Early Mechanical Insufflation-Exsufflation in Mechanically Ventilated ICU Patients (FREE-BREATH) (FREE-BREATH)
Early Use of Mechanical Insufflation-Exsufflation to Improve Weaning Efficiency in Mechanically Ventilated Critically Ill Patients: A Randomized Controlled Trial (FREE-BREATH)
Cough insufficiency is one of the main complications in critically ill patients undergoing mechanical ventilation, whether invasive or non-invasive. This impairment is multifactorial, involving both mechanical factors (endotracheal intubation, reduced expiratory muscle strength) and neurological/systemic factors (delirium, sedation, ICU-acquired weakness), leading to ineffective bronchial clearance, secretion retention, atelectasis, respiratory infections, and an increased risk of weaning failure and reintubation.
Mechanical Insufflation-Exsufflation (MI-E) is a cough augmentation technique that simulates the physiology of a natural cough by alternating positive and negative pressure, generating a forced expiratory flow that promotes bronchial clearance. While historically used in neuromuscular disease populations, more recent evidence suggests it may also improve secretion clearance in intubated critically ill patients.
This single-center, prospective, randomized controlled trial (no drugs or medical devices under investigation as the intervention device is already approved and in routine clinical use) aims to determine whether early use of MI-E (within 72 hours of intubation) reduces the overall duration of invasive mechanical ventilation by preventing early secretion accumulation and improving weaning efficiency. Secondary aims include the impact on the number of therapeutic bronchoscopies, respiratory complications, and length of hospital stay.
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
Background and Rationale:
Cough augmentation techniques have been developed to improve expulsive efficacy in patients with reduced cough capacity. Among these, Mechanical Insufflation-Exsufflation (MI-E) simulates the physiology of cough by alternating positive and negative pressure, generating a forced expiratory flow that facilitates bronchial clearance. Several studies suggest its efficacy compared with standard endotracheal suctioning, which often fails to remove secretions from peripheral airways and is associated with greater discomfort and pain for the patient.
MI-E has historically been used in populations with neuromuscular disease, but has more recently shown potential for improving secretion clearance in intubated critically ill patients as well, significantly increasing peak expiratory flow compared with manual techniques and improving secretion mobilization and expulsion both in people with chronic neurological conditions and in critically ill patients.
Some studies have shown a favorable effect on successful extubation and on the prevention of ventilator-associated pneumonia in patients treated with MI-E. Other studies suggest that cough augmentation techniques may favor successful removal of the endotracheal tube and reduce time spent on mechanical ventilation, without adverse events; however, the limited number of participants makes it difficult to precisely estimate the probability of adverse events.
A Cochrane review analyzed this area but was able to include only 3 studies (only two randomized controlled trials), of low quality on the main outcomes, showing a trend toward reduced mortality and lower risk of adverse events.
Although the use of MI-E is already included in the protocols of some intensive care units, its systematic use in the early phases of admission is not yet standardized nor supported by high-quality evidence from randomized clinical trials. The hypothesis underlying this study is that early use of MI-E, within 72 hours of intubation and initiation of ventilation, may reduce overall mechanical ventilation time by preventing secretion accumulation in the early phases of invasive ventilation and improving weaning efficiency.
The safety of mechanical cough assistance in this setting is generally considered high, with adverse events being minor and of limited clinical relevance, against a background of reduced secretion burden and a lower need for disobstructive bronchoscopies, as also confirmed by the Cochrane review on the topic.
The primary objective of this randomized controlled trial - which does not involve the investigation of any drug or medical device (the MI-E device used is a CE-marked device already in routine clinical use) - is to verify the efficacy of early use of MI-E in reducing the number of days of mechanical ventilation. Secondarily, the study will evaluate the impact on the number of therapeutic bronchoscopies performed during hospitalization, respiratory complications, and length of stay.
Study Design:
Single-center, prospective, randomized, controlled trial with two parallel arms; no investigational drug or medical device is involved (the MI-E device is a CE-marked device already in routine clinical use in the participating units). Following Ethics Committee approval, the study will be registered on ClinicalTrials.gov prior to patient enrollment and will be conducted following the CONSORT (Consolidated Standards of Reporting Trials) guidelines. The TIDieR (Template for Intervention Description and Replication) checklist will be used for reporting the therapeutic interventions.
All procedures will comply with national and institutional ethical standards for human research, in accordance with the Declaration of Helsinki and Good Clinical Practice guidelines. Participants will be clearly and comprehensibly informed of all study details and will be enrolled only after signing informed consent; they retain the right to withdraw from the study at any time, without penalty or compromise to their care. For non-cooperative or unconscious patients, deferred informed consent will be obtained according to the exemption form (Appendix 1).
Total study duration: 24 months. Patient enrollment will take place through the Intensive Care (Rianimazione) and Intensive Therapy (Terapia Intensiva) units of the Ospedale Maggiore Carlo Alberto Pizzardi in Bologna (Italy) during the first 18 months of the study; the following 6 months will be dedicated to completing therapeutic interventions and follow-up, database cleaning, statistical analysis, and drafting of the final report.
Arms and Interventions:
Enrolled patients will be randomized into two homogeneous groups: an experimental group (MI-Eg) and a control group (CTRLg). All participants will receive an equivalent number of physiotherapy sessions, with the same frequency (twice daily) and total duration (20-40 minutes), delivered by physiotherapists with specific training in respiratory rehabilitation.
Control group (CTRLg) Patients will receive respiratory and motor physiotherapy according to a procedure already in use at the hospital. The respiratory component will include therapeutic positioning, endotracheal suctioning - also outside structured sessions when clinically indicated - application of expiratory rib-cage compressions and, when deemed appropriate by the physiotherapist, manual hyperinflation maneuvers. The motor component will include passive, active-assisted and active mobilization of the limbs, with progression toward sitting at the edge of the bed, standing, and ambulation, according to individual clinical tolerance.
Experimental group (MI-Eg) Patients will receive two daily treatment sessions using Mechanical Insufflation-Exsufflation (MI-E), delivered with the CoughAssist™ device (Philips Respironics, CE marked; technical data sheet attached as Appendix 2), already available in the hospital units. Sessions will be conducted in a controlled environment, in intubated or tracheostomized patients, using appropriate interfaces and keeping the tracheal cuff inflated to optimize expulsion efficacy. Each session includes individualized optimization of MI-E settings, following examples reported in the literature, with a gradual increase to effective insufflation-exsufflation pressures, and the settings used are recorded for each patient. Cycles may be repeated until adequate expectoration is achieved, based on patient tolerance and the physiotherapist's clinical judgment. Additional mechanical suctioning may be performed during the day if deemed necessary. All sessions will be thoroughly documented, specifying duration, parameters used, clinical response, and any therapeutic adjustments or interruptions.
Blinding:
Assessment of primary and secondary outcomes will be performed by outcome assessors blinded to group allocation, and data analysis will be conducted by researchers not involved in enrollment, assessment, or treatment. The two treatments (standard care and MI-E) differ in operational procedures and use of specific equipment; therefore, blinding of treating physiotherapists is not feasible.
Tanulmány típusa
Beiratkozás (Becsült)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
Emilia-Romagna
-
Bologna, Emilia-Romagna, Olaszország, 40133
- Ospedale Maggiore "Carlo Alberto Pizzardi" AUSL Bologna
-
Kapcsolatba lépni:
- Diego Lisi, Msc, PT
- Telefonszám: +393294271782
- E-mail: diego.lisi@ausl.bologna.it
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Patients ≥18 years of age
- Invasive mechanical ventilation
- Clinically significant bronchial secretions (≥1 suctioning event per hour in the preceding 24 hours)
Exclusion Criteria:
- Contraindications to MI-E (bullous emphysema, subcutaneous emphysema, undrained or suspected pneumothorax, pneumomediastinum, recent barotrauma, tracheoesophageal fistula) (Breas Medical 2022; Respironics 2012; Chatwin 2023)
- Known neuromuscular disease
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Kezelés
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Kettős
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Egyéb: Control group (CTRLg)
Patients will receive respiratory and motor physiotherapy according to a procedure already in use at the hospital. The respiratory component will include therapeutic positioning, endotracheal suctioning - also outside structured sessions when clinically indicated - application of expiratory rib-cage compressions and, when deemed appropriate by the physiotherapist, manual hyperinflation maneuvers. The motor component will include passive, active-assisted and active mobilization of the limbs, with progression toward sitting at the edge of the bed, standing, and ambulation, according to individual clinical tolerance. |
Patients will receive respiratory and motor physiotherapy according to a procedure already in use at the hospital. The respiratory component will include therapeutic positioning, endotracheal suctioning - also outside structured sessions when clinically indicated - application of expiratory rib-cage compressions and, when deemed appropriate by the physiotherapist, manual hyperinflation maneuvers. The motor component will include passive, active-assisted and active mobilization of the limbs, with progression toward sitting at the edge of the bed, standing, and ambulation, according to individual clinical tolerance.
Más nevek:
|
|
Aktív összehasonlító: Experimental group (MI-Eg)
Patients will receive two daily treatment sessions using Mechanical Insufflation-Exsufflation (MI-E), delivered with the CoughAssist™ device (Philips Respironics, CE marked; technical data sheet attached as Appendix 2), already available in the hospital units. Sessions will be conducted in a controlled environment, in intubated or tracheostomized patients, using appropriate interfaces and keeping the tracheal cuff inflated to optimize expulsion efficacy. Each session includes individualized optimization of MI-E settings, following examples reported in the literature (Chatwin 2023), with a gradual increase to effective insufflation-exsufflation pressures, and the settings used are recorded for each patient. Cycles may be repeated until adequate expectoration is achieved, based on patient tolerance and the physiotherapist's clinical judgment. Additional mechanical suctioning may be performed during the day if deemed necessary. All sessions will be thoroughly documented, specifying durat |
Patients will receive two daily treatment sessions using Mechanical Insufflation-Exsufflation (MI-E), delivered with the CoughAssist™ device (Philips Respironics, CE marked; technical data sheet attached as Appendix 2), already available in the hospital units. Sessions will be conducted in a controlled environment, in intubated or tracheostomized patients, using appropriate interfaces and keeping the tracheal cuff inflated to optimize expulsion efficacy. Each session includes individualized optimization of MI-E settings, following examples reported in the literature (Chatwin 2023), with a gradual increase to effective insufflation-exsufflation pressures, and the settings used are recorded for each patient. Cycles may be repeated until adequate expectoration is achieved, based on patient tolerance and the physiotherapist's clinical judgment. Additional mechanical suctioning may be performed during the day if deemed necessary. All sessions will be thoroughly documented, specifying durati
Más nevek:
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Ventilator-free days (VFD) at 28 days
Időkeret: at 28th days since randomization
|
Composite outcome integrating mortality and duration of mechanical ventilation; the number of days free from mechanical ventilation within a 28-day window (Kubota et al. 2024). |
at 28th days since randomization
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Number of therapeutic (disobstructive) bronchoscopies performed during hospital stay
Időkeret: 28 days from randomization
|
Number of therapeutic (disobstructive) bronchoscopies performed during hospital stay |
28 days from randomization
|
|
Incidence of ventilator-associated pneumonia (VAP), diagnosed according to current CDC/NHSN clinical and microbiological criteria (January 2025 update)
Időkeret: 28 days from randomization
|
Incidence of ventilator-associated pneumonia (VAP), diagnosed according to current CDC/NHSN clinical and microbiological criteria (January 2025 update) |
28 days from randomization
|
|
Total duration of invasive mechanical ventilation, in days
Időkeret: From randomization to extubation or ICU discharge, an average of 7 days
|
Total duration of invasive mechanical ventilation, in days |
From randomization to extubation or ICU discharge, an average of 7 days
|
|
Length of stay in the critical care unit, in days
Időkeret: From randomization to ICU discharge, an average of 10 days
|
Length of stay in the critical care unit, in days |
From randomization to ICU discharge, an average of 10 days
|
|
Health-related quality of life measured with the EuroQol 5-Dimension 5-Level questionnaire (EQ-5D-5L).
Időkeret: At ICU discharge and at 30 days from enrollment
|
The EQ VAS ranges from 0 (worst imaginable health) to 100 (best imaginable health); higher scores indicate better health. |
At ICU discharge and at 30 days from enrollment
|
Együttműködők és nyomozók
Szponzor
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Becsült)
Elsődleges befejezés (Becsült)
A tanulmány befejezése (Becsült)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- CE AVEC 117-2026-OSS-AUSLBO
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
az Egyesült Államokban gyártott és onnan exportált termék
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .