Assessing Blood Pressure Variability in a Healthy Adult Population During Transcutaneous Hypoglossal Nerve Stimulation With the Zeus Sleep Device (Zeus-BPV)

2026. november 3. frissítette: Royal Brompton & Harefield NHS Foundation Trust

Transcutaneous hypoglossal nerve stimulation is an emerging treatment option for Obstructive Sleep Apnoea (OSA), a sleep condition where breathing is repeatedly limited. The standard treatment for OSA is not always well tolerated therefore, more alternatives are needed.

Transcutaneous hypoglossal nerve stimulation uses a device, such as Zeus, which sticks underneath the chin to deliver electrical pulses during sleep. These pulses stimulate the hypoglossal nerve to prevent the tongue from relaxing and blocking the airway.

Device placement is important for specific nerve targeting; however, its proximity is close to receptors involved in blood pressure regulation. Whilst current research indicates that transcutaneous stimulation is unlikely to increase blood pressure, OSA patients have an increased risk of developing high blood pressure, therefore treatment options should not make this worse. Further research to understand the impact of transcutaneous hypoglossal nerve stimulation on blood pressure is therefore needed. In this study, the blood pressure of participants will be measured whilst they wear the Zeus sleep device. It is expected that blood pressure will either decrease or remain constant in line with current research. Findings could facilitate improved confidence in device use for OSA treatment and provide patients with alternative treatment options.

A tanulmány áttekintése

Állapot

Toborzás

Beavatkozás / kezelés

Részletes leírás

During sleep the upper-airway muscles relax, in obstructive sleep apnoea (OSA) this causes repeated narrowing (hypopnoea) and obstruction (apnoea) (NICE, 2021). These periods of reduced breathing cause arousals fragmenting sleep. Symptoms include snoring, impaired performance, waking headaches, and excessive daytime sleepiness (Arnardottir et al., 2016, Spicuzza et al., 2015). OSA additionally impacts quality of life and cognition (Vaessen et al., 2015) and increases risks of hypertension and cardiovascular morbidity (Peppard et al., 2000, Nieto, 2000, Marin et al., 2012). Diagnosis of OSA uses sleep studies, requiring an apnoea hypopnoea index (AHI) of ≥5/hr (NICE, 2021). Peppard et al. (2013) estimate the prevalence of sleep disordered breathing, of which OSA is the most common, to be 26% of 30-70-year-olds and rising.

The gold standard treatment of OSA is continuous positive airway pressure (CPAP) (NICE, 2021), requiring >4hrs/night usage for effective treatment and risk reduction; however, CPAP is not always well tolerated. A review by Weaver et al. (2008) found CPAP nonadherence rates of 29-83%. Alternative treatments include positional modifiers, mandibular advancement devices, and surgery (NICE, 2021, Spicuzza et al., 2015) whose usage is limited by pathophysiology. Further CPAP alternatives are needed.

Hypoglossal nerve stimulation (HNS) is an emerging OSA therapy which uses electrical stimulation to contract the genioglossus muscle, preventing prolapse and maintaining airway patency (NICE, 2017). Strollo et al. (2014) conducted a prospective, single-group, cohort study where non-CPAP compliant OSA patients had a subcutaneous HNS device implanted. A clinically significant decrease in median AHI of 68% (29.3 to 7.4/hr, P<0.001) was seen 12 months post-implantation alongside improved sleepiness and quality of life. A separate study of 113 participants by Woodson et al. (2025) also showed significant improvements in mean AHI (-18.3 ± 11.8/hour, P<0.001) following HNS implantation. Whilst HNS has shown promising efficacy and acceptable safety profile (NICE, 2017, Strollo et al., 2014, Woodson et al. 2025, Friedman et al. 2016), HNS requires a general anaesthesia and carries all the associated risks and costs of an invasive procedure. Interest has therefore turned to transcutaneous HNS as a non-invasive, cost-efficient alternative.

According to Steier et al. (2011), transcutaneous electrical stimulation (TESLA) of the hypoglossal nerve via bilateral hydrogel patches located in the submental area causes contraction of the genioglossus muscle similarly to subcutaneous HNS. A recent randomised controlled trial in OSA patients by Ratneswaran et al., (2023) compared TESLA to usual care (CPAP). An adjusted reduction in AHI of 7/hr with TESLA was seen at 3 months, however this was not significant (P=0.12) potentially due to small sample size or absent additional interrogation. Indeed, Pengo et al. (2016) indicated that only some participants are responders to TESLA, in their randomised, sham-controlled crossover trial a significant reduction in AHI was only seen in responders (9.1/hr, p=0.004). Meta-analysis by Wang et al. (2025) and Young Jae Byun et al. (2020) both concluded that TESLA results in a meaningful AHI reduction. TESLA appears to be well tolerated by patients with minimal adverse events (Pengo et al., 2016, Ratneswaran et al., 2023, Reed et al., 2016).

Despite the promising research, it is possible that submental electrical stimulation could affect blood pressure due to its proximity to carotid sinus baroreceptors. A similar device to TESLA, TENS machines, are contraindicated for use in the neck region (NHS, 2017). However, a sham-controlled, randomized crossover trial of HNS in 60 participants by Dedhia et al., (2023) concluded there was not a significant difference in mean 24-systolic blood pressure between sham and active groups. Furthermore, a study by Alsharifi et al. (2023) found submental TESLA in 13 healthy participants caused a significant decrease in blood pressure (systolic: p=4.93E-06, diastolic: p=3.48E-09, mean: p=3.88E-08); supported by a meta-analysis that concluded electrical stimulation of the upper airways reduced both systolic and diastolic blood pressure (Khaled et al., 2025). Whilst current evidence indicates that TESLA is unlikely to elicit hypertension, in a patient cohort already at increased risk of hypertension and cardiovascular morbidity, it is vital risk is not compounded by treatment.

This study aims to evaluate the short-term impact of hypoglossal nerve TESLA on blood pressure. We hypothesise that submental TESLA will not increase blood pressure or short-term blood pressure variability and may lead to modest reductions, consistent with previous studies.

Tanulmány típusa

Beavatkozó

Beiratkozás (Becsült)

30

Fázis

  • Nem alkalmazható

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi kapcsolat

Tanulmányozza a kapcsolattartók biztonsági mentését

Tanulmányi helyek

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

18 év és régebbi (Felnőtt, Idősebb felnőtt)

Egészséges önkénteseket fogad

Igen

Tanulmányozható nemek

Összes

Leírás

Inclusion Criteria:

  1. Adults aged 18 or older
  2. Either biological sex
  3. Healthy volunteers
  4. Able to provide informed consent
  5. No contraindications to hypoglossal nerve stimulation using the Zeus device
  6. BMI >18.5 and <30kg/m2

Exclusion Criteria:

  1. Skin allergy, including eczema or allergic contact dermatitis in device placement area
  2. Diagnosed heart condition or cardiovascular disease
  3. Cardiovascular event in the previous 2 months
  4. Implanted medical devices including cardioverter defibrillator and pacemaker
  5. Previous or current cardiac arrhythmia
  6. Autonomic neuropathy
  7. Neuromuscular disease
  8. Diagnosed epilepsy or recurrent seizures
  9. Hypertension (>140/90 mmHg)
  10. Hypotension (<95/65 mmHg)
  11. Metal work in the head or neck, excluding dental fillings
  12. Current migraine
  13. Pregnancy
  14. Diagnosed or suspected deep vein thrombosis within previous 2 months
  15. Recent cancer diagnosis or cancerous legions in proximity to device placement area
  16. Alcohol dependence
  17. Recent infection requiring hospital admission or medical treatment within the previous month, including leprosy
  18. Swollen, inflamed, infected, or broken skin in device placement area
  19. Recent surgery within 10 months in, or near, device placement area
  20. Currently taking medications, excluding contraceptive medication
  21. Long facial hair in device placement area

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Elsődleges cél: Alapvető tudomány
  • Kiosztás: Véletlenszerűsített
  • Beavatkozó modell: Crossover kiosztás
  • Maszkolás: Nincs (Open Label)

Fegyverek és beavatkozások

Résztvevő csoport / kar
Beavatkozás / kezelés
Kísérleti: Group 1- Active stimulation followed by sham stimulation

Transcutaneous hypoglossal nerve stimulation using the Zeus Sleep device

Kísérleti: Group 2- Sham stimulation followed by active stimulation

Transcutaneous hypoglossal nerve stimulation using the Zeus Sleep device

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Időkeret
Change from baseline in systolic and diastolic blood pressure during Zeus sleep device usage
Időkeret: baseline, intervention
baseline, intervention

Másodlagos eredményintézkedések

Eredménymérő
Időkeret
Change in pulse rate variability from baseline during active stimulation
Időkeret: baseline, intervention
baseline, intervention

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Tényleges)

2026. szeptember 29.

Elsődleges befejezés (Becsült)

2027. február 19.

A tanulmány befejezése (Becsült)

2027. március 29.

Tanulmányi regisztráció dátumai

Először benyújtva

2026. szeptember 25.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2026. november 3.

Első közzététel (Tényleges)

2026. november 4.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2026. november 4.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2026. november 3.

Utolsó ellenőrzés

2026. november 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Egyéb vizsgálati azonosító számok

  • 368532

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

ELDÖNTETLEN

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

Iratkozz fel