Evaluating a Text-Prompt AI Assistant for Chest CT Scans (AI-REPORT Study) (AI-REPORT)

7 giugno 2026 aggiornato da: Shanghai Zhongshan Hospital

An Evaluation Study of a Text-Based Chest CT-Assisted Diagnostic System: A Two-stage, Multicenter, Multireader Multicase (MRMC), Self-Crossover Controlled Trial

This study aims to find out if an artificial intelligence (AI) system can help experienced radiologists write chest CT scan reports more quickly without lowering the quality of the report. Chest CT scans are common, and writing reports for them is a major part of a radiologist's job. In this trial, board-certified radiologists will interpret complex chest CT cases. For some cases, they will start with a complete draft report generated by the AI system, which they can review and edit as needed. For other cases, they will write the report from scratch without any AI help, following their usual routine. The main things we are measuring are: 1) how much time the AI draft saves, and 2) whether the final reports created with AI help are as good as or better than those written without it, as judged by other senior doctors who do not know which report came from which method. The hope is that this AI tool can make radiologists' work more efficient while maintaining high standards for patient care.

Panoramica dello studio

Descrizione dettagliata

This study investigates whether an artificial intelligence (AI) system that drafts preliminary radiology reports can help experienced chest CT radiologists work faster while maintaining or improving report quality. The trial is conducted in two sequential phases. The first phase uses a set of complex, real-world historical cases. Radiologists interpret these cases both with and without the help of the AI-generated draft (AI-report) in a controlled, crossover study design. The second phase is a prospective, real-world deployment where the same AI-report system is integrated into the clinical workflow of participating radiologists as they interpret new, incoming chest CT scans in real time. We measure the time it takes to complete reports and, through blinded evaluations by other senior doctors, assess the quality of the final reports created with and without AI assistance. The goal is to determine if this AI tool can make radiologists' work more efficient and support high-quality patient care in actual practice.

1. Detailed Description

1.1 Study Design

This is a two-phase, multicenter, multireader, multicase (MRMC) study designed to evaluate the real-world clinical utility of an AI report generation system (AI-report).

  1. Stage 1 (controlled crossover evaluation): This stage employs a retrospective, randomized, two-period crossover design. A curated set of complex historical chest CT cases, previously discussed in multidisciplinary team (MDT) meetings, is used. Each participating radiologist acts as their own control, interpreting the same cases both with and without the AI draft under controlled conditions.
  2. Stage 2 (prospective real-world deployment): This stage is a prospective, observational study. The validated AI-report system is deployed into the live clinical workflow of the participating radiologists. They use the system in real-time as they interpret new, consecutive chest CT scans from their clinical duties, allowing for evaluation in an authentic clinical environment.

1.2 Objectives

  1. Primary objectives: To evaluate the impact of the AI-report system on 1) radiologist efficiency (interpretation time) and 2) the clinical quality of finalized reports, assessed in both a controlled retrospective setting (Phase 1) and a prospective real-world setting (Phase 2).
  2. Secondary objectives: To assess the nature and clinical significance of edits made to AI drafts, and to evaluate system usability and integration into the routine reporting workflow.

1.3 Study Population

  1. Radiologist Readers: Board-certified radiologists with ≥ 3 years of independent thoracic imaging practice.
  2. Blinded Evaluators: Eleven senior clinicians from the original MDT panels that contributed the Phase 1 cases, responsible for blinded quality assessment.

1.4 Intervention

The intervention is the provision of a fully AI-generated draft radiology report (AI-report). In Phase 1, this is provided within a controlled reading platform for historical cases. In Phase 2, the system is integrated into the clinical Picture Archiving and Communication System (PACS)/Radiology Information System (RIS) to generate drafts for prospective, real-time cases.

2. Study Procedures

Phase 1 (Retrospective Crossover): The 400 historical MDT cases are used. The study involves two reading rounds with a washout period. In each round, radiologists interpret a set of cases, with the AI condition (draft provided or not) randomized and crossed over between rounds. Interpretation time is recorded, and all finalized reports are collected for blinded pairwise comparison by the evaluator panel.

Phase 2 (Prospective Deployment): Following Phase 1, the AI-report system is activated in the clinical environment for participating radiologists. During a defined prospective observation period, the system generates drafts for eligible new chest CT scans. Radiologists use these drafts in their daily work. Reporting time and the AI drafts alongside the finalized human-edited reports are collected for analysis. Report quality in this phase is assessed longitudinally and through sampling.

3. Outcome Measures

3.1 Primary Outcomes:

Efficiency: Change in median interpretation time per case with vs. without AI-report assistance (Phase 1) and the distribution of reporting times during real-world use (Phase 2).

Quality: Superiority score from blinded paired comparisons of AI-assisted vs. unassisted reports (Phase 1). Qualitative and quantitative assessment of report adequacy in the prospective cohort (Phase 2).

3.2 Secondary Outcomes:

Clinical significance of radiologist modifications to AI drafts (5-point scale).

System usability and workflow integration scores from post-study surveys.

4. Statistical Analysis

Analysis will account for the MRMC design in Phase 1 using hierarchical models. Phase 2 data will be analyzed using descriptive statistics and statistical process control methods where appropriate. The two phases will be analyzed separately to provide insights into efficacy (Phase 1) and effectiveness (Phase 2).

Tipo di studio

Interventistico

Iscrizione (Stimato)

100

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

  • Nome: Xiaodan Ye, MD, PhD
  • Numero di telefono: +86-13761459998
  • Email: yuanyxd@163.com

Backup dei contatti dello studio

Luoghi di studio

      • Shanghai, Cina
        • Reclutamento
        • Department of Radiology, Zhongshan Hospital, Fudan University
        • Investigatore principale:
          • Mengsu Zeng, MD, PhD
        • Contatto:
          • Xiaodan Ye, MD, PhD
          • Numero di telefono: +86-13761459998
          • Email: yuanyxd@163.com
        • Contatto:
      • Shanghai, Cina
        • Reclutamento
        • United Imaging Intelligence, Shanghai
        • Contatto:
        • Contatto:
        • Investigatore principale:
          • Dinggang Shen, PhD

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

Sì

Descrizione

Inclusion Criteria:

  • Active board certification and ongoing routine clinical practice as an attending radiologist
  • Independent institutional authority for chest CT image interpretation and final official diagnostic report issuance
  • A minimum of three years of post-certification clinical experience in specialized thoracic imaging
  • Legal and cognitive competence for study participation, with voluntary provision of written informed consent after full understanding of study purpose, procedures, risks and benefits

Exclusion Criteria:

  • Direct participation in the development, training or validation of the trial's evaluated AI system
  • Ongoing participation in concurrent studies with potential risks of interpretation bias, cognitive fatigue or study procedure interference (investigator-assessed)
  • Any actual or perceived conflict of interest related to the evaluated AI system or its developers that may compromise objectivity in image interpretation and diagnostic reporting

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione incrociata
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: AI-Assisted Reporting Arm
This arm involves board-certified radiologists interpreting chest CT cases using the AI system, which generates a preliminary report draft. In Phase 1 (retrospective crossover), each radiologist interprets the same set of historical cases twice: once with the AI-generated draft and once without, with order randomized and a washout period. In Phase 2 (prospective real-world deployment), radiologists use AI drafts for consecutive new chest CT scans in routine practice. The intervention is the provision of the AI-generated report draft; no other changes to standard workflow are introduced.
A clinical decision support software generates a preliminary report draft for chest CT examinations. Board-certified radiologists then finalize the AI draft.
Comparatore attivo: Standard Reporting
This arm involves board-certified radiologists interpreting chest CT cases without AI assistance, following standard workflow procedures. In Phase 1 (retrospective crossover), radiologists interpret the same set of historical cases without the AI-generated draft (order randomized with a washout period). In Phase 2 (prospective real-world deployment), this arm represents routine clinical practice where no AI drafts are provided for new chest CT scans. The control condition is standard reporting without AI assistance.
Standard chest CT reporting procedure without AI assistance. Board-certified radiologists independently interpret chest CT examinations and generate final reports following standard clinical workflow without preliminary AI-generated drafts.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Subjective report quality evaluation based on diagnostic requirements and clinical relevance
Lasso di tempo: CT reports will be distributed for external clinician scoring once all required data are available (typically ≤ 2 weeks post Primary Completion Date); the final aggregated analysis will be completed within 4 weeks post Primary Completion Date.
Quality is blindly assessed by independent clinicians using pairwise comparisons among three report types: AI-generated raw reports, human-only reports, and human-AI collaborative reports. Superior reports score 1 point, ties score 0.5.
CT reports will be distributed for external clinician scoring once all required data are available (typically ≤ 2 weeks post Primary Completion Date); the final aggregated analysis will be completed within 4 weeks post Primary Completion Date.
Significance of radiologist modifications to AI-generated reports
Lasso di tempo: CT reports will be distributed for external clinician scoring once all required data are available (typically ≤ 2 weeks post Primary Completion Date); the final aggregated analysis will be completed within 4 weeks post Primary Completion Date.
Using a 5-point ordinal scale, independent external clinicians rate the clinical significance of edits made to AI reports. Level 1 denotes minimal changes; Level 5 indicates critical corrections preventing inappropriate/delayed management. Intermediate levels (2-4) represent minor adjustments, beneficial optimizations, and significant refinements impacting diagnostic clarity or treatment selection.
CT reports will be distributed for external clinician scoring once all required data are available (typically ≤ 2 weeks post Primary Completion Date); the final aggregated analysis will be completed within 4 weeks post Primary Completion Date.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Cattedra di studio: Mengsu Zeng, MD, PhD, Department of Radiology, Zhongshan Hospital, Fudan University
  • Direttore dello studio: Dinggang Shen, PhD, United Imaging Intelligence, Shanghai
  • Direttore dello studio: Jianying Gu, MD, PhD, Department of Radiology, Zhongshan Hospital, Fudan University
  • Direttore dello studio: Dijia Wu, PhD, United Imaging Intelligence, Shanghai

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

20 giugno 2026

Completamento primario (Stimato)

31 dicembre 2026

Completamento dello studio (Stimato)

15 febbraio 2027

Date di iscrizione allo studio

Primo inviato

27 maggio 2026

Primo inviato che soddisfa i criteri di controllo qualità

7 giugno 2026

Primo Inserito (Effettivo)

9 giugno 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

9 giugno 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

7 giugno 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Termini MeSH pertinenti aggiuntivi

Altri numeri di identificazione dello studio

  • B2025-151

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .