Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Biodegradable Magnesium Screws for Unstable Ankle Fracture Surgery

24 luglio 2026 aggiornato da: Soheil Ashkani Esfahani, Massachusetts General Hospital

Magnesium-Based Screws for Syndesmotic Fixation in Unstable Ankle Fractures

Ankle fractures are among the most common injuries that need surgery. When the broken bones make the ankle unstable, surgeons usually fix them with metal screws and plates. Metal hardware holds the bones in place well, but it can cause irritation, can loosen or break, and often has to be removed in a second surgery later.

This study looks at a different kind of screw called the RemeOs magnesium-based screw. It is made from a magnesium alloy and is designed to slowly dissolve and be absorbed by the body over about two to three years after it has done its job of holding the bone together. Because it dissolves on its own, patients may not need a second surgery to remove the hardware. These screws are authorized by the U.S. Food and Drug Administration (FDA) for use in medial malleolus ankle fractures. In this study, they are being used as an off-label indication.

The purpose of this study is to learn how well these magnesium screws work and how safe they are when used to repair unstable ankle fractures. The study will enroll at least 25 adults (ages 18 to 80) who have an unstable ankle fracture that needs surgery. All participants will have their fracture repaired with RemeOs screws as part of their normal surgical care.

After surgery, participants will be followed for 12 months. They will return for check-ups at about 6 weeks, 3 months, 6 months, and 12 months. At these visits, the study team will examine the ankle, take X-rays to see how the bone is healing and how the screws are dissolving, ask about any complications, and have participants fill out questionnaires about their ankle function and pain.

The main thing the study measures is ankle function at 12 months, scored using a standard ankle questionnaire (the Olerud-Molander Ankle Score). The study also tracks pain, healing on X-rays, how the screws break down over time, and any complications such as infection, loss of fixation, non-healing, or the need for additional surgery.

The surgery, X-rays, and follow-up visits in this study are the same care patients would receive whether or not they take part. The only research-specific parts are giving consent and filling out the study questionnaires. Taking part is voluntary and does not change the care a patient receives.

Panoramica dello studio

Stato

Non ancora reclutamento

Descrizione dettagliata

Background: A substantial proportion of operatively treated lower-extremity injuries are ankle fractures, including unimalleolar, bimalleolar, bimalleolar-equivalent, and trimalleolar patterns, often with associated distal tibiofibular syndesmotic instability. Conventional metallic fixation provides reliable initial stability but carries well-recognized drawbacks, including hardware irritation, implant breakage or loosening, and the frequent need for secondary removal procedures-particularly for syndesmotic screws. Magnesium-based biodegradable implants are designed to provide sufficient mechanical stability during fracture healing while gradually degrading, thereby eliminating routine hardware removal. RemeOs magnesium-based screws (Bioretec), composed of a magnesium-calcium-zinc alloy, medial malleolus ankle fractures and are absorbed over approximately 2 to 3 years.

Design: This is a prospective, single-arm, interventional, post-market clinical follow-up study. A minimum of 25 patients (planned enrollment of 28 to allow for attrition) will be enrolled at participating Mass General Brigham sites. Fellowship-trained orthopaedic foot and ankle surgeons will perform all procedures.

Intervention: All participants will undergo open reduction and internal fixation (ORIF) of their ankle fracture using RemeOs magnesium-based biodegradable screws for fracture fixation and/or syndesmotic stabilization, in accordance with the device Instructions for Use. RemeOs screw types (Screw LAG, Screw COM, Screw FT, and Screw LAG Solid) may be used at the surgeon's discretion. Fixation of additional fracture components may be supplemented with plates, K-wires, or non-resorbable screws as clinically indicated.

Assessments: Participants are evaluated preoperatively (baseline characteristics, radiographs, and patient-reported outcomes) and postoperatively at 6 weeks, 3 months, 6 months, and 12 months, with an optional 9-month visit if delayed healing or complications are suspected. Each follow-up includes clinical examination, radiographic assessment of healing and screw biodegradation, complication assessment, and patient-reported outcomes.

Primary outcome: Functional recovery measured by the Olerud-Molander Ankle Score (OMAS) at 12 months.

Secondary outcomes: OMAS at 3 and 6 months; radiographic fracture healing and alignment; radiographic evaluation of RemeOs screw biodegradation; complication rates (loss of fixation, infection, non-union, revision surgery); pain intensity (Visual Analog Scale); and PROMIS Physical Function and Pain Interference.

Statistical analysis: Longitudinal OMAS changes will be analyzed using a linear mixed-effects model with time as a fixed effect and subject as a random effect. Secondary outcomes will be summarized descriptively; continuous variables compared with paired t-tests or Mann-Whitney U tests as appropriate; time to revision evaluated by Kaplan-Meier analysis where applicable. A p-value < 0.05 is considered significant.

All clinical procedures (surgery, imaging, follow-up) are standard care delivered regardless of study participation; the only research-specific procedures are informed consent and completion of patient-reported outcome measures.

Tipo di studio

Interventistico

Iscrizione (Stimato)

28

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Luoghi di studio

    • Massachusetts
      • Boston, Massachusetts, Stati Uniti, 02114
        • Massachusetts General Hospital

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Descrizione

Inclusion Criteria:

  • Age 18-80 years
  • Unstable closed ankle fracture requiring surgical fixation, including unimalleolar, bimalleolar, bimalleolar-equivalent, or trimalleolar fractures
  • Fractures may be with or without syndesmotic instability
  • Willingness to follow postoperative visits and rehabilitation protocols
  • Ability to complete patient-reported outcome measures (PROMs)

Exclusion Criteria:

  • Body mass index (BMI) > 40
  • Open fractures
  • Pathologic fractures
  • Active infection at the surgical site
  • Known allergy or hypersensitivity to magnesium or implant components
  • Severe peripheral vascular disease
  • Uncontrolled diabetes mellitus
  • Prior ankle surgery on the affected limb
  • Concomitant osteochondral lesions requiring treatment
  • Neuromuscular disorders affecting the lower extremity
  • Worker's compensation cases
  • Pregnancy
  • Non-adherence concerns or inability to comply with follow-up requirements

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: RemeOs Magnesium Screw Fixation
All participants undergo open reduction and internal fixation (ORIF) of their unstable ankle fracture using RemeOs magnesium-based biodegradable screws for fracture fixation and/or syndesmotic stabilization, in accordance with the device Instructions for Use. Screw type is selected at the surgeon's discretion. Additional fracture components may be supplemented with plates, K-wires, or non-resorbable screws as clinically indicated. Participants are followed for 12 months postoperatively.
ORIF performed using RemeOs magnesium-alloy biodegradable screws (Screw LAG, Screw COM, Screw FT, and/or Screw LAG Solid) for fixation of any malleolus and/or for syndesmotic fixation where indicated, per the device Instructions for Use. The screws provide mechanical stability during healing and gradually biodegrade over approximately 2-3 years, eliminating the need for routine hardware removal.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Olerud-Molander Ankle Score (OMAS)
Lasso di tempo: 12 months
Functional recovery assessed by the Olerud-Molander Ankle Score, a patient-reported instrument scored 0 to 100, where 0 indicates totally impaired and 100 indicates no impairment. Higher scores indicate better ankle function.
12 months

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Radiographic Fracture Healing and Alignment
Lasso di tempo: 6 weeks, 3 months, 6 months, and 12 months postoperatively
Radiographic assessment of fracture union and maintenance of anatomic alignment of the ankle mortise on serial postoperative radiographs.
6 weeks, 3 months, 6 months, and 12 months postoperatively
Radiographic RemeOs Screw Biodegradation
Lasso di tempo: 3 months, 6 months, and 12 months postoperatively
Radiographic evaluation of the biodegradation behavior of the RemeOs magnesium-based screws over time, including gas formation and implant resorption.
3 months, 6 months, and 12 months postoperatively
Complication Rate
Lasso di tempo: 12 months
Proportion of participants experiencing complications, including loss of fixation, infection, non-union, and revision surgery.
12 months
Pain Intensity
Lasso di tempo: Baseline, 6 weeks, 3 months, 6 months, and 12 months postoperatively
Pain intensity measured on a Visual Analog Scale ranging from 0 (no pain) to 10 (worst imaginable pain); lower scores indicate less pain.
Baseline, 6 weeks, 3 months, 6 months, and 12 months postoperatively
PROMIS
Lasso di tempo: Baseline, 6 weeks, 3 months, 6 months, and 12 months postoperatively
ROMIS Physical Function and PROMIS Pain Interference. Both are reported as Patient-Reported Outcomes Measurement Information System (PROMIS) T-scores standardized to the US general population (mean 50, SD 10, minimum 0, maximum 100). For Physical Function, higher scores indicate a better outcome. For Pain Interference, higher scores indicate a worse outcome.
Baseline, 6 weeks, 3 months, 6 months, and 12 months postoperatively

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 agosto 2026

Completamento primario (Stimato)

1 febbraio 2029

Completamento dello studio (Stimato)

1 marzo 2029

Date di iscrizione allo studio

Primo inviato

3 luglio 2026

Primo inviato che soddisfa i criteri di controllo qualità

3 luglio 2026

Primo Inserito (Effettivo)

9 luglio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

27 luglio 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

24 luglio 2026

Ultimo verificato

1 luglio 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 2026P000142

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Descrizione del piano IPD

Individual participant data will be stored within Mass General Brigham and accessed only by IRB-approved study staff. Per the study protocol, data will not be shared outside the institution, and no biological specimens are collected.

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi