- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07665164
Experimental Study and Training for Tanzanian Students and Health Professionals With a New Simulator for Manual Neonatal Ventilation
The goal of this clinical trial is to build capacity and assess the teaching effectiveness of a new simulator for manual neonatal ventilation in third-year nursing and clinical officer students, as well as healthcare professionals from the neonatology, gynecology, and pediatric departments.
The main questions it aims to answer are:
- Does the high-fidelity active setup of the simulator improve the percentage of target pressure achieved and the mean ventilation frequency compared to other configurations?
- How do different simulator configurations affect the training outcomes of unexperienced and experienced personnel, based on objective evaluations by expert clinicians and knowledge surveys?
- What is the self-reported usability and perceived usefulness of the different simulator configurations among the trainees? Researchers will compare a medium-fidelity passive setup, a high-fidelity passive setup with mechanical feedback, and a high-fidelity active setup with both mechanical and sensor feedback to see if the high-fidelity active configuration results in significantly higher clinical performance scores and better achievement of ventilation targets.
Participants will:
- Attend theoretical frontal lectures covering manual emergency ventilation procedures and medical simulation.
- Complete pre-training and post-training surveys to assess baseline knowledge, evaluate acquired skills, and report on the simulator's usability.
- Participate in hands-on simulator training, practicing the clinical procedure (positioning the newborn, positioning the mask, and ventilating) three times.
- Undergo a final simulation session for evaluation, where performance is objectively scored by a tutor and automatically recorded by the simulator's sensors.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Background and Rationale
Neonatal mortality in sub-Saharan Africa remains disproportionately high-26 deaths per 1,000 live births in 2023, which is 8.7 times higher than rates in Europe and North America. A significant portion of these deaths are attributable to preventable and treatable conditions occurring during birth. While skilled birth attendance can prevent up to 40% of neonatal deaths, assistance rates in sub-Saharan Africa are drastically low (40%) compared to high-income countries (90%). Consequently, strengthening the capacity of the health workforce to deliver essential newborn care is a critical priority.
Neonatal resuscitation is a complex, time-sensitive procedure. Due to severe limitations in access to advanced respiratory technologies in these regions, manual ventilation using a self-inflating bag and face mask constitutes the primary method of respiratory support. Because manual ventilation is highly operator-dependent and can cause substantial harm if performed incorrectly, technical proficiency is paramount. Simulation-based training is internationally recommended to improve provider competence, yet data on the real-world implementation, acceptability, and educational effectiveness of low-cost, high-fidelity simulators tailored to low-resource settings remains limited. This study evaluates a newly designed simulator developed specifically for the Tanzanian environment to ensure healthcare workers can acquire and maintain resuscitation skills.
Study Objectives
The specific objectives of this study are:
- to evaluate the educational effectiveness of different simulator configurations across participants with varying levels of clinical experience, using objective performance metrics collected by the simulator.
- to assess the acquisition of core manual ventilation competencies among inexperienced medical students through objective tutor evaluation and knowledge assessment.
- to assess skill reinforcement among experienced clinicians through objective tutor evaluation and knowledge assessment.
to examine user-reported usability and perceived usefulness of the simulator configurations.
Investigational Device Details
The novel, low-cost, high-fidelity neonatal simulator is designed to replicate neonatal airway anatomy and ventilation mechanics while providing objective performance feedback.
Anatomical Construction: The simulator integrates a physical manikin with internal anatomy designed to mimic the upper airways, lungs, and stomach.
Physiological Mechanics: The device mimics physiological movements, specifically the visible rise of the chest and abdomen during successful ventilation. It also features a mechanical obstruction of the esophagus if the head is not correctly placed in the required "sniffing" position.
Sensory and Digital Interface: The system incorporates pressure sensors and connects to a mobile user interface (app) that enables real-time data acquisition. The app provides the operator with real-time visual and auditory feedback regarding ventilation rate and pressure.
Study Design and Allocation
This is a prospective, randomized, and controlled study conducted at the Tosamaganga Regional Referral Hospital (TRRH) and the Tosamaganga Institute of Health and Allied Sciences (TIHAS) in the Iringa region of Tanzania.
The study population consists of two cohorts: second-year undergraduate clinical officer students at TIHAS (with no prior manual ventilation experience) and local health professionals (nursing, midwifery, and neonatal care) working at TRRH. A total of 42 students and 37 health professionals were enrolled.
Participants within each cohort were randomly assigned to one of three groups to evaluate the teaching effectiveness of different simulator configurations:
- Group A (Medium-fidelity passive setup): (14 students, 12 professionals). The simulator provides no mechanical feedback (chest rise) and no mobile user interface guidance.
- Group B (High-fidelity passive setup): (14 students, 13 professionals). The simulator provides mechanical feedback via chest and/or abdominal rise, but no mobile user interface guidance.
- Group C (High-fidelity active setup): (14 students, 12 professionals). The simulator provides full mechanical feedback alongside real-time sensor-based guidance via the mobile user interface (visual and auditory feedback).
Study Protocol and Workflow
The training course was delivered over four consecutive days (June 17-20, 2025).
- Day 1 (Theoretical Phase): Participants completed a pre-training survey to assess baseline knowledge and sociodemographic characteristics. This was followed by half-day standardized frontal lectures on manual emergency ventilation and the principles of medical simulation.
- Days 2 and 3 (Hands-on Training): Participants engaged in two hands-on sessions (one per day with a minimum 24-hour washout period). After a clinical demonstration and a 1-minute familiarization period, participants performed three 1-minute ventilation trials per session (six trials total per participant) according to their randomized group configuration. Each trial involved newborn positioning, mask placement, and target ventilation delivery.
- Day 4 (Evaluation Phase): All participants completed a standardized evaluation session using Configuration B (mimicking real clinical conditions with only chest rise feedback). Participants performed a single 1-minute ventilation trial. Performance was objectively assessed by a tutor and via simulator-derived data. Participants subsequently completed two post-training surveys assessing acquired knowledge and simulator acceptability.
Data Collection and Statistical Analysis Plan
All data were anonymized using unique numeric identifiers to link datasets across sessions. Data triangulation was achieved through three primary streams: automated simulator data, expert tutor evaluations, and self-reported surveys.
- Primary Outcome Analysis (Educational Effectiveness): The primary outcome was ventilatory performance measured by the simulator during the six training trials, specifically the mean and standard deviation (Coefficient of Variation) of the ventilation rate (target: 40 BPM) and peak inspiratory pressure (target: 25 cmH2O). Longitudinal evolution across the trials was analyzed using linear mixed-effects models, evaluating trial number, group assignment, and their interaction.
- Secondary Outcome Analysis (Knowledge and Skill acquisition/Reinforcement): Assessed via data from the final Day 4 evaluation session. Outcomes included simulator data, structured tutor performance scores (0 = poor, 0.5 = average, 1 = good), and theoretical knowledge scores (pre/post-training questionnaire). Continuous variables were analyzed using ANOVA (ANalysis Of VAriance) a (following Shapiro-Wilk testing for normality), and paired theoretical knowledge was analyzed using the Wilcoxon test.
- Tertiary Outcome Analysis (Simulator Acceptability): User-reported acceptability was measured across four Technology Acceptance Model (TAM) dimensions: Perceived Usefulness (PU), Perceived Ease-of-Use (PEU), Behavioral Intention (BI), and Fidelity of the Simulator (FS), rated on a 7-point Likert scale. Associations between these latent variables and proposed cause-effect hypotheses were tested using a partial least squares structural equation model.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Iringa
-
Tosamaganga, Iringa, Tanzania, P.O. Box 11
- Tosamaganga Regional Referral Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Third-year nursing students enrolled at the Tosamaganga Institute of Health and Allied Sciences (TIHAS).
- Third-year clinical officer students enrolled at TIHAS.
- Healthcare professionals working at Tosamaganga Hospital within the neonatology, gynecology, midwifery, and pediatrics departments.
- Individuals who voluntarily choose to attend the course.
Exclusion Criteria:
- Healthcare professionals working in fields outside of nursing, gynecology, midwifery, neonatology, and pediatrics.
- Participants who fail to complete the full training program, either by not attending all sessions or by prematurely withdrawing from the course.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Ricerca sui servizi sanitari
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Doppio
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Training with simulator configuration A
Group A used a medium-fidelity passive setup of the simulator without mechanical feedback or mobile user interface guidance.
|
Medical training on manual neonatal ventilation with phisical simulator
|
|
Sperimentale: Training with simulator configuration B
Group B used a high-fidelity passive setup of the simulator providing mechanical feedback through chest and/or abdominal rise, without mobile user interface guidance.
|
Medical training on manual neonatal ventilation with phisical simulator
|
|
Sperimentale: Training with simulator configuration C
Group C used a high-fidelity active setup of the simulator combining mechanical feedback with real-time sensor-based guidance via a mobile user interface.
|
Medical training on manual neonatal ventilation with phisical simulator
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Peak Inspiratory Pressure (PIP) (Objective 1)
Lasso di tempo: Day 2, Day 3 and Day 4
|
The primary outcome, used to assess the Objective 1, was the ventilatory performance measured by the simulator, i.e.
Peak Inspiratory Pressure (PIP) during hands-on training on Day 2 and Day 3, and the evaluation session on Day 4. In accordance with international guidelines, we considered as gold-standard a PIP of 25 cmH₂O (centimeters of water).
For each participant and trial, we computed the mean and standard deviation of PIP.
|
Day 2, Day 3 and Day 4
|
|
Ventilation Rate (Objective 1)
Lasso di tempo: Day 2, Day 3 and Day 4
|
The other primary outcome, used to assess the Objective 1, was the ventilatory performance measured by the simulator, i.e.
Ventilation Rate during hands-on training on Day 2 and Day 3, and the evaluation session on Day 4. In accordance with international guidelines, we considered as gold-standard a Ventilation Rate of 40 breaths per minute.
For each participant and trial, we computed the mean and standard deviation of the Ventilation Rate .
|
Day 2, Day 3 and Day 4
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Skill acquisition assessment (Objectives 2 and 3)
Lasso di tempo: Day 1 and day 4
|
The secondary outcomes, used to evaluate Objectives 2 and 3, were acquisition and reinforcement of manual ventilation knowledge and skills, assessed through: (1) data from the simulator sensors acquired during the final evaluation session, (2) objective tutor-based performance evaluation using a structured quantitative scoring sheet on a three-point scale (0 = poor, 0.5 = average, 1 = good, eTable 16 in Supplement 1), (3) theoretical knowledge assessment (pre and post-training true/false questionnaire).
|
Day 1 and day 4
|
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
User-reported usability and perceived usefulness (Objective 4)
Lasso di tempo: Day 4
|
The tertiary outcome used to evaluate Objective 4, were user-reported measures of simulator acceptability over the four dimensions of the TAM scale (Technology Acceptance Model): Perceived Usefulness (PU), Perceived Ease-of-Use (PEU), Behavioural Intention (BI), and Fidelity of the Simulator (FS).
The items were tailored to the characteristics of the simulator and rated on 7 points Likert scales.
A final aggregated score was obtained.
|
Day 4
|
Collaboratori e investigatori
Pubblicazioni e link utili
Pubblicazioni generali
- Maglio S, Tamirat S, Tesfaye M, Wolde M, Tognarelli S, Menciassi A, Facci E. Toward the design of a tailored training course for birth assistance: an Ethiopian experience. Pan Afr Med J. 2024 Jan 26;47:32. doi: 10.11604/pamj.2024.47.32.42221. eCollection 2024.
- Turatsinze S, Willson A, Sessions H, Cartledge PT. Medical student satisfaction and confidence in simulation-based learning in Rwanda - Pre and post-simulation survey research. Afr J Emerg Med. 2020 Jun;10(2):84-89. doi: 10.1016/j.afjem.2020.01.007. Epub 2020 Mar 9.
- Boling B, Hardin-Pierce M. The effect of high-fidelity simulation on knowledge and confidence in critical care training: An integrative review. Nurse Educ Pract. 2016 Jan;16(1):287-93. doi: 10.1016/j.nepr.2015.10.004. Epub 2015 Oct 23.
- Lee HC, Strand ML, Finan E, Illuzzi J, Kamath-Rayne BD, Kapadia V, Mahgoub M, Niermeyer S, Schexnayder SM, Schmolzer GM, Weglarz J, Williams AL, Weiner GM, Wyckoff M, Yamada NK, Szyld E. Part 5: Neonatal Resuscitation: 2025 American Heart Association and American Academy of Pediatrics Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2025 Oct 21;152(16_suppl_2):S385-S423. doi: 10.1161/CIR.0000000000001367. Epub 2025 Oct 22.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- NIMR/HQ/R.8a/Vol.IX/4983
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Periodo di condivisione IPD
Criteri di accesso alla condivisione IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Training
-
Nottingham University Hospitals NHS TrustCompletato
-
Stanford UniversityCompletatoSindrome da deficit di attenzione e iperattivitàStati Uniti
-
KTO Karatay UniversityCompletatoIctus | Riabilitazione dell'ictusTacchino
-
Dario KohlbrennerCompletato
-
University of Maryland, College ParkNational Institutes of Health (NIH); National Institute on Aging (NIA)CompletatoDisturbi percettivi uditivi | Problemi di invecchiamentoStati Uniti
-
Gia Dinh People HospitalNon ancora reclutamentoCompromissione cognitiva lieve | Prevenzione della demenza
-
AccareCompletatoSintomi comportamentali | Comportamento problema | ADHD | Problema di comportamento del bambino | ADHD Tipo prevalentemente disattento | ADHD - Tipo combinato | Problema di comportamento | Comportamento dirompente | Problema comportamentale | ADHD, tipo prevalentemente iperattivo-impulsivoOlanda
-
Université de MontréalFonds de la Recherche en Santé du QuébecCompletato
-
University Hospital, Basel, SwitzerlandCompletatoSviluppo del bambino | Studi di fattibilità | Assistenza sanitaria primaria | Forza muscolare | Allenamento di resistenza | Scuole | Servizi sanitari preventivi | Scuole / organizzazione e amministrazioneSvizzera