Study of the Hemorai Vysio Wearable Device for Monitoring Changes Related to Blood Loss in Patients During and After Surgery. (VYSIO-FEASIBIL)

14 settembre 2026 aggiornato da: Hemorai Inc

Feasibility Evaluation of a Strap-Based Wearable Optical Device (Hemorai Vysio) for Monitoring Hemodynamic Trends and Early Indicators of Blood Loss in Perioperative and Postoperative Patients

The goal of this clinical trial is to learn whether the Hemorai Vysio wearable device can be used safely and feasibly to track relative changes over time in tissue oxygen, hemoglobin-related signals, blood flow, and oxygen use during and after inpatient surgery. The device does not provide absolute clinical measurements. Researchers will also explore whether changes recorded by the device occur around signs or treatments related to blood loss.

The main questions are:

  • Can the device collect usable information during and after surgery without interfering with routine care?
  • What device-related problems, such as skin irritation or discomfort, occur?
  • Do changes in the device measurements occur around changes in blood pressure, laboratory results, fluid administration, or blood transfusion?
  • How comfortable and practical is the device for participants and bedside nurses?

Participants undergoing surgery will wear the device on the upper arm or chest. Trained study staff will apply it before surgery. It will remain in place for up to 48 hours after surgery, or until discharge or earlier removal. Participants will continue to receive usual hospital monitoring and care.

Bedside nurses may also join the study and complete a short voluntary survey. Nurses may check the device position and adjust the strap for comfort. They will not interpret the device measurements or use them to make treatment decisions.

Hemorai Vysio is an investigational device. Its measurements will be analyzed for research and will not be used to guide participants' medical care. Participants are not expected to receive a direct medical benefit from taking part.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Stimato)

80

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Massachusetts
      • Burlington, Massachusetts, Stati Uniti, 01805
        • Lahey Clinic
        • Contatto:
        • Contatto:
        • Investigatore principale:
          • Elliot Servais, MD, FACS

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Bambino
  • Adulto
  • Adulto più anziano

Accetta volontari sani

Sì

Descrizione

Inclusion Criteria:

Surgical participants:

  • 18 to 85 years of age
  • Undergoing inpatient surgery with an expected overnight hospital stay
  • Capable of providing informed consent
  • No anticipated contraindications to skin-worn sensors
  • Hemodynamically stable at enrollment, with no vasopressor requirement

Nursing participants:

  • Bedside nurse caring for an enrolled surgical participant during the Vysio device-wear period
  • Capable of providing informed consent for the study-related usability survey
  • Willing to complete the voluntary usability survey

Exclusion Criteria:

Surgical participants:

  • Pregnancy; participants of childbearing potential with a positive pregnancy test before surgery
  • Prisoner
  • Cognitive impairment or inability to provide informed consent
  • Hemodynamic instability requiring vasopressors at enrollment
  • Severe dermatitis or another skin condition at the planned device application site
  • Known allergy or prior adverse reaction to silicone elastomer, thermoplastic elastomer, or components of the self-adherent elastic wrap (cotton/polyester substrate or synthetic elastic yarn)
  • Active skin breakdown, dermatitis, eczema, burns, or a surgical incision at the planned strap contact site
  • Condition compromising skin integrity such that the site would not qualify as intact skin under ISO 10993-1:2018

Nursing participants:

  • Not caring for an enrolled surgical participant during the Vysio device-wear period
  • Unable or unwilling to provide informed consent

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Fattibilità del dispositivo
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Hemorai Vysio Monitoring
Adult surgical participants will wear the investigational Hemorai Vysio device on the upper arm or chest during surgery and for up to 48 hours after surgery, or until earlier discharge, withdrawal, or clinically indicated removal. The device records research-only optical signals in parallel with standard care. Device data will be analyzed offline and will not be used to guide clinical decisions.
An investigational, non-FDA-approved strap-based wearable optical device placed on the upper arm or chest by trained study staff. It records intermittent 2-minute optical signal windows every 15 minutes during surgery and for up to 48 hours postoperatively. Research outputs include relative trends in local tissue oxygenation (StO2), hemoglobin-related signals, perfusion index (SFI), and tissue oxygen consumption (tMRO2). The device operates in parallel with standard-of-care monitoring; data are analyzed offline and are not used for clinical decisions.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Percentage of scheduled Vysio recording windows containing signal data
Lasso di tempo: From device placement before surgery through device removal, up to approximately 54 hours
For each patient participant, the number of scheduled 2-minute Vysio recording windows containing recorded signal data will be divided by the number of scheduled windows during device wear and multiplied by 100. The percentage will be summarized descriptively across participants as a measure of device-data completeness.
From device placement before surgery through device removal, up to approximately 54 hours

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Descriptive Relative Tissue Oxygenation (StO2) Trajectory by Hemorrhage-Protocol Activation Status
Lasso di tempo: From device placement before surgery through device removal, up to approximately 54 hours
Relative local tissue oxygenation (StO2) trajectories recorded by Vysio will be summarized descriptively for surgical participants with a Lahey clinical-team-defined hemorrhage-protocol activation during device wear and those without an activation (routine postoperative recovery group). Values will also be time-aligned with documented hypotension, transfusion, fluid administration, and serial hemoglobin and hematocrit results. Pearson or Spearman correlations may be calculated where appropriate. Analyses are exploratory and will not estimate diagnostic performance.
From device placement before surgery through device removal, up to approximately 54 hours
Descriptive Vysio Hemoglobin-Related Signal Trajectory by Hemorrhage-Protocol Activation Status
Lasso di tempo: From device placement before surgery through device removal, up to approximately 54 hours
Relative hemoglobin-related signal trajectories recorded by Vysio will be summarized descriptively for surgical participants with a Lahey clinical-team-defined hemorrhage-protocol activation during device wear and those without an activation (routine postoperative recovery group). These device-derived relative trends are not systemic hemoglobin concentrations. Values will be time-aligned with documented hypotension, transfusion, fluid administration, and serial laboratory hemoglobin and hematocrit results. Pearson or Spearman correlations may be calculated where appropriate. Analyses are exploratory and will not estimate diagnostic performance.
From device placement before surgery through device removal, up to approximately 54 hours
Descriptive Vysio Perfusion Index (SFI) Trajectory by Hemorrhage-Protocol Activation Status
Lasso di tempo: From device placement before surgery through device removal, up to approximately 54 hours
Relative perfusion index (SFI) trajectories recorded by Vysio will be summarized descriptively for surgical participants with a Lahey clinical-team-defined hemorrhage-protocol activation during device wear and those without an activation (routine postoperative recovery group). SFI is a relative device-derived perfusion trend and not an absolute tissue perfusion measurement. Values will be time-aligned with documented hypotension, transfusion, fluid administration, and serial hemoglobin and hematocrit results. Pearson or Spearman correlations may be calculated where appropriate. Analyses are exploratory and will not estimate diagnostic performance.
From device placement before surgery through device removal, up to approximately 54 hours
Descriptive Vysio Tissue Oxygen Consumption (tMRO2) Trajectory by Hemorrhage-Protocol Activation Status
Lasso di tempo: From device placement before surgery through device removal, up to approximately 54 hours
Relative tissue oxygen consumption (tMRO2) trajectories recorded by Vysio will be summarized descriptively for surgical participants with a Lahey clinical-team-defined hemorrhage-protocol activation during device wear and those without an activation (routine postoperative recovery group). tMRO2 is a relative device-derived trend and not an absolute calibrated metabolic rate. Values will be time-aligned with documented hypotension, transfusion, fluid administration, and serial hemoglobin and hematocrit results. Pearson or Spearman correlations may be calculated where appropriate. Analyses are exploratory and will not estimate diagnostic performance.
From device placement before surgery through device removal, up to approximately 54 hours

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Investigatori

  • Investigatore principale: Elliot Servais, MD, FACS, Lahey Clinic, Inc.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

15 ottobre 2026

Completamento primario (Stimato)

1 maggio 2027

Completamento dello studio (Stimato)

30 settembre 2027

Date di iscrizione allo studio

Primo inviato

14 settembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

14 settembre 2026

Primo Inserito (Effettivo)

17 settembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

17 settembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

14 settembre 2026

Ultimo verificato

1 settembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • Vy4-2026-01
  • 20964 (Altro numero di sovvenzione/finanziamento: Center for Advancing Point of Care Technologies (CAPCaT))
  • 1U54HL143541 (Sovvenzione/contratto NIH degli Stati Uniti)
  • 20263012 (Altro identificatore: Lahey Clinic, Inc. Institutional Review Board)
  • 2414660-1 (Altro identificatore: IRBNet / Lahey Clinic, Inc.)

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Descrizione del piano IPD

There is no current plan to make individual participant data available to researchers outside the IRB-approved study team. De-identified study data will be stored on a secure Hemorai server, with access limited to trained, IRB-approved study team members.

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi