- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT07840937
Feasibility Study of E-Fusion Vasopressor Titration-Assist During Multi-Level Spine Surgery
Feasibility Study of E-Fusion Vasopressor Titration-Assist as a Clinical Decision Support Tool During Multi-Level Spine Surgery
This is a single-arm feasibility study of E-Fusion Vasopressor Titration-Assist, a clinical decision support software, in 10 adults undergoing multi-level spine surgery. E-Fusion monitors blood pressure from the patient monitor and displays recommended changes to the norepinephrine infusion rate. The anesthesia provider independently reviews each recommendation and may accept or ignore it. The software does not connect to or control the infusion pump. The primary objective is to assess safety by evaluating adverse events attributable to E-Fusion during surgery. Secondary objectives evaluate clinician agreement with the recommendations and blood pressure management.
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Tanulmány típusa
Beiratkozás (Becsült)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi kapcsolat
- Név: Behnood Gholami, PhD
- Telefonszám: 347-774-1617
- E-mail: info@autonomoushealthcare.com
Tanulmányi helyek
-
-
North Carolina
-
Winston-Salem, North Carolina, Egyesült Államok, 27157
- Wake Forest University Health Sciences
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Age 22 years or older
- Patient or a legally authorized representative (LAR) has provided written informed consent
- Patient is expected to receive norepinephrine through a central line, PICC line, or peripheral line for blood pressure management
- Patient's blood pressure is monitored with an arterial line
- Patient is undergoing multi-level spine surgery with an expected duration of at least 2 hours and not exceeding 8 hours
Exclusion Criteria:
- Confirmed pregnancy and/or nursing mothers
- Currently participating in another interventional study
- Patients who are likely to bleed excessively and/or need rapid transfusion
- Patients expected to be disconnected and transported for imaging during the study procedure
- History of cardiac arrhythmias
- Patients receiving another actively titrated vasopressor during study (excluding vasopressin)
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Az eszköz megvalósíthatósága
- Kiosztás: N/A
- Beavatkozó modell: Egyetlen csoportos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: E-Fusion clinical decision support
All subjects receive standard anesthetic care. E-Fusion displays advisory norepinephrine infusion rate recommendations that the anesthesia provider may accept or ignore. |
Clinical decision support software that monitors mean arterial pressure from the patient monitor and displays recommended norepinephrine infusion rate changes. The clinician independently evaluates each recommendation and makes all infusion rate changes manually. The software does not connect to or control the infusion pump. |
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Number of adverse events and serious adverse events of relevance attributed to E-Fusion
Időkeret: Intraoperative period, from E-Fusion activation to deactivation or end of surgery, up to 8 hours
|
Number of adverse events (AEs) and serious adverse events (SAEs) of relevance occurring during surgery, attributed to E-Fusion based on clinician assessment, including major adverse cardiac events, intraoperative arrhythmia, and infusion-related injury. |
Intraoperative period, from E-Fusion activation to deactivation or end of surgery, up to 8 hours
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Percentage of E-Fusion suggested dose changes in agreement with the anesthesia provider
Időkeret: Intraoperative period, up to 8 hours
|
Percentage of E-Fusion suggested dose changes in agreement with the anesthesia provider after their independent review. |
Intraoperative period, up to 8 hours
|
|
Time-weighted average mean arterial pressure (TWA-MAP) above and below target
Időkeret: Intraoperative period, up to 8 hours
|
Time-weighted average MAP above and below the clinician-set target, stratified by compliance group: high (greater than 80%), medium (50-80%), and low (less than 50%) compliance with E-Fusion recommendations. |
Intraoperative period, up to 8 hours
|
Együttműködők és nyomozók
Szponzor
Együttműködők
Nyomozók
- Kutatásvezető: Ashish Khanna, MD, Wake Forest University Health Sciences
- Tanulmányi igazgató: Behnood Gholami, PhD, Autonomous Healthcare, Inc.
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Becsült)
Elsődleges befejezés (Becsült)
A tanulmány befejezése (Becsült)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Egyéb vizsgálati azonosító számok
- EF-SPINE-001
- 1R43HL187059-01 (Az Egyesült Államok NIH támogatása/szerződése)
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .