Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Comparison of the Effect of Lung-protective Ventilation on Optic Nerve Sheath Diameter in Obese and Non-obese Patients

9 novembre 2026 aggiornato da: Gulay ERDOGAN KAYHAN, Eskisehir Osmangazi University

Comparison of the Effect of Recruitment Maneuver and Individualized Positive End-expiratory Pressure on Optic Nerve Sheath Diameter in Obese and Non-obese Patients Undergoing Laparoscopic Surgery

The gol of this prospective observational study is to evaluate the effect of recruitment maneuvers-employed as part of an intraoperative lung-protective ventilation strategy-and individualized positive end-expiratory pressure (PEEP) on intracranial pressure, as assessed by measuring the optic nerve sheath diameter, in both obese and non-obese patients undergoing laparoscopic surgery.

Panoramica dello studio

Descrizione dettagliata

Laparoscopy is widely used due to its advantages, such as less blood loss, reduced postoperative pain, and faster recovery. However, pneumoperitoneum increases thoracoabdominal pressure, which decreases venous drainage from the brain and increases cerebral blood flow and intracranial pressure (ICP). The optic nerve sheath diameter (ONSD) measurement via ultrasound is a non-invasive and reliable method for assessing ICP.

The prevalence of obesity has increased substantially over recent decades, accompanied by a growing number of obese patients undergoing laparoscopic surgery. Obesity is associated with increased intra-abdominal pressure, which may contribute to an increase in ONSD. Furthermore, the additional rise in intra-abdominal pressure induced by pneumoperitoneum may exacerbate these effects, potentially placing obese patients at greater risk of alterations in cerebral haemodynamics during laparoscopic procedures.

Atelectasis occurs in roughly 90% of all patients undergoing general anaesthesia and can persist for weeks after operation. Intraoperative lung-protective ventilation has been recommended to reduce postoperative pulmonary complications after abdominal and/or laparoscopic surgery and also in obese patients. Decreasing compliance caused by surgical/ anaesthesia factors (i.e. pneumoperitoneum, positioning, and circuit disconnect) should be treated by appropriate interventions. Individualised PEEP and alveolar recruitment manoeuvres can prevent and reverse alveolar collapse, respectively.

However, the effects of these interventions on cerebral haemodynamics, particularly ICP as assessed indirectly by ONSD measurement, remain insufficiently understood in obese and non-obese patients undergoing laparoscopic surgery.

The gol of this prospective observational study is to evaluate the effect of recruitment maneuvers and individualized PEEP- as part of intraoperative lung-protective ventilation strategy- on intracranial pressure, as assessed by measuring the optic nerve sheath diameter (ONSD), in both obese and non-obese patients undergoing laparoscopic surgery.

Tipo di studio

Interventistico

Iscrizione (Stimato)

70

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

  • Nome: Gulay Erdogan Kayhan, Prof. Dr.
  • Numero di telefono: 905332560011
  • Email: drgulayer@yahoo.com

Backup dei contatti dello studio

  • Nome: Muhammed Alpaslan Uludag, Research Assistant, MD
  • Email: muho.78@live.com

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

25 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Patients over 25 years of age
  • American Soc,ety of Anesthesiology (ASA) status I-III
  • Scheduled to undergo laparoscopic abdominal surgery
  • With an expected pneumoperitoneum duration of ≥1 hour

Exclusion Criteria:

  • Patients with ocular disease
  • Patients who have undergone cranial or ocular surgery
  • Patients with a history of laparotomy
  • Individuals with bullous lung disease
  • Patients with uncontrolled chronic obstructive lung disease
  • Patients with hemodynamic instability or decompensated heart failure
  • Patients who require conversion to an open surgical procedure for any reason

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: Non randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Altro: Group O

Obese patients with BMI ≥ 30 kg/m²

Following intubation and desufflation, an incremental alveolar recruitment maneuver (ARM) will be performed, in which the driving pressure is kept constant while the PEEP value is increased in a stepwise manner. The ARM will be performed in pressure control mode, maintaining pressure at a steady driving pressure with increments in PEEP until a peak pressure is achieved (35-40 cmH2) with a preestablished maximum PEEP. This will be maintained long enough to reopen the alveoli (5---10 breaths), and then pressure is reduced in a stepwise manner until the ideal PEEP is achieved (this being the PEEP level that produces the best Cdyn at the lowest driving pressure for a particular tidal volume setting)

ONSD will be measured at a standard level of 3 mm behind using a lineer ultrasound transducer. The measurements will be performed by an anesthesiologist experienced in ONSD measurement. The eyes will be covered with drapes; subsequently, using an ultrasound-compatible gel, measurements of both of the patient's eyes will be taken in a transverse and a sagittal plane. The mean of these measurements will then be calculated to determine the ONSD value.

