Study on the Regulation of Heart-Brain Coupling in Individuals With Depressive Tendencies Using Transcranial Magnetic Stimulation (TMS) Based on Personalized Functional Connectivity

This study focuses on individuals with depressive tendencies and investigates the regulatory effects of Transcranial Magnetic Stimulation (TMS)-guided by personalized functional connectivity mapping-on heart-brain coupling in this population, while also exploring the underlying mechanisms.Participants will undergo 3T functional magnetic resonance imaging (fMRI) scans, followed by four different types of neurostimulation: stimulation targeting individualized Dorsolateral Prefrontal Cortex (DLPFC) -Subgenual Anterior Cingulate Cortex (sgACC) functional connectivity, stimulation targeting individualized DLPFC-insula functional connectivity, standard F3 targeting, and sham stimulation. The order of these stimulation sessions will be randomized. Researchers will simultaneously record the participants' electroencephalogram (EEG) and electrocardiography (ECG) signals before and after stimulation, and will record ECG in real-time during the stimulation. The primary objective of this study is to investigate the effects of DLPFC targeting specificity on metrics such as heart-brain coupling in individuals with depressive tendencies, thereby providing a basis for future research on objective assessment and personalized interventions for depression.

Panoramica dello studio

Descrizione dettagliata

This is an exploratory, randomized, single-blind, sham-controlled, within-subject crossover study designed to investigate the regulatory effects-and underlying mechanisms-of TMS (based on individualized functional connectivity targeting) on heart-brain coupling in individuals with depressive tendencies.

Participants will undergo structural and functional neuroimaging using a 3T MRI scanner. The imaging protocol includes a structural T1-weighted scan and a functional blood-oxygen-level-dependent (BOLD) scan, used for structural image registration and functional connectivity analysis to identify TMS stimulation targets.

In this study targeting individuals with depressive tendencies, each participant will undergo four distinct stimulation conditions: individualized DLPFC-sgACC functional connectivity targeting, individualized DLPFC-insula functional connectivity targeting, standard F3 targeting, and sham stimulation. The order of these four conditions will be balanced using a Latin square design to minimize sequence effects, learning effects, and carry-over effects between conditions; a minimum interval of 5 days will be maintained between experimental sessions. High-frequency Repetitive transcranial magnetic stimulation (rTMS) will be used for the intervention, with the following parameters: stimulation frequency of 10 Hz, intensity at 90% of resting motor threshold (RMT), 2-second stimulation duration, 8-second inter-train interval, 20 pulses per train, and 45 repetitions (totaling 900 pulses), resulting in a total session duration of approximately 7.5 minutes.

Primary measures include: Phase-Amplitude Coupling (PAC), which reflects real-time information exchange between the central and autonomic nervous systems and serves as a key biomarker for the functional status of the "brain-heart axis"; TMS-induced Heart-Brain Coupling (HBC), which quantifies the rhythmic effects of TMS and provides direct evidence regarding the engagement of the prefrontal-vagal pathway; Heartbeat-Evoked Potentials (HEP), an EEG component extracted via time-locking to the ECG R-peak, which precisely reflects cortical processing of cardiac afferent signals and interoceptive function; and Heart Rate Variability (HRV), which reflects the balance of sympathetic and parasympathetic regulation. Secondary measures include EEG power spectra, fMRI data, heart rate (HR), and clinical assessment scales.

Tipo di studio

Interventistico

Iscrizione (Stimato)

60

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Luoghi di studio

    • Shaanxi
      • Xi'an, Shaanxi, Cina, 71000
        • Reclutamento
        • Xidian University
        • Contatto:

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto

Accetta volontari sani

Sì

Descrizione

Inclusion Criteria:

一、Inclusion criteria for the depressed group:

  1. Aged 18-30 years;
  2. Recent feelings of low mood and presence of depressive symptoms;
  3. Physically healthy, with no history of neurological disorders;
  4. No participation in other neuromodulation experiments within the past month;
  5. Normal hearing and normal (or corrected-to-normal) vision;
  6. PHQ-9 score > 5 and BDI-II score > 13;
  7. Avoidance of staying up late, alcohol consumption, and excessive caffeine intake prior to the experiment;
  8. Able and willing to cooperate with the completion of scale assessments. 二、Inclusion criteria for healthy participants:

(1) Aged 18-30 years; (2) No significant symptoms of depression and no history of neuropsychiatric disorders; (3) Physically healthy with no history of neurological disorders; (4) No participation in other neuromodulation experiments within the past month; (5) Normal hearing and normal (or corrected-to-normal) vision; (6) PHQ-9 score < 5 and BDI-II score < 13; (7) Avoidance of staying up late, alcohol consumption, and excessive caffeine intake prior to the experiment; (8) Able and willing to cooperate with the completion of scale assessments.

Exclusion Criteria:

  1. History of head trauma (including neurosurgery), stroke, elevated intracranial pressure, or other brain-related disorders;
  2. History of epileptic seizures or family history of epilepsy;
  3. Receipt of TMS or other neuromodulation stimulation within the past month;
  4. Presence of intracranial or internal metallic foreign bodies, electrodes made of silver or gold, or metal prostheses;
  5. Presence of devices potentially affected by TMS, such as pacemakers, drug pumps, cochlear implants, or implanted brain stimulators;
  6. Severe or recent cardiac, pulmonary, or hematopoietic system disorders, or other neurological diseases;
  7. Clinically diagnosed moderate-to-severe depressive disorder;
  8. Substance abuse, alcohol dependence, etc.;
  9. Current active suicidal ideation or suicidal behavior; Refusal to sign the informed consent form.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Scienza basilare
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione incrociata
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Personalized stimulation targeting the functional connectivity between the DLPFC-sgACC.
At this stage, participants will receive transcranial magnetic stimulation with a frequency of 10Hz and a stimulation intensity of 90% of the resting exercise threshold; Each stimulation lasts for 2 seconds, with a stimulation interval of 8 seconds; A total of 45 repeated stimuli were performed, each containing 20 pulses, for a total of 900 pulses. And the stimulation targets are located through a transcranial magnetic stimulation laser navigation system. The entire stimulation process lasts approximately 7.5 minutes.
Transcranial magnetic stimulation was applied to the dorsolateral prefrontal cortex, with individualized targeting of the region in the left dorsolateral prefrontal cortex showing the strongest negative functional correlation with the subgenual anterior cingulate cortex. The stimulation parameters were: frequency of 10 Hz, intensity of 90% of the resting motor threshold (RMT), 2-second stimulation duration, and 8-second inter-stimulus interval; each sequence comprised 20 pulses, with 45 sequences repeated for a total of 900 pulses, resulting in a total session duration of approximately 7.5 minutes.
Sperimentale: Personalized stimulation targeting DLPFC-insula functional connectivity
At this stage, participants will receive transcranial magnetic stimulation with a frequency of 10Hz and a stimulation intensity of 90% of the resting exercise threshold; Each stimulation lasts for 2 seconds, with a stimulation interval of 8 seconds; A total of 45 repeated stimuli were performed, each containing 20 pulses, for a total of 900 pulses. And the stimulation targets are located through a transcranial magnetic stimulation laser navigation system. The entire stimulation process lasts approximately 7.5 minutes.
Transcranial magnetic stimulation was applied to the dorsolateral prefrontal cortex (DLPFC); the specific insular subregion exerting the greatest negative influence on the left DLPFC was identified based on Granger causality connectivity. Stimulation parameters were as follows: frequency of 10 Hz, intensity of 90% of the resting motor threshold (RMT), a 2-second stimulation duration followed by an 8-second inter-stimulus interval, and 45 repeated sequences (each comprising 20 pulses) for a total of 900 pulses, resulting in a total session duration of approximately 7.5 minutes.
Sperimentale: Standard F3 Target Stimulation
At this stage, participants will receive transcranial magnetic stimulation with a frequency of 10Hz and a stimulation intensity of 90% of the resting exercise threshold; Each stimulation lasts for 2 seconds, with a stimulation interval of 8 seconds; A total of 45 repeated stimuli were performed, each containing 20 pulses, for a total of 900 pulses. And the stimulation targets are located through 10-20 international standard lead EEG positioning caps. The entire stimulation process lasts approximately 7.5 minutes.
Transcranial magnetic stimulation was applied to the dorsolateral prefrontal cortex, targeting the F3 site based on the international 10-20 system. The stimulation parameters were as follows: frequency of 10 Hz, intensity of 90% RMT, 2-second stimulation duration, 8-second inter-train interval, and 20 pulses per train; a total of 45 trains were delivered (900 pulses in total), with a single session lasting approximately 7.5 minutes.
Comparatore fittizio: sham stimulation
At this stage, participants will receive transcranial magnetic stimulation with a frequency of 10Hz and a stimulation intensity of 90% of the resting exercise threshold; Each stimulation lasts for 2 seconds with an interval of 8 seconds. Using a transcranial magnetic stimulation laser navigation system to locate stimulation targets, rotate the stimulation coil 90 degrees to apply false stimulation. The entire stimulation process lasts approximately 7.5 minutes.
A form of sham transcranial magnetic stimulation-either inactive or sensory-matched-designed to simulate the sensation of stimulation associated with device activation without delivering therapeutic frequencies.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
TMS-induced heart-brain coupling
Lasso di tempo: Perioperative. During the 7-minute-22-second treatment period under each stimulation condition.
By linking the stimulation rhythm to the inter-beat interval and quantifying the rhythmic effects of TMS, direct evidence is provided regarding the engagement of the prefrontal-vagal pathway.
Perioperative. During the 7-minute-22-second treatment period under each stimulation condition.
Phase-amplitude coupling
Lasso di tempo: Perioperative period. Specifically, within 10 minutes before and after each stimulus condition.
It reflects the real-time exchange of information between the central nervous system and the autonomic nervous system, serving as an important biomarker of the functional status of the "brain-heart axis."
Perioperative period. Specifically, within 10 minutes before and after each stimulus condition.
Heartbeat-evoked potentials
Lasso di tempo: Perioperative period. Specifically, within 10 minutes before and after each stimulus condition.
An EEG component extracted via time-locking to the cardiac R-peak. It precisely reflects the cerebral cortex's processing of cardiac afferent signals and interoceptive function.
Perioperative period. Specifically, within 10 minutes before and after each stimulus condition.

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
EEG power spectrum
Lasso di tempo: Perioperative period. Specifically, within 10 minutes before and after each stimulus condition.
It describes the distribution of power (energy) of EEG signals as a function of frequency. By transforming complex time-domain EEG signals into the frequency domain, it reveals energy distribution across different frequency bands, thereby helping to identify changes in the brain's functional state under various conditions.
Perioperative period. Specifically, within 10 minutes before and after each stimulus condition.
Functional connectivity of brain networks
Lasso di tempo: Baseline. During the 6-minute-30-second fMRI scan.
The analysis of functional connectivity in brain networks aims to reveal the mechanisms of coordinated activity among brain regions and dynamic individual differences, thereby providing an objective scientific basis for the diagnosis, elucidation of pathological mechanisms, and precision treatment of neuropsychiatric disorders.
Baseline. During the 6-minute-30-second fMRI scan.
Transient Assessment Scale
Lasso di tempo: Baseline and Perioperative.

Patient Health Questionnaire -9 items, with a total score range of 0-27 points. The higher the score, the more severe the depressive symptoms may be.

The Beck Depression Inventory (BDI-II) has a total score range of 0-63, with higher scores indicating more severe depressive symptoms.

The State Trait Anxiety Inventory (STAI) is a psychological assessment tool used to measure anxiety, divided into two subscales: state anxiety and trait anxiety. The total score of each subscale ranges from 20 to 80 points, with higher scores indicating higher levels of anxiety.

The Pittsburgh Sleep Quality Index (PSQI) is used to evaluate sleep quality in clinical and basic research, with a total score ranging from 0 to 21 on the PSQI scale. The higher the score, the worse the sleep quality.

Baseline and Perioperative.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 agosto 2026

Completamento primario (Stimato)

1 dicembre 2026

Completamento dello studio (Stimato)

30 dicembre 2026

Date di iscrizione allo studio

Primo inviato

30 luglio 2026

Primo inviato che soddisfa i criteri di controllo qualità

5 agosto 2026

Primo Inserito (Effettivo)

7 agosto 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

7 agosto 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

5 agosto 2026

Ultimo verificato

1 agosto 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 20260721

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .