Brain Sensing in Neurological and Psychiatric Disorders

4 maggio 2021 aggiornato da: University College, London

Electrophysiologic Brain Sensing Using Implanted DBS Systems in Neurological and Psychiatric Disorders

High-frequency deep brain stimulation (DBS) is an effective treatment strategy for a variety of movement disorders including Parkinson's disease, dystonia and tremor1-5, as well as for other neurological and psychiatric disorders e.g. obsessive compulsive disorder, depression, cluster headache, Tourette syndrome, epilepsy and eating disorders6-11. It is currently applied in a continuous fashion, using parameters set by the treating clinician. This approach is non-physiological, as it applies a constant, unchanging therapy to a dysfunctional neuronal system that would normally fluctuate markedly on a moment-by moment basis, depending on external stressors, cognitive load, physical activity and the timing of medication administration.

Fluctuations in physical symptoms reflect fluctuations in brain activity. Tracking and responding in real-time to these would allow personalised approaches to DBS through stimulating at appropriate intensities and only when necessary, thereby improving therapeutic efficacy, preserving battery life and potentially limiting side-effects12. Critical to the development of such adaptive/closed-loop DBS technologies is the identification of robust signals on which to base the delivery of variable high-frequency deep brain stimulation.

Local field potentials (LFPs), which are recordable through standard DBS electrodes, represent synchronous neuronal discharges within the basal ganglia. Different LFP signatures have been identified in different disorders, as well as in different clinical states within individual disorders. For example, low frequency LFPs in the Alpha/Theta ranges (4-12Hz) are frequently encountered in patients with Dystonia13,14, while both beta (12-30Hz) gamma (60-90Hz) band frequencies may be seen in Parkinson's disease, when the patient is OFF and dyskinetic, respectively15,16. Equally, suppression of these abnormal basal ganglia signals through medication administration or high-frequency DBS correlates with clinical improvement. As such, they represent attractive electrophysiologic biomarkers on which to base adaptive DBS approaches.

Until recently, neurophysiological assessments were purely a research tool, as they could only be recorded either intra-operatively or for a short period of time post-operatively using externalised DBS electrodes. However, advances in DBS technology now allow real-time LFP recordings to be simply and seamlessly obtained from fully implanted DBS systems e.g. Medtronic Percept PC.

In this study, we will evaluate a cohort of patients with movement disorders and other disorders of basal ganglia circuitry who have implanted DBS systems. Recordings of LFPs and/or non-invasive data such as EEG, limb muscle activation and movement (surface EMG and motion tracking) under various conditions (e.g. voluntary movement, ON/OFF medications, ON/OFF stimulation) will allow us to evaluate their utility as markers of underlying disease phenotype and severity and to assess their potential for use as electrophysiological biomarkers in adaptive DBS approaches. These evaluations in patients with DBS systems with and without LFP-sensing capabilities will take place during a single or multi-day evaluation (depending on patient preference and researcher availability). This study will advance not only the understanding of subcortical physiology in various disorders, but will also provide information about how neurophysiological and behavioural biomarkers can be used to inform personalised, precision closed-loop DBS approaches.

Panoramica dello studio

Stato

Non ancora reclutamento

Descrizione dettagliata

Both hyperkinetic and hypokinetic movement disorders are associated with abnormal spatiotemporal activity within the basal ganglia circuitry13,16,17. This can be assessed through measuring local field potentials (LFPs), which represent the product of synchronous neuronal activity at a given site (unsynchronized, random activity being essentially cancelled out)13. Numerous other disorders such as obsessive compulsive disorder, major depression, Tourette's syndrome, epilepsy, eating disorders and cluster headaches are also amenable to successful modulation using DBS6-11. These disorders likely also have unique, disease-specific electrophysiological signatures, the exact nature of which remains to be thoroughly defined. Abnormal electrophysiological activity is useful not only in delineating the pathophysiologic underpinnings of these disorders, but is central to the future development of adaptive DBS systems which respond in real-time to ameliorate pathological brain acticity12. Adaptive DBS may provide further clinical benefit beyond currently employed continuous DBS approaches, with only a fraction of the energy requirements12.

Studies using microelectrode recordings at the time of DBS lead placement as well as recordings from externalised DBS electrodes have identified distinct neurophysiological signatures within different disorders. Examples include excess beta-frequency oscillations in Parkinsonism, alpha and theta frequency oscillations in dystonia and gamma oscillations in dyskinesia. These neurophysiologic biomarkers of disease can be affected by the application of high-frequency DBS. Future closed-loop DBS systems may rely on real-time suppression of such abnormal basal ganglia activity.

LFPs in Parkinson's disease

A significant body of work has confirmed that beta-frequency oscillations, recorded from both the subthalamic nucleus and the internal portion of the globus pallidus, correlate with severity of bradykinesia and rigidity in Parkinson's disease13,16-18. These beta-frequency oscillations are coherent across simultaneous recordings in different nuclei of the same patient, implying that these represent a network-level dysfunction in Parkinson's disease16,19. The amplitude/power of abnormal beta-frequency LFPs correlates with the severity of motor impairment in Parkinson's disease15,18. Moreover, beta-frequency LFPs can be suppressed both by levodopa administration, or by the application of high-frequency DBS20,21; in both scenarios the degree of suppression in beta-oscillations correlates with the degree of clinical motor improvement. Beta oscillations may therefore represent an electrophysiological parkinsonian symptom correlate which can act as a biomarker of the motor state. Hence, they may be useful signals on which to base stimulation using adaptive DBS technologies. However, some observations, such as the suppression of beta frequency oscillations during periods of tremor, have cast doubt on the robustness of this potential biomarker.

Other LFP frequency alterations have also been observed to correlate with clinical symptomatology in PD. For instance, synchronisation at frequencies in the gamma range (60-90Hz) have been correlated with dyskinesia, as have synchronisation at lower frequencies (4-8Hz)22,23. High-frequency oscillations in the 250Hz range have also been found to associate with parkinsonian clinical states and to shift to even higher frequencies (350Hz) following levodopa administration24. In contrast to beta-frequencies, changes in high-frequency LFPs do appear to correlate with tremor25.

Aside from pure frequency characteristics, the temporal distribution of beta-frequency oscillations has also been examined in different disease states. It is suggested that prolonged periods of beta synchronisation (beta bursts) may be responsible for the overall increase in beta power in patients with Parkinson's disease in the OFF state, and that a move to shorter durations of synchronisation may occur in the ON state26.

LFPs in dystonia

Patients with dystonia display a distinct pattern of LFP alterations in the pallidum13,14, particularly an excess of synchronized oscillatory activity in the low frequency 3-12 Hz band13. Not only is pallidal LFP power prominent in the 3-12Hz band in patients with dystonia13,27 but it correlates with28 and may be coherent with (especially contralateral) dystonic muscular activity29. Moreover, there is a direct association between pallidal low-frequency oscillations and dystonia severity30.

Increased LFP power in the low-frequency band is seen across a variety of dystonia phenotypes. In cervical dystonia, inter-hemispheric differences in LFPs have been demonstrated, though clear correlations with directional head movements have not been established31,32. In myoclonus-dystonia patients, increased pallidal LFP in the 3-15Hz range correlate with dystonic muscle activity33. Oscillatory activity may be different in secondary or combined dystonia, and may also differ according to genetic makeup 34-36.

LFPs in essential tremor

LFP recordings from patients undergoing thalamic DBS in ET have identified distinct thalamic LFP frequency characteristics, often coherent with surface EMG recordings in these groups, at frequencies which are either harmonics or subharmonics of the tremor frequency37.

LFPs in other conditions Electrophysiologic recordings from patients with Tourette's syndrome have shown an excess of low-frequency activity(2-13Hz) in both thalamic and pallidal targets38 and that spontaneous tics in Tourette's syndrome are preceded by coherent thalamo-cortical discharges39. Unique, disease specific LFP patterns have also been identified in a number of neuropsychiatric disorders. For example, prominent alpha activity in the basal ganglia has been suggested as an electrophysiologic correlate of major depressive disorders40

Continuous recording from fully implanted DBS systems has only recently become possible, for example using the Medtronic Percept PC battery system. The quality of signals recorded using this system as well as the correlation with clinical features, and coherence with cortical and motor activity however remain largely unexplored. Moreover, the number of patients on which previous LFP studies has been based is small. Hence, their utility in the future development of closed-loop DBS systems remains uncertain.

Our study will address a number of unanswered questions relating to the utility of LFP recordings in neurological disorders including:

  1. Is it possible to replicate the previous findings concerning LFP signatures in various movement disorders using currently available DBS systems with LFP sensing capabilities e.g. Medtronic Percept PC?
  2. Do LFP signatures persist many years after initiation of deep brain stimulation (most previous studies have evaluated patients only at the time of DBS implantation)?
  3. How are LFP signatures related to modulations of wider brain networks as assessed by EEG?
  4. Can non-invasive recording methods such as EEG provide alternative or complementary biomarkers for closed-loop DBS?
  5. What is the influence of medications, body movements, sensory inputs and differential stimulation parameters on LFPs?
  6. How robust are LFP signatures within and between individuals with similar disease states?
  7. Do robust LFP signatures exist for non movement disorder basal ganglia network pathologies, and how do these correlate with symptoms severity?

Tipo di studio

Osservativo

Iscrizione (Anticipato)

65

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

N/A

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Patients with neurological disorders treated with deep brain stimulation devices capable of neurophysiologic recording

Descrizione

Inclusion Criteria:

  • Age>18 years
  • Neurological or psychiatric disorder treated with a DBS system.
  • Able to give informed consent

Exclusion Criteria:

  • • Inability to tolerate OFF stimulation conditions.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
local field potential power (amplitude)
Lasso di tempo: 12 months
12 months
local field potential frequency (Hz)
Lasso di tempo: 12 months
12 months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Patricia Limousin, PhD, UCL

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Anticipato)

1 luglio 2021

Completamento primario (Anticipato)

1 ottobre 2022

Completamento dello studio (Anticipato)

1 ottobre 2022

Date di iscrizione allo studio

Primo inviato

1 marzo 2021

Primo inviato che soddisfa i criteri di controllo qualità

19 marzo 2021

Primo Inserito (Effettivo)

22 marzo 2021

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

5 maggio 2021

Ultimo aggiornamento inviato che soddisfa i criteri QC

4 maggio 2021

Ultimo verificato

1 maggio 2021

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

INDECISO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Morbo di Parkinson

Sottoscrivi