Altro: Group N

Non-obese patients

Following intubation and desufflation, an incremental alveolar recruitment maneuver (ARM) will be performed, in which the driving pressure is kept constant while the PEEP value is increased in a stepwise manner. The ARM will be performed in pressure control mode, maintaining pressure at a steady driving pressure with increments in PEEP until a peak pressure is achieved (35-40 cmH2) with a preestablished maximum PEEP. This will be maintained long enough to reopen the alveoli (5---10 breaths), and then pressure is reduced in a stepwise manner until the ideal PEEP is achieved (this being the PEEP level that produces the best Cdyn at the lowest driving pressure for a particular tidal volume setting)

ONSD will be measured at a standard level of 3 mm behind using a lineer ultrasound transducer. The measurements will be performed by an anesthesiologist experienced in ONSD measurement. The eyes will be covered with drapes; subsequently, using an ultrasound-compatible gel, measurements of both of the patient's eyes will be taken in a transverse and a sagittal plane. The mean of these measurements will then be calculated to determine the ONSD value.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Optic nerve sheath diameter (ONSD)
Lasso di tempo: Perioperative/Periprocedural (t0-after anesthesia induction and entubation)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Perioperative/Periprocedural (t0-after anesthesia induction and entubation)
Optic nerve sheath diameter (ONSD)
Lasso di tempo: Perioperative/Periprocedural (t1- following the recruitment maneuver and the adjustment of the individualized PEEP value)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Perioperative/Periprocedural (t1- following the recruitment maneuver and the adjustment of the individualized PEEP value)
Optic nerve sheath diameter (ONSD)
Lasso di tempo: Perioperative/Periprocedural (t2- at the 30th minute of pneumoperitoneum)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Perioperative/Periprocedural (t2- at the 30th minute of pneumoperitoneum)
Optic nerve sheath diameter (ONSD)
Lasso di tempo: Perioperative/Periprocedural (t3 - after desufflation)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Perioperative/Periprocedural (t3 - after desufflation)
Optic nerve sheath diameter (ONSD)
Lasso di tempo: Perioperative/Periprocedural (t4- following a subsequent recruitment maneuver)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Perioperative/Periprocedural (t4- following a subsequent recruitment maneuver)
Optic nerve sheath diameter (ONSD)
Lasso di tempo: Perioperative/Periprocedural (t5- at the 30th minute in the recovery room)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Perioperative/Periprocedural (t5- at the 30th minute in the recovery room)

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
MAP
Lasso di tempo: Perioperative (Noninvasive mean arterial pressure will be recorded at the times when ONSD measurement is performed)

Noninvasive mean arterial pressure (mmHg)

Perioperative (Noninvasive mean arterial pressure will be recorded at the times when ONSD measurement is performed)
HR
Lasso di tempo: Perioperative (Heart rate will be recorded at the times when ONSD measurement is performed)

Heart rate (beat/min)

Perioperative (Heart rate will be recorded at the times when ONSD measurement is performed)
etCO2
Lasso di tempo: Perioperative (End-tidal carbon dioxide levels will be recorded at the times when ONSD measurement is performed)

End-tidal carbon dioxide levels (mmHg)

Perioperative (End-tidal carbon dioxide levels will be recorded at the times when ONSD measurement is performed)

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Airway pressures during mechanical ventilation
Lasso di tempo: Perioperative (Ppeak, Pplato, Driving pressure (∆P), PEEP levels will be recorded at the times when ONSD measurement is performed)

Ppeak, Pplato, Driving pressure (∆P), PEEP levels (cmH20) will be recorded from the sama ventilation monitor screen

Perioperative (Ppeak, Pplato, Driving pressure (∆P), PEEP levels will be recorded at the times when ONSD measurement is performed)
Postoperative complications
Lasso di tempo: PONV will be questioned at the 24th hours

Postoperative nause and vomiting (PONV)

PONV will be questioned at the 24th hours
Postoperative complications
Lasso di tempo: Headache will be questioned at the 24th hours

Headache

Headache will be questioned at the 24th hours
Postoperative complications
Lasso di tempo: Visual disturbance will be questioned at the 24th hours

Visual disturbance

Visual disturbance will be questioned at the 24th hours

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 dicembre 2026

Completamento primario (Stimato)

1 novembre 2027

Completamento dello studio (Stimato)

1 novembre 2027

Date di iscrizione allo studio

Primo inviato

3 novembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

9 novembre 2026

Primo Inserito (Effettivo)

16 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

16 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

9 novembre 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi