position or differentiate between central and obstructive sleep apnea.

To address these limitations, the PranaQ system incorporates new sensors, specifically the chest patch sensor, to monitor respiratory movements via accelerometer signals. The additional respiration signal has the potential to improve diagnostic accuracy for apnea through additional information from respiratory effort.

Aperçu de l'étude

Description détaillée

Disease Background Sleep apnea-hypopnea syndrome (SAHS) represents a pervasive and significant public health challenge, affecting a substantial segment of the adult population. Epidemiological data indicate that 34% of men and 17% of women between the ages of 30 and 70 are impacted by this condition. Despite its high prevalence, SAHS remains vastly underdiagnosed and consequently undertreated, leaving a large portion of the affected population vulnerable to its associated health risks.

The established gold standard for the definitive diagnosis of sleep apnea is full-channel polysomnography (PSG). This comprehensive diagnostic procedure necessitates the simultaneous recording of a multitude of physiological and biological signals throughout the night, including electroencephalography (EEG) to monitor brain activity and sleep stages, electrooculography (EOG) for eye movements, electromyography (EMG) for muscle activity, and dedicated sensors for airflow, respiratory effort, and blood oxygen saturation.

However, the clinical utility and accessibility of PSG are severely constrained by several inherent limitations. The study is highly uncomfortable, requiring patients to be affixed with a complex array of over 20 sensors and leads. Crucially, PSG is exclusively a hospital-based procedure, confining patients to an unfamiliar environment which can itself negatively impact natural sleep patterns (the "first-night effect"). Furthermore, the subsequent analysis of the multichannel PSG data is resource-intensive, demanding hours of expert technician time for the meticulous labeling and scoring of individual sleep breathing events, which contributes to its high cost, significant time commitment, and impracticality for widespread population screening or routine follow-up evaluation. These barriers highlight the urgent need for more accessible, less burdensome, and cost-effective diagnostic alternatives for sleep apnea.

Description of PranaQ system

The PranaQ system integrates multiple wearable sensors-one for the fingertip and one for the chest-with a mobile application and an interpretable AI platform. The sensors collect the following data:

  1. T-TraQ (Fingertip Sensor): Records Photoplethysmography (PPG), accelerometer, and temperature data from the fingertip.
  2. C-TraQ (Torso Patch Sensor): Also collects PPG, accelerometer, and temperature data. In this study, there are three sensors attached over sternum, abdomen and left subclavicle area.

The PranaQ system, composed of wearable devices and cloud computing, is designed for both home and clinical settings to aid in the evaluation and diagnosis of suspected adult sleep apnea patients, as well as for long-term monitoring. Its function includes recording, storing, and exporting physiological waveforms. After the patient completes the recording, the collected signal data will be sent to the cloud for automatic report generation. The final sleep report will then be sent back to the healthcare provider through a browser-based user interface (PranaQ Expert Panel).

Clinical Evaluation Objectives and Purpose

  1. Validate the respiration information generated by the C-TraQ (Chest Patch Sensor). The raw signal from the chest patch is accelerometer-based. The respiration rate and waveform generated from the chest patch signal will be compared for consistency with information concurrently obtained from the thorax and abdominal belt collected through the PSG.
  2. Validate the multi-sensor PranaQ system for the diagnosis of sleep apnea The TST, TRT, ODI, and AHI(both obstructive and central) generated by the PranaQ system will be compared with the results from PSG labeled by a technician.

Type d'étude

Observationnel

Inscription (Estimé)

180

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Ke Wei Chen, M.D.
  • Numéro de téléphone: +886-2-77415277
  • E-mail: kwchen@pranaq.com

Lieux d'étude

    • Taiwan
      • Taipei, Taiwan, Taïwan, 201
        • Recrutement
        • Taipei Veterans General Hospital
        • Contact:
          • Chun-Hsien Tseng Sleep Technician
          • Numéro de téléphone: 886-2-2875-7564
          • E-mail: cmd@vghtpe.gov.tw

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Oui

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patient who is scheduled for a sleep study.

La description

Inclusion Criteria:

  • Subjects must be 18 years of age or older.

Exclusion Criteria:

  • Opioids use
  • Chronic Obstructive Lung Disease, Global Initiative for Chronic Obstructive
  • Lung Disease (GOLD) categorization 3 or 4
  • Devastating strokes, with a modified Rankin score (mRS) ≥ 4
  • Interstitial lung disease

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Respiratory Rate
Délai: one night
PSG recording estimated respiratory rate as ground truth to compare with the C-TraQ-generated respiratory rate.
one night
Sleep Position
Délai: One night
Sleep Position measured by PSG as ground truth to compare with C-TraQ generated sleep position
One night
AHI
Délai: One night
Technician labeled AHI based on PSG signal to compare with PranaQ system's prediction.
One night

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

5 juin 2026

Achèvement primaire (Estimé)

23 mars 2027

Achèvement de l'étude (Estimé)

23 mars 2027

Dates d'inscription aux études

Première soumission

29 juillet 2026

Première soumission répondant aux critères de contrôle qualité

29 juillet 2026

Première publication (Réel)

4 août 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

4 août 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

29 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner