Accuracy of 3D Electrical Impedance Tomography for Assessing Lung Ventilation

4 août 2026 mis à jour par: Shanghai Zhongshan Hospital

Accuracy of Three-Dimensional Electrical Impedance Tomography for Assessing Dynamic Regional Lung Ventilation Validated by Four-Dimensional CT: A Prospective Observational Study

This prospective observational study will evaluate how accurately three-dimensional electrical impedance tomography (3D-EIT) measures the distribution of air in the lungs during breathing when compared with four-dimensional computed tomography (4D-CT).

3D-EIT is a noninvasive, radiation-free imaging method that measures changes in electrical impedance across the chest and can provide continuous information about regional lung ventilation. In this study, 4D-CT will be used as the reference method because it can provide detailed images of changes in the lungs throughout the breathing cycle.

Approximately 50 adults, including healthy volunteers and hospitalized patients who are able to undergo both examinations, will be enrolled at a single center. EIT and CT data will be collected at the same time during stable breathing. Researchers will compare the two methods to determine how closely their measurements of ventilation in different lung regions agree. The study will also explore whether EIT can detect changes in regional ventilation under different breathing conditions.

The study will not use the research EIT results to make clinical treatment decisions. The findings may support the future use of EIT as a noninvasive, radiation-free method for monitoring regional lung ventilation.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Estimé)

50

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Oui

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

The study population will include adults aged 18 years or older recruited at the Department of Critical Care Medicine, Zhongshan Hospital, Fudan University. Participants will consist of healthy volunteers and intensive care unit patients for whom CT imaging is considered necessary based on the treating physician's clinical judgment. Eligible participants must be able to undergo simultaneous 4D-CT and 3D-EIT monitoring.

This is a prospective, observational, single-center study. Participation will not alter the participant's routine clinical management, and the research-derived three-dimensional EIT reconstruction results will not be used directly to make clinical treatment decisions.

La description

Inclusion Criteria:

  • Age 18 years or older.
  • Healthy volunteers or patients in the intensive care unit for whom CT imaging is considered necessary based on the treating physician's clinical judgment.
  • Able to cooperate with or undergo simultaneous 4D-CT and 3D-EIT monitoring.
  • Able to provide written informed consent personally or through a legally authorized representative, as applicable.

Exclusion Criteria:

  • Unable to tolerate or having a contraindication to 4D-CT examination, including pregnancy or severe respiratory distress.
  • Extensive chest skin injury or infection, or any condition preventing placement of the EIT electrode belt.
  • Body size or chest deformity that may substantially limit the quality of EIT or CT data, including chest circumference outside the compatible range of the EIT device.
  • Presence of an implanted electronic device that may interfere with EIT signals, such as a cardiac pacemaker.
  • Unable to complete simultaneous 4D-CT and 3D-EIT monitoring because of significant motion, persistent coughing, poor cooperation, or other technical or clinical reasons.
  • Any other condition that, in the investigator's judgment, makes the individual unsuitable for participation in the study.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Paired 3D-EIT and 4D-CT Assessment Cohort
This single cohort will include approximately 50 adults, including healthy volunteers and hospitalized patients, who are able to undergo synchronous 3D-EIT and 4D-CT data acquisition. Regional lung ventilation measurements obtained by the two methods during the same breathing cycle will be compared for agreement and accuracy. Participants will not be assigned to different study groups, and the research EIT results will not be used to direct clinical treatment.
Regional lung ventilation data will be collected using a chest electrical impedance tomography system (V200-S). Electrical impedance changes in the chest will be measured continuously and reconstructed to assess three-dimensional regional ventilation distribution. EIT data will be acquired synchronously with dynamic computed tomography data and will be used for research analysis only. The research EIT results will not directly guide clinical treatment decisions.
Autres noms:
  • 3D-EIT
Dynamic chest computed tomography data will be acquired using an X-ray computed tomography system (uCT 610 Sim) during one or more breathing cycles. The images will be reconstructed and analyzed to quantify changes in regional lung air volume and ventilation distribution. The 4D-CT measurements will serve as the reference method for comparison with 3D-EIT measurements.
Autres noms:
  • 4D-TDM

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Deming and Passing-Bablok Regression Slopes and Intercepts Comparing Regional Ventilation Fraction Measured by 3D-EIT and 4D-CT
Délai: Periprocedural, during synchronous 3D-EIT and 4D-CT acquisition at the study visit; one respiratory cycle is from the onset of one inspiration to the onset of the next.
For each participant, paired regional ventilation fraction measurements obtained by 3D-EIT and 4D-CT during the same synchronized respiratory cycle will be analyzed. Regional ventilation fraction will be expressed as the percentage of total ventilation within each predefined lung region. Prespecified regions may include the ventral and dorsal lung regions, dependent and nondependent regions, and the left and right lungs. Agreement between the two methods will be assessed using Deming regression and Passing-Bablok regression. Regression slopes, intercepts, and their 95% confidence intervals will be reported. A slope closer to 1 and an intercept closer to 0 indicate better agreement between the two methods.
Periprocedural, during synchronous 3D-EIT and 4D-CT acquisition at the study visit; one respiratory cycle is from the onset of one inspiration to the onset of the next.

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Pearson Correlation Coefficient Between Regional Ventilation Fraction Measurements Obtained by 3D-EIT and 4D-CT
Délai: Periprocedural, during the synchronous 3D-EIT and 4D-CT acquisition at the study visit
Paired regional ventilation fraction measurements obtained from spatially and temporally aligned 3D-EIT and 4D-CT ventilation data will be evaluated using the Pearson correlation coefficient. Regional ventilation fraction will be expressed as the percentage of total ventilation within each predefined lung region. Analyses will be performed for predefined regions, including the ventral and dorsal regions, left and right lungs, and dependent and nondependent regions, as applicable. Pearson correlation coefficients and their 95% confidence intervals will be reported.
Periprocedural, during the synchronous 3D-EIT and 4D-CT acquisition at the study visit
Mean Bias and 95% Limits of Agreement Between Regional Ventilation Fraction Measurements Obtained by 3D-EIT and 4D-CT
Délai: Periprocedural, during the synchronous 3D-EIT and 4D-CT acquisition at the study visit
Agreement between paired regional ventilation fraction measurements obtained by 3D-EIT and 4D-CT will be evaluated using Bland-Altman analysis. Regional ventilation fraction will be expressed as the percentage of total ventilation within each predefined lung region. The mean difference between the two methods, corresponding 95% confidence interval, and the lower and upper 95% limits of agreement will be reported.
Periprocedural, during the synchronous 3D-EIT and 4D-CT acquisition at the study visit

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 septembre 2026

Achèvement primaire (Estimé)

31 décembre 2026

Achèvement de l'étude (Estimé)

1 juillet 2027

Dates d'inscription aux études

Première soumission

30 juillet 2026

Première soumission répondant aux critères de contrôle qualité

4 août 2026

Première publication (Réel)

10 août 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

10 août 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 août 2026

Dernière vérification

1 août 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • B2026-447

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .