- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT06700018
Modelli di flusso e trombosi dello stent (TISIS registry)
Sviluppo di un nuovo metodo per la valutazione dettagliata dei modelli di flusso sanguigno nei segmenti dello stent e valutazione del loro ruolo nella trombosi dello stent
The goal of this observational study is to study the effect of haemodynamic forces on thrombus formation and identify haemodynamic markers that predict stent thrombosis events in patients who have undergone OCT-guided percutaneous coronary interventions.
The primary objective of the study is to examine the efficacy of blood flow patterns in predicting stent thrombosis. Researchers will compare the blood flow patterns of the stent thrombosis group with that of the control group to understand the influence of blood flow patterns on thrombus formation and progression.
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
The incidences of Stent Thrombosis (ST) remain high in complex lesions and in high-risk patients. The use of intravascular imaging seems to be able to identify causes of ST, enabling prompt correction, and its use has been associated with better clinical outcomes in this setting. However, the efficacy of intravascular imaging features in predicting ST is limited. Computational fluid dynamic studies have shown that the local hemodynamic forces distribution has an effect on thrombus formation and can be responsible for the ST events. However, none of the studies today has explored in vivo the value of the flow disturbances in predicting events. The investigators have recently developed a method that is able to reconstruct vessel geometry accurately using coronary angiography and optical coherence tomography (OCT) data. Validation of this method in vitro and in human data showed promising results in accurately measuring shear stress and shear rate distribution.
This study, aims to explore the value of this method in predicting patients undergoing stent implantation with OCT imaging guidance that will suffer a ST. The investigators aim to collect data from 40 patients who had an ST after OCT-guided revascularization and from a control group of 80 patients who had no event after having stent implantation under OCT guidance. Investigators will further reconstruct the stented vessel from the OCT and the angiographic images, perform blood flow simulation and measure the shear rate and the shear stress in these two groups to explore the value of these metrics in predicting stent occlusion.
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
-
London, Regno Unito
- Queen Mary University of London
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
A total of 120 patients who have undergone OCT-guided percutaneous coronary intervention and implanted with a second-generation drug-eluting stent
Descrizione
Inclusion Criteria:
- Patients undergone OCT-guided percutaneous coronary intervention and implanted with a second-generation drug-eluting stent
- Patients who have suffered thrombosis post-stent implantation
Exclusion Criteria:
-
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: RETROSPECTIVE
Coorti e interventi
Gruppo / Coorte |
|---|
|
Stent thrombosis group
40 patients who have suffered cardiovascular events attributed to stent thrombosis within one year of post-stent implementation will be recruited. |
|
Control group
80 patients not having suffered stent thrombosis but will have uneventful follow-up. An effort will be made so that these patients have similar clinical presentation, baseline demographics and angiographic results post PCI and receive treatment with a similar antiplatelet regime compared to those who suffered stent thrombosis. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Haemodynamic shear stress and shear rate
Lasso di tempo: 1.5 years
|
The haemodynamic shear rate and shear rate will be calculated by performing CFD simulations on reconstructed geometries obtained from the percutaneous coronary interventions of the patients. The efficacy of the haemodynamic shear stress and shear rate in predicting stent thrombosis will be studied. |
1.5 years
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
OCT based stented segment reconstruction
Lasso di tempo: 3 months
|
To develop a methodology for the reconstruction of stented segments from OCT and angiographic data that relies on the separate modelling of the lumen and stent architecture and fusion of these geometries in a final model |
3 months
|
|
Validation of the proposed reconstruction methodology
Lasso di tempo: 4 months
|
To validate in vivo and in-bench studies, the accuracy of the developed reconstruction method. |
4 months
|
|
Development of automated frame work for reconstruction of stented segments
Lasso di tempo: 6 months
|
To design a user-friendly platform incorporating the new method to fast and accurately reconstruct vessels stented with different stent types. |
6 months
|
Collaboratori e investigatori
Sponsor
Collaboratori
Pubblicazioni e link utili
Pubblicazioni generali
- Stone PH, Saito S, Takahashi S, Makita Y, Nakamura S, Kawasaki T, Takahashi A, Katsuki T, Nakamura S, Namiki A, Hirohata A, Matsumura T, Yamazaki S, Yokoi H, Tanaka S, Otsuji S, Yoshimachi F, Honye J, Harwood D, Reitman M, Coskun AU, Papafaklis MI, Feldman CL; PREDICTION Investigators. Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study. Circulation. 2012 Jul 10;126(2):172-81. doi: 10.1161/CIRCULATIONAHA.112.096438. Epub 2012 Jun 21.
- Gijsen F, Katagiri Y, Barlis P, Bourantas C, Collet C, Coskun U, Daemen J, Dijkstra J, Edelman E, Evans P, van der Heiden K, Hose R, Koo BK, Krams R, Marsden A, Migliavacca F, Onuma Y, Ooi A, Poon E, Samady H, Stone P, Takahashi K, Tang D, Thondapu V, Tenekecioglu E, Timmins L, Torii R, Wentzel J, Serruys P. Expert recommendations on the assessment of wall shear stress in human coronary arteries: existing methodologies, technical considerations, and clinical applications. Eur Heart J. 2019 Nov 1;40(41):3421-3433. doi: 10.1093/eurheartj/ehz551. No abstract available.
- Li Y, Li Z, Holck EN, Xu B, Karanasos A, Fei Z, Chang Y, Chu M, Dijkstra J, Christiansen EH, Reiber JHC, Holm NR, Tu S. Local Flow Patterns After Implantation of Bioresorbable Vascular Scaffold in Coronary Bifurcations - Novel Findings by Computational Fluid Dynamics. Circ J. 2018 May 25;82(6):1575-1583. doi: 10.1253/circj.CJ-17-1332. Epub 2018 Mar 24.
- O'Brien CC, Kolandaivelu K, Brown J, Lopes AC, Kunio M, Kolachalama VB, Edelman ER. Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants. PLoS One. 2016 Feb 23;11(2):e0149178. doi: 10.1371/journal.pone.0149178. eCollection 2016.
- Migliori S, Chiastra C, Bologna M, Montin E, Dubini G, Aurigemma C, Fedele R, Burzotta F, Mainardi L, Migliavacca F. A framework for computational fluid dynamic analyses of patient-specific stented coronary arteries from optical coherence tomography images. Med Eng Phys. 2017 Sep;47:105-116. doi: 10.1016/j.medengphy.2017.06.027. Epub 2017 Jul 12.
- Li Y, Gutierrez-Chico JL, Holm NR, Yang W, Hebsgaard L, Christiansen EH, Maeng M, Lassen JF, Yan F, Reiber JH, Tu S. Impact of Side Branch Modeling on Computation of Endothelial Shear Stress in Coronary Artery Disease: Coronary Tree Reconstruction by Fusion of 3D Angiography and OCT. J Am Coll Cardiol. 2015 Jul 14;66(2):125-35. doi: 10.1016/j.jacc.2015.05.008.
- Torii R, Stettler R, Raber L, Zhang YJ, Karanasos A, Dijkstra J, Patel K, Crake T, Hamshere S, Garcia-Garcia HM, Tenekecioglu E, Ozkor M, Baumbach A, Windecker S, Serruys PW, Regar E, Mathur A, Bourantas CV. Implications of the local hemodynamic forces on the formation and destabilization of neoatherosclerotic lesions. Int J Cardiol. 2018 Dec 1;272:7-12. doi: 10.1016/j.ijcard.2018.06.065. Epub 2018 Jun 19.
- Tenekecioglu E, Torii R, Sotomi Y, Collet C, Dijkstra J, Miyazaki Y, Crake T, Su S, Costa R, Chamie D, Liew HB, Santoso T, Onuma Y, Abizaid A, Bourantas CV, Serruys PW. The Effect of Strut Protrusion on Shear Stress Distribution: Hemodynamic Insights From a Prospective Clinical Trial. JACC Cardiovasc Interv. 2017 Sep 11;10(17):1803-1805. doi: 10.1016/j.jcin.2017.06.020. No abstract available.
- Torii R, Tenekecioglu E, Katagiri Y, Chichareon P, Sotomi Y, Dijkstra J, Asano T, Modolo R, Takahashi K, Jonker H, van Geuns R, Onuma Y, Pekkan K, Bourantas CV, Serruys PW. The impact of plaque type on strut embedment/protrusion and shear stress distribution in bioresorbable scaffold. Eur Heart J Cardiovasc Imaging. 2020 Apr 1;21(4):454-462. doi: 10.1093/ehjci/jez155.
- Papafaklis MI, Bourantas CV, Yonetsu T, Vergallo R, Kotsia A, Nakatani S, Lakkas LS, Athanasiou LS, Naka KK, Fotiadis DI, Feldman CL, Stone PH, Serruys PW, Jang IK, Michalis LK. Anatomically correct three-dimensional coronary artery reconstruction using frequency domain optical coherence tomographic and angiographic data: head-to-head comparison with intravascular ultrasound for endothelial shear stress assessment in humans. EuroIntervention. 2015 Aug;11(4):407-15. doi: 10.4244/EIJY14M06_11.
- Papafaklis MI, Bourantas CV, Farooq V, Diletti R, Muramatsu T, Zhang Y, Fotiadis DI, Onuma Y, Garcia Garcia HM, Michalis LK, Serruys PW. In vivo assessment of the three-dimensional haemodynamic micro-environment following drug-eluting bioresorbable vascular scaffold implantation in a human coronary artery: fusion of frequency domain optical coherence tomography and angiography. EuroIntervention. 2013 Nov;9(7):890. doi: 10.4244/EIJV9I7A147. No abstract available.
- Bourantas CV, Papafaklis MI, Lakkas L, Sakellarios A, Onuma Y, Zhang YJ, Muramatsu T, Diletti R, Bizopoulos P, Kalatzis F, Naka KK, Fotiadis DI, Wang J, Garcia Garcia HM, Kimura T, Michalis LK, Serruys PW. Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions. Int J Cardiovasc Imaging. 2014 Mar;30(3):485-94. doi: 10.1007/s10554-014-0374-3. Epub 2014 Jan 24.
- Thondapu V, Bourantas CV, Foin N, Jang IK, Serruys PW, Barlis P. Biomechanical stress in coronary atherosclerosis: emerging insights from computational modelling. Eur Heart J. 2017 Jan 7;38(2):81-92. doi: 10.1093/eurheartj/ehv689.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- 331221
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
The data sharing has not been decided yet. It may be considered in the future.
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .